Libo Lan
Libo Lan has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Jiaheng Miao
College of Water Conservances and Intelligence Engineering, China Agricultural University, Beijing 100083, China
1 shared publication - Jing Xu
College of Water Resources and Civil Engineering, China Agricultural University, Beijing 100083, China
1 shared publication - Tianyang Liu
College of Water Conservances and Intelligence Engineering, China Agricultural University, Beijing 100083, China
1 shared publication - Xiugang Li
Beijing Kingpeng International Hi-Tech Corporation, Beijing 100094, China
1 shared publication - Xiugen Jiang
College of Water Conservances and Intelligence Engineering, China Agricultural University, Beijing 100083, China
1 shared publication - Zongmin Liang
College of Water Resources and Civil Engineering, China Agricultural University, Beijing 100083, China
1 shared publication
Latest Publications
- Open Access
Experimental Investigation of the Moment–Rotation Behaviour and Rotational Stiffness of Aluminium Gutter–Steel Column Connections in Multi-Span Glasshouses
Conventional structural analysis of multi-span glasshouses often idealises aluminium gutter–steel column connections as pinned or rigid, although their actual rotational restraint remains insufficiently quantified. In this study, 21 full-scale specimens were tested to investigate two representative configurations: STP joints between gutters and gable columns and STZ joints between gutters and intermediate columns. The measured secant rotational stiffness ranged from 108.5 to 185.5 kN·m/rad for STP joints and from 5.63 to 19.03 kN·m/rad for STZ joints. STP joints exhibited higher in-plane flexural resistance and rotational stiffness with smaller rotations, whereas STZ joints showed lower stiffness and greater nonlinear rotational deformation. The experimental results demonstrate that neither connection can be adequately represented as perfectly pinned or fully rigid. When the measured stiffnesses were introduced into an idealised elastic column model, the theoretical buckling capacity increased by 4.73–7.89% for STP end columns and 3.73–12.08% for STZ intermediate columns. The measured stiffnesses provide experimentally based rotational-spring parameters for refined glasshouse structural analysis.
Open AccessExperimental Investigation of the Moment–Rotation Behaviour and Rotational Stiffness of Aluminium Gutter–Steel Column Connections in Multi-Span Glasshouses
Conventional structural analysis of multi-span glasshouses often idealises aluminium gutter–steel column connections as pinned or rigid, although their actual rotational restraint remains insufficiently quantified. In this study, 21 full-scale specimens were tested to investigate two representative configurations: STP joints between gutters and gable columns and STZ joints between gutters and intermediate columns. The measured secant rotational stiffness ranged from 108.5 to 185.5 kN·m/rad for STP joints and from 5.63 to 19.03 kN·m/rad for STZ joints. STP joints exhibited higher in-plane flexural resistance and rotational stiffness with smaller rotations, whereas STZ joints showed lower stiffness and greater nonlinear rotational deformation. The experimental results demonstrate that neither connection can be adequately represented as perfectly pinned or fully rigid. When the measured stiffnesses were introduced into an idealised elastic column model, the theoretical buckling capacity increased by 4.73–7.89% for STP end columns and 3.73–12.08% for STZ intermediate columns. The measured stiffnesses provide experimentally based rotational-spring parameters for refined glasshouse structural analysis.