Shin Ae Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shin Ae Lee has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Dohern Kym
Department of Surgery and Critical Care, Burn Center, Hangang Sacred Heart Hospital, Hallym University Medical Center, Seoul, Korea
1 shared publication - Hasung Kim
Department of Burn Surgery, Hangang Sacred Heart Hospital, Hallym University College of Medicine, Seoul 07247, Republic of Korea
1 shared publication - Jaechul Yoon
Department of Surgery, Hallym University Hangang Sacred Heart Hospital, Hallym University Medical Center, Seoul, Korea
1 shared publication - Jongsoo Park
Department of Burn Surgery, Hangang Sacred Heart Hospital, Hallym University College of Medicine, Seoul 07247, Republic of Korea
1 shared publication - Jun Hur
Department of Burn Surgery, Hangang Sacred Heart Hospital, Hallym University College of Medicine, Seoul 07247, Republic of Korea
1 shared publication - Myongjin Kim
Department of Burn Surgery, Hangang Sacred Heart Hospital, Hallym University College of Medicine, Seoul 07247, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 5 September 2026
- Published by MDPI AG in Journal of Imaging
- Vol. 12 (9) , 418
Intentional Degradation for Stabilizing Residual Learning in Coarse-to-Fine Medical Image Refinement
Background: Two-stage coarse-to-fine architectures are commonly used in medical image synthesis and refinement. However, when the distributional gap between coarse inputs and high-resolution targets is large, the second-stage generator may produce unstable or weakly conditioned refinements rather than operating as a true residual corrector. Methods: We propose intentional degradation, a target-side distribution-alignment strategy that deliberately degrades high-resolution targets toward the coarse prediction space before residual learning. The degradation profile is guided by measured differences in contrast, saturation, and edge energy. We further evaluate refinement quality using two residual-space metrics: Var(Δ), the variance of the predicted residual (target minus input), and Δ-SSIM, the structural similarity between the predicted and true residual maps; both are designed to reveal refinement instability that conventional image-level metrics (e.g., SSIM computed on the full image) may not capture. We evaluated the approach in three medical imaging domains: wound-healing photography, retinal fundus imaging, and dermoscopy. Results: Across all three domains, intentional degradation consistently improved Δ-SSIM and normalized residual variance recovery relative to the baseline, and predicted residuals showed substantially stronger directional correspondence with the true residual (assessed via sign-agreement and cosine-similarity metrics) than the baseline, which converged toward directionally random predictions. These findings suggest that residual-space and direction-sensitive metrics can reveal refinement instability that may not be captured by conventional image-level metrics alone. Conclusions: Intentional degradation provides a simple, architecture-agnostic-by-design strategy for stabilizing residual learning in coarse-to-fine medical image refinement, validated within a single ConvLSTM-based refinement framework; extension to other architectures remains for future validation. Rather than introducing a new network architecture, the method modifies the target-side training distribution to reduce the mismatch between coarse inputs and high-resolution targets.
- 5 September 2026
- Published by MDPI AG in Journal of Imaging
- Vol. 12 (9) , 418
Open AccessIntentional Degradation for Stabilizing Residual Learning in Coarse-to-Fine Medical Image Refinement
Background: Two-stage coarse-to-fine architectures are commonly used in medical image synthesis and refinement. However, when the distributional gap between coarse inputs and high-resolution targets is large, the second-stage generator may produce unstable or weakly conditioned refinements rather than operating as a true residual corrector. Methods: We propose intentional degradation, a target-side distribution-alignment strategy that deliberately degrades high-resolution targets toward the coarse prediction space before residual learning. The degradation profile is guided by measured differences in contrast, saturation, and edge energy. We further evaluate refinement quality using two residual-space metrics: Var(Δ), the variance of the predicted residual (target minus input), and Δ-SSIM, the structural similarity between the predicted and true residual maps; both are designed to reveal refinement instability that conventional image-level metrics (e.g., SSIM computed on the full image) may not capture. We evaluated the approach in three medical imaging domains: wound-healing photography, retinal fundus imaging, and dermoscopy. Results: Across all three domains, intentional degradation consistently improved Δ-SSIM and normalized residual variance recovery relative to the baseline, and predicted residuals showed substantially stronger directional correspondence with the true residual (assessed via sign-agreement and cosine-similarity metrics) than the baseline, which converged toward directionally random predictions. These findings suggest that residual-space and direction-sensitive metrics can reveal refinement instability that may not be captured by conventional image-level metrics alone. Conclusions: Intentional degradation provides a simple, architecture-agnostic-by-design strategy for stabilizing residual learning in coarse-to-fine medical image refinement, validated within a single ConvLSTM-based refinement framework; extension to other architectures remains for future validation. Rather than introducing a new network architecture, the method modifies the target-side training distribution to reduce the mismatch between coarse inputs and high-resolution targets.