Levita Valeriant
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Levita Valeriant has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Arndt-Peter Schulz
BG Klinikum Hamburg, Hamburg, Germany
1 shared publication - Matthias Münch
Centre for Clinical Research, BG Klinikum Hamburg, 21033 Hamburg, Germany
1 shared publication - Nicholas Bishop
Department of Medical Technology, Faculty of Life Sciences, Hamburg University of Applied Sciences (HAW Hamburg), 21033 Hamburg, Germany
1 shared publication - Tobias Barth
Centre for Clinical Research, BG Klinikum Hamburg, 21033 Hamburg, Germany
1 shared publication
Latest Publications
- Open Access
- 28 August 2026
- Published by MDPI AG in Biomechanics
- Vol. 6 (3) , 78
Realistic Boundary Conditions in Testing Diaphyseal Femoral Implants
Background: Considerable variation exists in the proximal and distal fixture designs used in biomechanical testing of diaphyseal femoral implants. In most of them a load is applied to the femoral head, but muscle forces are rarely represented, so bending of the diaphysis is unphysiologically high. Methods: This study investigated twelve testing configurations reported in the literature using finite element and analytical models of the femoral diaphysis and a lateral fixation plate. The models differed in proximal and distal displacement constraints, femoral orientation, and load application. Internal force distributions, as well as bone and implant stresses and bone strains, were calculated for each configuration. Results: Common experimental conditions, in which the load is applied to the femoral head, generally produced high bending moments, resulting in, what we interpret to be, unrealistically high bone and implant stresses and bone strains. In contrast, axial loading along the femoral shaft generated substantially lower bending, which we propose to be more physiological, particularly in two such cases with reduced rotational constraint. Conclusions: Their constant bending distribution should improve reproducibility and their implementation should provide a practical approach to biomechanical testing of diaphyseal femoral implants.
- 28 August 2026
- Published by MDPI AG in Biomechanics
- Vol. 6 (3) , 78
Open AccessRealistic Boundary Conditions in Testing Diaphyseal Femoral Implants
Background: Considerable variation exists in the proximal and distal fixture designs used in biomechanical testing of diaphyseal femoral implants. In most of them a load is applied to the femoral head, but muscle forces are rarely represented, so bending of the diaphysis is unphysiologically high. Methods: This study investigated twelve testing configurations reported in the literature using finite element and analytical models of the femoral diaphysis and a lateral fixation plate. The models differed in proximal and distal displacement constraints, femoral orientation, and load application. Internal force distributions, as well as bone and implant stresses and bone strains, were calculated for each configuration. Results: Common experimental conditions, in which the load is applied to the femoral head, generally produced high bending moments, resulting in, what we interpret to be, unrealistically high bone and implant stresses and bone strains. In contrast, axial loading along the femoral shaft generated substantially lower bending, which we propose to be more physiological, particularly in two such cases with reduced rotational constraint. Conclusions: Their constant bending distribution should improve reproducibility and their implementation should provide a practical approach to biomechanical testing of diaphyseal femoral implants.