JHJiuzhou He

Jiuzhou He

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jiuzhou He has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Numerical Investigation of the Shear Performance of Large-Diameter Hinged-Bolt Connectors in Steel–UHPC Composite Beams

    by Shiqiang Feng, Yong Yang, Xin Chen, Yicong Xue, Yunlong Yu, Huayu Li, Jiuzhou He

    Large-diameter hinged-bolt connectors markedly reduce the early slip caused by bolt-to-hole clearance in conventional bolted connectors while avoiding welding-related problems associated with large-diameter headed studs in steel–ultra-high-performance concrete (UHPC) composite beams. However, their internal load-transfer mechanism cannot be directly quantified through push-out tests. A three-dimensional nonlinear finite element model was developed and validated against twelve push-out specimens. For the UHPC specimens, the model provided quantitatively reliable predictions of peak shear resistance and ultimate slip, and accurately captured the governing bolt shear fracture failure mode. The validated model was used to quantify the distributions of shear force, axial force, and bending moment along the hinged bolt. After excluding the specimens strongly affected by concrete crushing or severe steel-flange deformation, the remaining specimens exhibited maximum bolt shear forces of approximately 68–83% of the corresponding pure-shear resistance and maximum axial forces of approximately 10–20% of the pure-tension resistance. For the investigated specimens, the effective concrete-reaction length averaged 1.53 times the smooth-shank diameter. Parametric analyses showed that increasing the bolt grade from 4.6 to 12.9 raised the peak shear resistance by approximately 131%, while progressively shifting the governing response from bolt shear fracture toward UHPC crushing. Bolt aspect ratios of 2.6–4.0 produced similar bolt-fracture-controlled responses, whereas an aspect ratio of 1.0 caused UHPC pry-out. Increasing the steel grade from Q355 to Q690 and the longitudinal bolt spacing from four to seven nominal bolt diameters raised the peak resistance by only 7.3% and 4.0%, respectively. These findings provide a mechanical basis for the rational design of large-diameter hinged-bolt connectors.

  • Open Access

    Preliminary Experimental Study on the Flexural Behavior of High-Strength Castellated Steel–UHPC Composite Beams with Hinged-Bolt Shear Connectors

    by Shiqiang Feng, Yong Yang, Xin Chen, Yicong Xue, Yunlong Yu, Jiuzhou He, Yang Chen, Dongde Sun

    High-strength steel–ultra-high-performance concrete (UHPC) composite beams provide an efficient solution for lightweight and high-capacity building structures. This study presents a preliminary experimental investigation on the flexural behavior of three high-strength castellated steel–UHPC composite beam configurations employing hinged-bolt shear connectors. This connector type had previously been validated only at the component level and was applied here for the first time in high-strength castellated steel–UHPC composite beams. The three beams were tested under positive bending: a reference specimen with a full-depth cast-in-place UHPC slab and dispersed connectors (CC-DHB), a prefabricated specimen with a C100 precast slab, dispersed connectors, and local UHPC connection regions (PC-DHB), and a prefabricated specimen with a C100 precast slab, grouped connectors, and local UHPC connection regions (PC-GHB). The failure mode, load–deflection response, ductility, interface slip, strain distribution, and flexural resistance were evaluated. The results showed that all specimens exhibited flexure-dominated failure, characterized by the yielding of the steel girder and tensile reinforcement occurring first, followed by concrete crushing near the loading region. A key finding was that, although UHPC was used only in the local connection regions of the two prefabricated configurations, their peak flexural resistances were only 4.5% and 2.5% lower than that of the full-depth cast-in-place UHPC reference beam, indicating that the prefabricated beams substantially reduced UHPC use while retaining nearly the same ultimate flexural resistance as the reference beam. However, their initial stiffness and ductility factors decreased by up to 17%, while their cracking load decreased by approximately 50%. Compared with specimen PC-GHB, the initial stiffness and ductility of specimen PC-DHB increased by approximately 5%. The maximum measured interface slip before the peak load was less than 3 mm for all specimens. A preliminary sectional plastic-resistance method was also developed, and the calculated-to-tested resistance ratios ranged from 1.06 to 1.08. Further validation is required for different connector spacings, web-opening layouts, slab configurations, and shear connection degrees.