Abdulmujeeb Olatomiwa Oladeji
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Abdulmujeeb Olatomiwa Oladeji has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Abdur-Roqeeb Olamide Ismail
Department of Medicine, Ladoke Akintola University of Technology, Ogbomoso, Nigeria
2 shared publications - Emmanuel Oyedeji Oyetola
Ladoke Akintola University of Technology, Ogbomoso, Nigeria
2 shared publications - Habiblah Ayomide Jagunmolu
Ladoke Akintola University of Technology, Ogbomoso, Nigeria
2 shared publications - Samuel Oyeponle Oyelude
Ladoke Akintola University of Technology, Ogbomoso, Nigeria
2 shared publications - Toluwanimi Oladele Idowu
Department of Medicine, Ladoke Akintola University of Technology, Ogbomoso, Nigeria
2 shared publications - Abdulhafiz Ashiru
Ulster Hospital, Dundonald, Northern Ireland, Belfast, UK
1 shared publication
Latest Publications
- 24 August 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 877
Robotic-assisted total knee arthroplasty for severe fixed valgus deformity: a systematic review of alignment restoration, soft tissue balancing strategies, and clinical outcomes
Managing moderate-to-severe fixed valgus deformities in total knee arthroplasty (TKA) is technically demanding due to lateral compartment bony hypoplasia, contracted lateral soft tissues, and medial collateral ligament laxity. While conventional workflows often require extensive manual ligamentous releases, robotic-assisted TKA (RA-TKA) offers real-time digital gap balancing. This systematic review evaluates the clinical and radiographic efficacy of RA-TKA specifically isolating the moderate-to-severe fixed valgus morphotype. A systematic search of PubMed, Scopus, Google Scholar, and Cochrane CENTRAL was conducted from 27th of May 2026 to 1st of June 2026. The study was prospectively registered on PROSPERO, and clinical studies evaluating primary RA-TKA for fixed valgus deformities (at least 100, or Krackow Type II or III) were included. Methodological quality was assessed using the ROBINS-I tool and JBI Critical Appraisal Checklist. Thirteen studies comprising 1,787 robotic-assisted TKAs were included. Improvements from preoperative to postoperative coronal alignment were consistently achieved, with mean postoperative hip-knee-ankle angles restored to within 10-30 of surgical targets and low outlier rates (<20% across robotic cohorts compared to up to 42.3% in manual controls). Functional Alignment cohorts consistently achieved 0% manual soft-tissue release rate. Conversely, Mechanical Alignment (MA) cohorts required selective lateral releases (primarily the iliotibial band and popliteus tendon) in 38.5% to 71.4% of cases. Robotic-assisted TKA is a safe and highly precise tool for managing the complex valgus morphotype. It provides excellent coronal alignment restoration and facilitates a major de-escalation of surgical trauma, allowing surgeons to achieve stability with standard, lower-constraint implants. Level of Evidence: Level IV
- 24 August 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 877
Robotic-assisted total knee arthroplasty for severe fixed valgus deformity: a systematic review of alignment restoration, soft tissue balancing strategies, and clinical outcomes
Managing moderate-to-severe fixed valgus deformities in total knee arthroplasty (TKA) is technically demanding due to lateral compartment bony hypoplasia, contracted lateral soft tissues, and medial collateral ligament laxity. While conventional workflows often require extensive manual ligamentous releases, robotic-assisted TKA (RA-TKA) offers real-time digital gap balancing. This systematic review evaluates the clinical and radiographic efficacy of RA-TKA specifically isolating the moderate-to-severe fixed valgus morphotype. A systematic search of PubMed, Scopus, Google Scholar, and Cochrane CENTRAL was conducted from 27th of May 2026 to 1st of June 2026. The study was prospectively registered on PROSPERO, and clinical studies evaluating primary RA-TKA for fixed valgus deformities (at least 100, or Krackow Type II or III) were included. Methodological quality was assessed using the ROBINS-I tool and JBI Critical Appraisal Checklist. Thirteen studies comprising 1,787 robotic-assisted TKAs were included. Improvements from preoperative to postoperative coronal alignment were consistently achieved, with mean postoperative hip-knee-ankle angles restored to within 10-30 of surgical targets and low outlier rates (<20% across robotic cohorts compared to up to 42.3% in manual controls). Functional Alignment cohorts consistently achieved 0% manual soft-tissue release rate. Conversely, Mechanical Alignment (MA) cohorts required selective lateral releases (primarily the iliotibial band and popliteus tendon) in 38.5% to 71.4% of cases. Robotic-assisted TKA is a safe and highly precise tool for managing the complex valgus morphotype. It provides excellent coronal alignment restoration and facilitates a major de-escalation of surgical trauma, allowing surgeons to achieve stability with standard, lower-constraint implants. Level of Evidence: Level IV
- Open Access
- 22 August 2026
- Published by Springer Nature in BMC Pediatrics
- Vol. 26 (1)
Congenital diaphragmatic hernia in Sub-Saharan Africa: a scoping review of presentation, management strategies, and outcomes
- 22 August 2026
- Published by Springer Nature in BMC Pediatrics
- Vol. 26 (1)
Open AccessCongenital diaphragmatic hernia in Sub-Saharan Africa: a scoping review of presentation, management strategies, and outcomes