Latest Publications

  • Open Access

    Seven Questions for EN 1992-4

    by Yves De Lathouwer

    EN 1992-4:2018 is the European standard for the design of fastenings in concrete. Its resistance models rest on an extensive experimental basis, but several of its load-distribution rules, interaction rules and modification factors are not derived from that basis, or apply it beyond the conditions in which it was obtained. This paper reviews seven such provisions. Three have been examined in detail in earlier studies by the author and are summarised here: the default assumption of cracked concrete and the undefined depth of its 0.3 mm reference crack; the pry-out factor k8, which links pry-out to tension resistance by a factor of 1 or 2 where mechanics and test databases indicate about 2.5 to 4; and the concrete edge verification of multi-row groups, in which only the row closest to the edge is effective, so that adding anchors can lower the verified resistance by 36 to 58 %. Four further provisions are examined here for the first time, with worked examples computed with the formulae of the standard: (i) the tension–shear interaction of Table 7.3, which combines the most utilised tension mode and the most utilised shear mode with one exponent whatever the mechanisms involved; (ii) the splitting provisions of §7.2.1.7, where the only exemption for uncracked concrete requires designing for cracked concrete, so that for an M12 wedge-anchor group the verified resistance falls from 63.1 kN to 32.2 kN with the splitting check, or to 40.0 kN plus 138 mm² of reinforcement without it; (iii) the constant factor ψ90°,V = 2.0 for shear parallel to an edge, which a resistance-dependent expression of the fib type places between 2.4 and 1.1 for the same anchor as c1 grows from 60 to 200 mm, so that the constant is unconservative by up to 87 % at larger edge distances; and (iv) the shell-spalling factor ψre,N, which reduces cone, bond and, through k8, pry-out resistance by up to 30 % because reinforcement is present, and has no counterpart in ACI 318. The provisions are classified by the nature of the departure — contradiction of tests, inconsistency with a parallel code, internal logical inconsistency — and a research programme is proposed for each. The review refers to the first-generation text; the second-generation Eurocodes were not available to the author. Also posted on Preprints.org: 10.20944/preprints202609.2638.v1.

  • Open Access

    Anchor Theory, Rebar Theory and the Missing Bridge

    by Yves De Lathouwer

    Post-installed bonded steel in concrete is designed today by at least six methods: the concrete capacity method of EN 1992-4, the anchorage and lap rules of EN 1992-1-1 with EAD 330087, strut-and-tie models, EOTA TR 069 with EAD 332402, the cover-dependent anchorage of EN 1992-1-1:2023 with its new provisions for post-installed bars, and manufacturer methods; in North America, ACI 318 offers the same split between anchoring (Chapter 17) and development length (Chapter 25). The methods rest on different mechanical models and reach opposite conclusions on the same question. The anchor methods verify the concrete cone for every fastener up to 20 diameters; the reinforcement methods never verify it. A ribbed bar and a threaded rod of equal strength, in the same hole and the same mortar, may therefore be designed to differ by a factor of two to ten, and the boundary between the two treatments is drawn by the name of the steel element rather than by any stated criterion. This paper sets out each method with its rationale, its qualification basis, its field of application and its limits, and identifies the common mechanics beneath them. The concrete cone is a property of the load path: it forms where the tension of the element must return through concrete in tension, and it is absent where that tension is closed by a lap with existing reinforcement, by a compression strut to a proven node, or by hanger reinforcement. The reinforcement methods may ignore the cone because their field of application consists of closed load paths; they are misused, and the cone returns, when they are applied to open ones such as beam-to-column moment connections with straight bars, for which a worked example gives a cone resistance of 18% of the yield force of the bars. Independently of closure, the cone ceases to govern a single fastener at 11 to 18 diameters against steel and 4 to 18 against bond, but never ceases to govern a dense row by depth alone. The paper identifies the bridges that already exist between the two families (TR 069 with ψM,N, EN 1992-4 7.2.1.2(2)e, supplementary reinforcement, rebars designed as fasteners, strut-and-tie proof of nodes) and proposes the one that is missing: an element-neutral rule built on a closure ratio λ and a dominance ratio η, written as a single verification NEd ≤ min[NRd,s; NRd,b; NRd,c·ψM,N/(1 − λ)] whose end points are EN 1992-4 (λ = 0) and EN 1992-1-1 (λ ≥ 1). Under it a threaded rod and a bar in the same position give the same result; the steel element enters only through bond qualification and, for moment and seismic connections, a ductility requirement. A decision schema summarises the use of every method. A seismic example computed with the author’s software (AAS, ARS) shows the stakes: for one metre of Ø12 bars at 150 mm the anchor route gives 161 kN, 39% of the capacity-design force, while the rebar route anchors the bars for that force with 651 mm of embedment. Also posted on Preprints.org: 10.20944/preprints202610.0283.v1.

  • Open Access

    Anchor Theory, Rebar Theory and the Missing Bridge: A Map of the Design Methods for Post-Installed Bonded Steel in Concrete—Why a Reinforcing Bar May Ignore the Concrete Cone, Why a Threaded Rod May Not, and a Rule for When the Cone Is Relevant

    by Yves De Lathouwer

    Post-installed bonded steel in concrete is designed today by at least six methods: the concrete capacity method of EN 1992-4, the anchorage and lap rules of EN 1992-1-1 with EAD 330087, strut-and-tie models, EOTA TR 069 with EAD 332402, the cover-dependent anchorage of EN 1992-1-1:2023 with its new provisions for post-installed bars, and manufacturer methods; in North America, ACI 318 offers the same split between anchoring (Chapter 17) and development length (Chapter 25). The methods rest on different mechanical models and reach opposite conclusions on the same question. The anchor methods verify the concrete cone for every fastener up to 20 diameters; the reinforcement methods never verify it. A ribbed bar and a threaded rod of equal strength, in the same hole and the same mortar, may therefore be designed to differ by a factor of two to ten, and the boundary between the two treatments is drawn by the name of the steel element rather than by any stated criterion. This paper sets out each method with its rationale, its qualification basis, its field of application and its limits, and identifies the common mechanics beneath them. The concrete cone is a property of the load path: it forms where the tension of the element must return through concrete in tension, and it is absent where that tension is closed by a lap with existing reinforcement, by a compression strut to a proven node, or by hanger reinforcement. The reinforcement methods may ignore the cone because their field of application consists of closed load paths; they are misused, and the cone returns, when they are applied to open ones such as beam-to-column moment connections with straight bars, for which a worked example gives a cone resistance of 18% of the yield force of the bars. Independently of closure, the cone ceases to govern a single fastener at 11 to 18 diameters against steel and 4 to 18 against bond, but never ceases to govern a dense row by depth alone. The paper identifies the bridges that already exist between the two families (TR 069 with ψM,N, EN 1992-4 7.2.1.2(2)e, supplementary reinforcement, rebars designed as fasteners, strut-and-tie proof of nodes) and proposes the one that is missing: an element-neutral rule built on a closure ratio and a dominance ratio , written as a single verification N_Ed ≤ min[N_Rd,s; N_Rd,b; N_Rd,c M,N/(1 − )] whose end points are EN 1992-4 ( = 0) and EN 1992-1-1 ( ≥ 1). Under it a threaded rod and a bar in the same position give the same result; the steel element enters only through bond qualification and, for moment and seismic connections, a ductility requirement. A decision schema summarises the use of every method. A seismic example computed with the author’s software (AAS, ARS) shows the stakes: for one metre of Ø12 bars at 150 mm the anchor route gives 161 kN, 39% of the capacity-design force, while the rebar route anchors the bars for that force with 651 mm of embedment.

  • Open Access

    Does the Front Row Carry It All? Concrete Edge Failure of Multi-Row Anchor Groups in EN 1992-4

    by Yves De Lathouwer

    EN 1992-4 verifies concrete edge failure of a multi-row anchor group loaded in shear towards a free edge by assuming that only the row closest to the edge is effective and that it carries the whole shear load. The consequence is paradoxical: the verified resistance does not grow when rows are added behind the front row, it falls when a row is added in front of existing anchors, and it rises when the holes of the front row are deliberately slotted so that those anchors carry nothing. For a 3 × 3 group of M12 wedge anchors (s = 150 mm, hef = 70 mm, C25/30, h = 250 mm) at c1 = 75, 100 and 150 mm, the code gives 31, 39 and 56 kN (uncracked), while the same anchors with the front row slotted give 73, 78 and 87 kN. The paper examines this rule with three tools: the EN 1992-4 calculation, the equal-share method implemented in the AAS anchor-design software, and a three-dimensional nonlinear finite-element analysis in Code_Aster with a regularised damage model for concrete, elastic steel shanks and a rigid fixture. Without hole clearance every row is active up to failure: the group resists 5.4, 3.9 and 2.9 times the load of the front row acting alone, where EN 1992-4 assumes 1.0. Removing the front row does not increase the computed resistance, so adding anchors near the edge does not weaken the group; with a hole clearance that lets the front row fail first, the group still reaches 92 to 94 % of its resistance at a larger displacement. The equal-share (AAS) method is close to this behaviour; a verification rule is proposed that keeps the equal share and adds a check of the global break-out body behind the back row. It is conservative by a nearly constant factor of 1.4 to 1.6 with respect to the normalised finite-element results, against 2.9 to 4.7 for the present rule.

  • Open Access

    The Pry-Out Factor: A Critical Re-examination of the Link Between Tension and Pry-Out Resistance in EN 1992-4

    by Yves De Lathouwer

    EN 1992-4:2018 does not verify concrete pry-out on its own terms. It sets the pry-out resistance of a fastener at a multiple k8 of its tension resistance: the concrete cone resistance for mechanical fasteners, and the smaller of the cone resistance and the combined pull-out resistance for bonded fasteners, with default values k8 = 1 or 2. This paper examines that factor. For the bond term, clause 7.2.2.4(1) names the mechanism itself: pull-out under a tension force induced by the shear. With k8 = 2 the code therefore assumes that half of the shear reaches the bond as tension. The mechanics of a laterally loaded anchor in concrete, with local crushing at the mouth of the hole, a pivot at 1.5d–2d and a tilted shank, give an induced tension of 14–27 % of the shear for plastic tilts of 8°–15°, so the factor between bond resistance and the shear it can resist is about 4 to 7. A credibility criterion shows that shear-induced pull-out can precede steel shear failure only below a bond-strength threshold that depends on hef/d alone; in 76 single-anchor configurations within the admitted embedment range the bond term governed 21 times under the code and never with a factor of 4. For the concrete term, the largest recent test database shows the code to be conservative, with mean test-to-prediction ratios of 1.27 for single anchors and 1.63 for groups, corresponding to an effective factor of about 2.5 and 3.3, and product assessments already grant k8 up to 2.9. The group rules reduce the resistance with overlap factors derived for tension, although for anchors in line with the load the rear anchor compresses the concrete in which the front anchor’s crater must form. The provisions are also inconsistent: the same Hilti HUS4 screw is checked without its pull-out resistance as a mechanical fastener and with it as a bonded screw, and the mortar is credited for embedment depth but not for diameter. A separate factor kp on the bond term and a test-based recalibration of k8 for single anchors and groups are proposed, with a test programme to confirm them.

  • Open Access

    Where Are the Cracks in the Definition of “Cracked Concrete”?

    by Yves De Lathouwer

    EN 1992-4 permits a fastening to be designed for uncracked concrete only where the absence of cracking can be demonstrated over the whole anchorage depth; in the absence of that demonstration the concrete is taken as cracked. In practice the demonstration is rarely attempted, and the cracked assumption has hardened into a near-universal default. The design consequence is substantial: the characteristic concrete cone resistance in cracked concrete is approximately 70 % of the uncracked value, and for bonded fasteners the declared bond resistance in cracked concrete is commonly one half to two thirds of the uncracked value. This paper examines whether the default is proportionate to the evidence supporting it. Five observations are developed. First, both EN 1992-1-1 and EN 1992-4 define the reference crack by its width (0.3 mm) and are silent on its depth, so a shallow surface crack and a crack traversing the full section are treated identically, although their effect on an embedded fastener is not. Second, the guidance issued by the British Board of Agrément (Guidance No. 39) already frames the question probabilistically — as a joint probability involving the location of the crack, the variability of imposed load in time and space, and the independence of the fastening load from that imposed load — a framing that the Eurocode’s binary classification discards. Third, a real flexural crack is wedge-shaped: widest at the tensile face and closing to zero at its tip, so a crack of 0.3 mm at the surface is necessarily narrower at every depth below it, whereas the qualification specimen is cracked to approximately uniform width through the member. The two geometries are mutually exclusive. Fourth, the action required to open a crack of 0.3 mm has never been related to the depths at which fasteners are installed; worked examples show that the reference crack corresponds to a steel stress of 300 to 350 N/mm², some 70 to 80 % of design yield, so that a slab in ordinary service carries surface cracks of 0.14 to 0.23 mm and engages, over a typical anchorage, a mean width under half the value at which the fastener was assessed. For a fastening loaded purely in shear the fastener contributes nothing to opening the crack at all, and none of the three checks that can then govern draws on any parameter obtained from testing in cracked concrete. Fifth, recent experimental work on the contribution of supplementary and surface reinforcement indicates that the cone model underlying the classification omits a resistance mechanism that is systematically present in real members. A worked example from a current European Technical Assessment shows the same pattern in the pry-out check, where the declared product-specific factor places the pry-out resistance permanently above the fastener’s own steel resistance, so that the failure mode the factor quantifies cannot be produced by the product it describes. The paper also notes, as a limitation of the evidence base rather than as an allegation, that the great majority of anchor testing is funded by manufacturers whose commercial interest is served by the more onerous classification. In place of the binary default a graded framework of factors is proposed, ordered so that the condition of the member decides whether a crack of the reference kind can be present at all, the geometry of the anchorage decides how much of it the fastener would engage, and the properties of the connection modify probability and consequence without ever deciding the classification on their own. Its boundaries are stated explicitly: seismic design, and any case of genuine doubt, remain cracked.

  • Open Access

    Does the Front Row Carry it All? Concrete Edge Failure of Multi-row Anchor Groups in EN 1992-4 — A Critical Re-examination by Hand Calculation, Nonlinear Finite-element Analysis (Code_Aster) and the AAS Equal-Share Method

    by Yves De Lathouwer

    EN 1992-4 verifies concrete edge failure of a multi-row anchor group loaded in shear towards a free edge by assuming that only the row closest to the edge is effective and that it carries the whole shear load. The consequence is paradoxical: the verified resistance does not grow when rows are added behind the front row, it falls when a row is added in front of existing anchors, and it rises when the holes of the front row are deliberately slotted so that those anchors carry nothing. For a 3 × 3 group of M12 wedge anchors (s = 150 mm, hef = 70 mm, C25/30, h = 250 mm) at c1 = 75, 100 and 150 mm, the code gives 31, 39 and 56 kN (uncracked), while the same anchors with the front row slotted give 73, 78 and 87 kN. The paper examines this rule with three tools: the EN 1992-4 calculation, the equal-share method implemented in the AAS anchor-design software (every anchor carries the same share and the front row is verified with its share only), and a three-dimensional nonlinear finite-element analysis in Code_Aster with a regularised damage model for concrete, elastic steel shanks and a rigid fixture. The analyses show that, without hole clearance, every row is active up to failure: at peak load the front row carries practically its own stand-alone resistance while the two rows behind it carry 2.1 to 4.4 times as much, and the group resists 5.4, 3.9 and 2.9 times the load of the front row acting alone — where EN 1992-4 assumes 1.0. Removing the front row altogether does not increase the computed resistance, so adding anchors near the edge does not weaken the group, and with a hole clearance that lets the front row fail first the group still reaches 92 to 94 % of its resistance, at a larger displacement. Normalised to the characteristic level, the finite-element group resistance is about 147, 146 and 161 kN, i.e. 4.7, 3.8 and 2.9 times the EN value. The equal-share (AAS) method is close to this behaviour and conservative for c1 = 75 and 100 mm, but at c1 = 150 mm it reaches the resistance of the global break-out body that starts behind the back row, which the equal-share rule does not see. A verification rule is therefore proposed that keeps the equal share and adds that global check: the group resistance is the lesser of (n/n1) times the front-row resistance and the resistance of the back row carrying the whole load. For the cases studied it is conservative by a nearly constant factor of 1.4 to 1.6 with respect to the normalised finite-element results, against 2.9 to 4.7 for the present rule.

  • Open Access

    The Pry-out Factor: A Critical Re-examination of the Link between Tension and Pry-out Resistance in EN 1992-4

    by Yves De Lathouwer

    EN 1992-4:2018 does not verify concrete pry-out on its own terms. It sets the pry-out resistance of a fastener at a multiple k8 of its tension resistance: the concrete cone resistance for mechanical fasteners, and the smaller of the cone resistance and the combined pull-out resistance for bonded fasteners, with default values k8 = 1 or 2. This paper examines that factor. For the bond term, clause 7.2.2.4(1) names the mechanism itself: pull-out under a tension force induced by the shear. With k8 = 2 the code therefore assumes that half of the shear reaches the bond as tension. The mechanics of a laterally loaded anchor in concrete, with local crushing at the mouth of the hole, a pivot at 1.5d–2d and a tilted shank, give an induced tension of 14–27 % of the shear for plastic tilts of 8°–15°, so the factor between bond resistance and the shear it can resist is about 4 to 7. A credibility criterion shows that shear-induced pull-out can precede steel shear failure only below a bond-strength threshold that depends on hef/d alone; in 76 single-anchor configurations within the admitted embedment range the bond term governed 21 times under the code and never with a factor of 4. For the concrete term, the largest recent test database shows the code to be conservative, with mean test-to-prediction ratios of 1.27 for single anchors and 1.63 for groups, corresponding to an effective factor of about 2.5 and 3.3, and product assessments already grant k8 up to 2.9. The group rules reduce the resistance with overlap factors derived for tension, although for anchors in line with the load the rear anchor compresses the concrete in which the front anchor’s crater must form. The provisions are also inconsistent: the same Hilti HUS4 screw is checked without its pull-out resistance as a mechanical fastener and with it as a bonded screw, and the mortar is credited for embedment depth but not for diameter. A separate factor kp ≥ 4 on the bond term and a test-based recalibration of k8 for single anchors and groups are proposed, with a test programme to confirm them.

  • Open Access

    Where arethe Cracks in the Definition of "Cracked Concrete"? A Critical Review of the Normative Basis for the Cracked-Concrete Default in Post-Installed Anchor Design, and the Case for a Probabilistic Classification

    by Yves De Lathouwer

    EN 1992-4 permits a fastening to be designed for uncracked concrete only where the absence of cracking can be demonstrated over the whole anchorage depth; in the absence of that demonstration the concrete is taken as cracked. In practice the demonstration is rarely attempted, and the cracked assumption has hardened into a near-universal default. The design consequence is substantial: the characteristic concrete cone resistance in cracked concrete is approximately 70 % of the uncracked value, and for bonded fasteners the declared bond resistance in cracked concrete is commonly one half to two thirds of the uncracked value. This paper examines whether the default is proportionate to the evidence supporting it. Five observations are developed. First, both EN 1992-1-1 and EN 1992-4 define the reference crack by its width (0.3 mm) and are silent on its depth, so a shallow surface crack and a crack traversing the full section are treated identically, although their effect on an embedded fastener is not. Second, the guidance issued by the British Board of Agrément (Guidance No. 39) already frames the question probabilistically, as a joint probability involving the location of the crack, the variability of imposed load in time and space, and the independence of the fastening load from that imposed load, a framing that the Eurocode's binary classification discards. Third, a real flexural crack is wedge-shaped: it is widest at the tensile face and closes to zero at its tip, so a crack of 0.3 mm at the surface is necessarily narrower at every depth below it, whereas the qualification specimen is cracked to approximately uniform width through the member. The two geometries are mutually exclusive. Fourth, the action required to open a crack of 0.3 mm has never been related to the depths at which fasteners are installed; worked examples given here show that the reference crack corresponds to a steel stress of 300 to 350 N/mm², some 70 to 80 % of design yield, so that a slab in ordinary service carries surface cracks of 0.14 to 0.23 mm and engages, over a typical anchorage, a mean width under half the value at which the fastener was assessed. For a fastening loaded purely in shear the fastener contributes nothing to opening the crack at all, and none of the three checks that can then govern draws on any parameter obtained from testing in cracked concrete. Fifth, recent experimental work on the contribution of supplementary and surface reinforcement indicates that the cone model underlying the classification omits a resistance mechanism that is systematically present in real members. A worked example from a current European Technical Assessment shows the same pattern in the pry-out check, where the declared product-specific factor places the pry-out resistance permanently above the fastener's own steel resistance, so that the failure mode the factor quantifies cannot be produced by the product it describes. The paper also notes, as a limitation of the evidence base rather than as an allegation, that the great majority of anchor testing is funded by manufacturers whose commercial interest is served by the more onerous classification. In place of the binary default a graded framework of factors is proposed, ordered so that the condition of the member decides whether a crack of the reference kind can be present at all, the geometry of the anchorage decides how much of it the fastener would engage, and the properties of the connection modify probability and consequence without ever deciding the classification on their own. Its boundaries are stated explicitly: seismic design, and any case of genuine doubt, remain cracked.

  • Open Access

    Where Are the Cracks in the Definition of “Cracked Concrete”? A Critical Review of the Normative Basis for the Cracked-Concrete Default in Post-Installed Anchor Design, and the Case for a Probabilistic Classification

    by Yves de Lathouwer

    EN 1992-4 permits a fastening to be designed for uncracked concrete only where the absence of cracking can be demonstrated over the whole anchorage depth; in the absence of that demonstration the concrete is taken as cracked. In practice the demonstration is rarely attempted, and the cracked assumption has hardened into a near-universal default. The design consequence is substantial: the characteristic concrete cone resistance in cracked concrete is approximately 70% of the uncracked value, and for bonded fasteners the declared bond resistance in cracked concrete is commonly one half to two thirds of the uncracked value. This paper examines whether the default is proportionate to the evidence supporting it. Five observations are developed. First, both EN 1992-1-1 and EN 1992-4 define the reference crack by its width (0.3 mm) and are silent on its depth, so a shallow surface crack and a crack traversing the full section are treated identically, although their effect on an embedded fastener is not. Second, the guidance issued by the British Board of Agrément (Guidance No. 39) already frames the question probabilistically — as a joint probability involving the location of the crack, the variability of imposed load in time and space, and the independence of the fastening load from that imposed load — a framing that the Eurocode’s binary classification discards. Third, a real flexural crack is wedge-shaped: it is widest at the tensile face and closes to zero at its tip, so a crack of 0.3 mm at the surface is necessarily narrower at every depth below it, whereas the qualification specimen is cracked to approximately uniform width through the member. The two geometries are mutually exclusive. Fourth, the action required to open a crack of 0.3 mm has never been related to the depths at which fasteners are installed; worked examples given here show that the reference crack corresponds to a steel stress of 300 to 350 N/mm², some 70 to 80% of design yield, so that a slab in ordinary service carries surface cracks of 0.14 to 0.22 mm and engages, over a typical anchorage, a mean width under half the value at which the fastener was assessed. For a fastening loaded purely in shear the fastener contributes nothing to opening the crack at all, and none of the three checks that can then govern draws on any parameter obtained from testing in cracked concrete. Fifth, recent experimental work on the contribution of supplementary and surface reinforcement indicates that the cone model underlying the classification omits a resistance mechanism that is systematically present in real members. A worked example from a current European Technical Assessment shows the same pattern in the pry-out check, where the declared product-specific factor places the pry-out resistance permanently above the fastener’s own steel resistance, so that the failure mode the factor quantifies cannot be produced by the product it describes. The paper also notes, as a limitation of the evidence base rather than as an allegation, that the great majority of anchor testing is funded by manufacturers whose commercial interest is served by the more onerous classification. In place of the binary default a graded framework of factors is proposed, ordered so that the condition of the member decides whether a crack of the reference kind can be present at all, the geometry of the anchorage decides how much of it the fastener would engage, and the properties of the connection modify probability and consequence without ever deciding the classification on their own. Its boundaries are stated explicitly: seismic design, and any case of genuine doubt, remain cracked.