Kevin Kitir
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kevin Kitir has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Clara Egner
University of Vienna / Vienna Doctoral School of Pharmaceutical
3 shared publications - Hans Kainz
University of Vienna
3 shared publications - Laura Rathmair
University of Vienna
3 shared publications - Willi Koller
University of Vienna
3 shared publications - Tim Max Emmenegger
Medical University of Vienna
1 shared publication - Wolfgang Bogner
Medical University of Vienna
1 shared publication
Latest Publications
- Open Access
- 20 October 2026
- Published by University of Bern in Current Issues in Sport Science (CISS)
- Vol. 11 (5) , 012
Automated MRI-based assessment of paediatric femoral geometry: establishing objective reference values for femoral neck–shaft and anteversion angles
Introduction & Purpose Femoral neck–shaft angle (NSA) and femoral anteversion angle (AVA) influence lower-limb alignment, joint loading, and movement biomechanics during growth (Figure 1a). Altered femoral geometry has been associated with changes in gait mechanics and musculoskeletal overload, highlighting its relevance for clinical biomechanics, sports medicine, and paediatric movement research (Kainz et al., 2023). Although femoral morphology has been widely investigated (Szuper et al., 2015; Staheli et al., 1985; Bobroff et al., 1999), large-scale assessment remains challenging due to time-consuming manual measurements, operator dependency, and methodological variability (Boese et al., 2016; Kaiser et al., 2016). This study aimed to develop an automated MRI-based workflow combining deep learning femur segmentation with deterministic geometric analysis to quantify NSA and AVA and generate reference distributions in typically developing children. Methods Whole-limb MRI scans of 52 typically developing children, 24 female and 28 male, without known lower-limb pathologies or pain, aged 5–16 years, were analysed. In total, 104 femora were available. Femora for which automated geometric fitting did not yield plausible angle estimates were excluded. Femoral segmentation was performed using a self-trained 3D nnU- Net model (Isensee et al., 2021) trained on 37 manually annotated femur segmentations (Figure 1b). The resulting masks were processed using the deterministic MSKsInertiaGeom pipeline, combining STAPLE-based processing of segmented bone geometries, following Modenese and Renault (2021), with inertia-axis calculations and refined geometric fitting to derive NSA and AVA without manual landmark placement. Linear mixed-effects models accounted for bilateral femoral measurements, with participant identity as a random effect and age, sex, and age-by-sex interaction as fixed effects. Significance was defined as p < 0.05. Results Automated geometric fitting succeeded in 102 of 104 femora. Mean NSA was 132.9 ± 5.8° with a range of 120° to 145°, while mean AVA was 22.4 ± 10.0° with a range of 0° to 45°. Linear mixed-effects modelling demonstrated a significant negative association between age and NSA, with β = −0.94°/year and p < 0.001. AVA showed no statistically significant association with age, with β = −0.70°/year and p = 0.109. No statistically significant sex-related differences were observed for NSA or AVA, and no significant age-by-sex interactions were detected. The resulting distributions provide reference values across the investigated age range (Figure 1c). Discussion This automated MRI-based framework enables scalable, operator-independent quantification of paediatric femoral morphology. The observed age-related decrease in NSA is consistent with reported developmental patterns of proximal femoral morphology (Hefti, 2007), whereas AVA demonstrated substantial inter-individual variability and no significant age dependency. Limitations include the single-centre and cross-sectional design, lack of formal validation against independent manual segmentation and measurement protocols and failed geometric fitting in two femora. Conclusion An automated MRI-based pipeline integrating deep learning segmentation and deterministic geometric analysis enables objective quantification of paediatric femoral NSA and AVA. These reference values may support future biomechanical and sports science research investigating femoral morphology in movement development, physical activity, sports participation, and musculoskeletal overload during growth. References 1. Kainz, H., Mindler, G. T., & Kranzl, A. (2023). Influence of femoral anteversion angle and neck-shaft angle on muscle forces and joint loading during walking. PLOS ONE, 18(10), e0291458. https://doi.org/10.1371/journal.pone.0291458 2. Szuper, K., Schlégl, Á. T., Leidecker, E., Vermes, C., Sándor, B., & Than, P. (2015). Three- dimensional quantitative analysis of the proximal femur and the pelvis in children and adolescents using an upright biplanar slot-scanning X-ray system. Pediatric Radiology, 45, 411–421. https://doi.org/10.1007/s00247-014-3146-2 3. Staheli, L. T., Corbett, M., Wyss, C., & King, H. (1985). Lower-extremity rotational problems in children. The Journal of Bone and Joint Surgery. American Volume, 67(1), 39–47. https://doi.org/10.2106/00004623-198567010-00006 4. Bobroff, E. D., Chambers, H. G., Sartoris, D. J., Wyatt, M. P., & Sutherland, D. H. (1999). Femoral anteversion and neck-shaft angle in children with cerebral palsy. Clinical Orthopaedics and Related Research, 364, 194–204. https://doi.org/10.1097/00003086- 199907000-00025 5. Boese, C. K., Dargel, J., Oppermann, J., Eysel, P., Scheyerer, M. J., Bredow, J., & Lechler, P. (2016). The femoral neck-shaft angle on plain radiographs: A systematic review. Skeletal Radiology, 45, 19–28. https://doi.org/10.1007/s00256-015-2236-z 6. Kaiser, P., Attal, R., Kammerer, M., et al. (2016). Significant differences in femoral torsion values depending on the CT measurement technique. Archives of Orthopaedic and Trauma Surgery, 136, 1259–1264. https://doi.org/10.1007/s00402-016-2536-3 7. Isensee, F., Jaeger, P. F., Kohl, S. A. A., Petersen, J., & Maier-Hein, K. H. (2021). nnU- Net: A self-configuring method for deep learning-based biomedical image segmentation. Nature Methods, 18, 203–211. https://doi.org/10.1038/s41592-020-01008-z 8. Modenese, L., & Renault, J.-B. (2021). Automatic generation of personalised skeletal models of the lower limb from three-dimensional bone geometries. Journal of Biomechanics, 116, 110186. https://doi.org/10.1016/j.jbiomech.2020.110186 9. Hefti, F. (2007). Pediatric Orthopedics in Practice. Springer. https://doi.org/10.1007/978-3- 540-69964-4
- 20 October 2026
- Published by University of Bern in Current Issues in Sport Science (CISS)
- Vol. 11 (5) , 012
Open AccessAutomated MRI-based assessment of paediatric femoral geometry: establishing objective reference values for femoral neck–shaft and anteversion angles
Introduction & Purpose Femoral neck–shaft angle (NSA) and femoral anteversion angle (AVA) influence lower-limb alignment, joint loading, and movement biomechanics during growth (Figure 1a). Altered femoral geometry has been associated with changes in gait mechanics and musculoskeletal overload, highlighting its relevance for clinical biomechanics, sports medicine, and paediatric movement research (Kainz et al., 2023). Although femoral morphology has been widely investigated (Szuper et al., 2015; Staheli et al., 1985; Bobroff et al., 1999), large-scale assessment remains challenging due to time-consuming manual measurements, operator dependency, and methodological variability (Boese et al., 2016; Kaiser et al., 2016). This study aimed to develop an automated MRI-based workflow combining deep learning femur segmentation with deterministic geometric analysis to quantify NSA and AVA and generate reference distributions in typically developing children. Methods Whole-limb MRI scans of 52 typically developing children, 24 female and 28 male, without known lower-limb pathologies or pain, aged 5–16 years, were analysed. In total, 104 femora were available. Femora for which automated geometric fitting did not yield plausible angle estimates were excluded. Femoral segmentation was performed using a self-trained 3D nnU- Net model (Isensee et al., 2021) trained on 37 manually annotated femur segmentations (Figure 1b). The resulting masks were processed using the deterministic MSKsInertiaGeom pipeline, combining STAPLE-based processing of segmented bone geometries, following Modenese and Renault (2021), with inertia-axis calculations and refined geometric fitting to derive NSA and AVA without manual landmark placement. Linear mixed-effects models accounted for bilateral femoral measurements, with participant identity as a random effect and age, sex, and age-by-sex interaction as fixed effects. Significance was defined as p < 0.05. Results Automated geometric fitting succeeded in 102 of 104 femora. Mean NSA was 132.9 ± 5.8° with a range of 120° to 145°, while mean AVA was 22.4 ± 10.0° with a range of 0° to 45°. Linear mixed-effects modelling demonstrated a significant negative association between age and NSA, with β = −0.94°/year and p < 0.001. AVA showed no statistically significant association with age, with β = −0.70°/year and p = 0.109. No statistically significant sex-related differences were observed for NSA or AVA, and no significant age-by-sex interactions were detected. The resulting distributions provide reference values across the investigated age range (Figure 1c). Discussion This automated MRI-based framework enables scalable, operator-independent quantification of paediatric femoral morphology. The observed age-related decrease in NSA is consistent with reported developmental patterns of proximal femoral morphology (Hefti, 2007), whereas AVA demonstrated substantial inter-individual variability and no significant age dependency. Limitations include the single-centre and cross-sectional design, lack of formal validation against independent manual segmentation and measurement protocols and failed geometric fitting in two femora. Conclusion An automated MRI-based pipeline integrating deep learning segmentation and deterministic geometric analysis enables objective quantification of paediatric femoral NSA and AVA. These reference values may support future biomechanical and sports science research investigating femoral morphology in movement development, physical activity, sports participation, and musculoskeletal overload during growth. References 1. Kainz, H., Mindler, G. T., & Kranzl, A. (2023). Influence of femoral anteversion angle and neck-shaft angle on muscle forces and joint loading during walking. PLOS ONE, 18(10), e0291458. https://doi.org/10.1371/journal.pone.0291458 2. Szuper, K., Schlégl, Á. T., Leidecker, E., Vermes, C., Sándor, B., & Than, P. (2015). Three- dimensional quantitative analysis of the proximal femur and the pelvis in children and adolescents using an upright biplanar slot-scanning X-ray system. Pediatric Radiology, 45, 411–421. https://doi.org/10.1007/s00247-014-3146-2 3. Staheli, L. T., Corbett, M., Wyss, C., & King, H. (1985). Lower-extremity rotational problems in children. The Journal of Bone and Joint Surgery. American Volume, 67(1), 39–47. https://doi.org/10.2106/00004623-198567010-00006 4. Bobroff, E. D., Chambers, H. G., Sartoris, D. J., Wyatt, M. P., & Sutherland, D. H. (1999). Femoral anteversion and neck-shaft angle in children with cerebral palsy. Clinical Orthopaedics and Related Research, 364, 194–204. https://doi.org/10.1097/00003086- 199907000-00025 5. Boese, C. K., Dargel, J., Oppermann, J., Eysel, P., Scheyerer, M. J., Bredow, J., & Lechler, P. (2016). The femoral neck-shaft angle on plain radiographs: A systematic review. Skeletal Radiology, 45, 19–28. https://doi.org/10.1007/s00256-015-2236-z 6. Kaiser, P., Attal, R., Kammerer, M., et al. (2016). Significant differences in femoral torsion values depending on the CT measurement technique. Archives of Orthopaedic and Trauma Surgery, 136, 1259–1264. https://doi.org/10.1007/s00402-016-2536-3 7. Isensee, F., Jaeger, P. F., Kohl, S. A. A., Petersen, J., & Maier-Hein, K. H. (2021). nnU- Net: A self-configuring method for deep learning-based biomedical image segmentation. Nature Methods, 18, 203–211. https://doi.org/10.1038/s41592-020-01008-z 8. Modenese, L., & Renault, J.-B. (2021). Automatic generation of personalised skeletal models of the lower limb from three-dimensional bone geometries. Journal of Biomechanics, 116, 110186. https://doi.org/10.1016/j.jbiomech.2020.110186 9. Hefti, F. (2007). Pediatric Orthopedics in Practice. Springer. https://doi.org/10.1007/978-3- 540-69964-4
- Open Access
- 20 October 2026
- Published by University of Bern in Current Issues in Sport Science (CISS)
- Vol. 11 (5) , 011
Alterations in Hip and Knee Joint Contact Force Waveforms and Orientation Induced by Gait Modifications: A Case Study
Introduction & Purpose Idiopathic torsional deformities of lower limb bones can affect a patient’s gait pattern and joint health, while their cause remains unidentified (Koller et al., 2026). Abnormal joint loadings and the progression of degenerative diseases such as osteoarthritis in adults can be altered through gait modifications (Diamond et al., 2022, Uhlrich et al., 2022). Bone growth is regulated by mechanical stimuli (Carter & Wong, 1988; Frost, 2001), and normalizing joint loadings might be a non-invasive treatment option (Kainz et al., 2020; Koller et al., 2024). What constitutes normal versus abnormal joint contact forces (JCF) remains unidentified and most likely varies by individual. Koller et al. (2026) reported the effect of hip joint loads on proximal femoral growth plate stresses during different foot progression angles (FPA). This study aimed to evaluate several established gait modifications’ abilities to steer hip (HJCF) and knee JCF (KJCF) magnitude and orientation using a personalized musculoskeletal model. Methods One healthy child (15y, m) underwent MRI and three-dimensional gait analysis (Vicon, Oxford, UK) on an instrumented treadmill (AMTI, Watertown, USA), including electromyography of 16 lower limb muscles. After familiarization, he walked at preferred speed, and with altered FPA (in-/out-toeing), stance widths, speeds, and foot-strike patterns. A personalized musculoskeletal model was created using OpenSim Creator’s Model Warper (Kewley et al., 2026) within the MRI2MSKworkflow (Koller, 2026), adapting an OpenSim model (Rajagopal et al., 2016; Uhlrich et al., 2022, Lerner et al., 2015) to the individual’s anatomy obtained from imaging. JCFs per leg and condition were calculated using OpenSim (Delp et al., 2007) and the Muscle Redundancy Solver (De Groote et al., 2016). All trials were post-hoc classified into gait modification categories, as their implementation varied for each step. Results All gait modification results were compared to those of preferred walking style. Out-toeing increased the first peak of HJCF, patellofemoral (PFJCF) and KJCF, but decreased the second peak of HJCF and KJCF. A wider stance lowered, while narrow stance increased HJCF during terminal stance. KJCF had a slightly lower second peak for wide stance variations. Walking with exaggerated plantarflexion (push-off) lowered PFJCF during mid-stance and increased and slightly advanced the second peak of KJCF. Fast walking increased PFJCF during loading response, while slow walking decreased it. Figure 1B shows that all gait deviations except forefoot and slow walking shifted HJCF orientation anteriorly, while these two shifted it posteriorly. Discussion Measuring subject-specific joint loading and identifying abnormal loading patterns supports movement diagnostics across all populations to detect potential risks early. This study demonstrated that coachable gait cues alter joint loads and may influence bone development. Kinematic and kinetic results agreed with Schwartz et al.(2008) for slow, preferred and fast walking. Further studies incorporating finite element simulations are needed to determine the effect of these deviations on femoral growth. Conclusion Recent studies emphasize the need for model personalization and individualized assessment. We showed that gait modifications induce measurable changes in hip and knee joint loading. The effect of gait alterations on longitudinal bone growth remains to be determined. References Carter, D.R. & Wong, M. (1988), The role of mechanical loading histories in the development of diarthrodial joints. J. Orthop. Res., 6: 804-816. https://doi.org/10.1002/jor.1100060604 De Groote, F., Kinney, A.L., Rao, A.V. & Fregly, B.J. (2016). Evaluation of Direct Collocation Optimal Control Problem Formulations for Solving the Muscle Redundancy Problem. Ann Biomedl Eng, 44. https://doi.org/10.1007/s10439-016-1591-9 Delp, S. L., Anderson, F. C., Arnold, A. S., Loan, P., Habib, A., John, C. T., Guendelman, E., Thelen, D. G. (2007). OpenSim: Open-source Software to Create and Analyze Dynamic Simulations of Movement. IEEE Transactions on Biomedical Engineering. (2007). https://doi.org/10.1109/TBME.2007.901024 Diamond, L. E., Devaprakash, D., Cornish, B., Plinsinga, M. L., Hams, A., Hall, M., et al. (2022). Feasibility of personalised hip load modification using real-time biofeedback in hip osteoarthritis: a pilot study. Osteoarthr. Cartil. Open 4, Article 100230. https://doi.org/10.1016/j.ocarto.2021.100230 Frost, H.M. (2001), From Wolff's law to the Utah paradigm: Insights about bone physiology and its clinical applications. Anat. Rec., 262: 398-419. https://doi.org/10.1002/ar.1049 Jiang L., Iwamoto, Y., Ezumi, S., Ishii, Y., Kita, S., Takahashi, M. (2025). Effect of wider step-width gait on hip joint contact force. Journal of Biomechanics 186, 112742. https://doi. org/10.1016/j.jbiomech.2025.112742 Kainz, H., Killen, B. A., Wesseling, M., Perez-Boerema, F., Pitto, L., Garcia Aznar, J. M., et al. (2020). A multi-scale modelling framework combining musculoskeletal rigid-body simulations with adaptive finite element analyses, to evaluate the impact of femoral geometry on hip joint contact forces and femoral bone growth. PLoS ONE 15, Article 7: e0235966. https://doi.org/10.1371/journal.pone.0235966 Kewley, A., van Beesel, J., & Seth, A. (2026). OpenSim creator: an interactive user interface for building OpenSim musculoskeletal models. J. Open Source Softw. 11, Article 8284. https://doi.org/10.21105/joss.08284 Koller, W., Wallnöfer, E., Holder, J., Kranzl, A., Mindler, G., Baca, A., et al. (2024). ESMAC best paper award 2023: increased knee flexion in participants with cerebral palsy results in altered stresses at the distal femoral growth plate compared to a typically developing cohort. Gait Posture 113, 158–166. https://doi.org/10.1016/j.gaitpost.2024.06.012 Koller, W. (2026). MRI2MSK. GitHub repository,...
- 20 October 2026
- Published by University of Bern in Current Issues in Sport Science (CISS)
- Vol. 11 (5) , 011
Open AccessAlterations in Hip and Knee Joint Contact Force Waveforms and Orientation Induced by Gait Modifications: A Case Study
Introduction & Purpose Idiopathic torsional deformities of lower limb bones can affect a patient’s gait pattern and joint health, while their cause remains unidentified (Koller et al., 2026). Abnormal joint loadings and the progression of degenerative diseases such as osteoarthritis in adults can be altered through gait modifications (Diamond et al., 2022, Uhlrich et al., 2022). Bone growth is regulated by mechanical stimuli (Carter & Wong, 1988; Frost, 2001), and normalizing joint loadings might be a non-invasive treatment option (Kainz et al., 2020; Koller et al., 2024). What constitutes normal versus abnormal joint contact forces (JCF) remains unidentified and most likely varies by individual. Koller et al. (2026) reported the effect of hip joint loads on proximal femoral growth plate stresses during different foot progression angles (FPA). This study aimed to evaluate several established gait modifications’ abilities to steer hip (HJCF) and knee JCF (KJCF) magnitude and orientation using a personalized musculoskeletal model. Methods One healthy child (15y, m) underwent MRI and three-dimensional gait analysis (Vicon, Oxford, UK) on an instrumented treadmill (AMTI, Watertown, USA), including electromyography of 16 lower limb muscles. After familiarization, he walked at preferred speed, and with altered FPA (in-/out-toeing), stance widths, speeds, and foot-strike patterns. A personalized musculoskeletal model was created using OpenSim Creator’s Model Warper (Kewley et al., 2026) within the MRI2MSKworkflow (Koller, 2026), adapting an OpenSim model (Rajagopal et al., 2016; Uhlrich et al., 2022, Lerner et al., 2015) to the individual’s anatomy obtained from imaging. JCFs per leg and condition were calculated using OpenSim (Delp et al., 2007) and the Muscle Redundancy Solver (De Groote et al., 2016). All trials were post-hoc classified into gait modification categories, as their implementation varied for each step. Results All gait modification results were compared to those of preferred walking style. Out-toeing increased the first peak of HJCF, patellofemoral (PFJCF) and KJCF, but decreased the second peak of HJCF and KJCF. A wider stance lowered, while narrow stance increased HJCF during terminal stance. KJCF had a slightly lower second peak for wide stance variations. Walking with exaggerated plantarflexion (push-off) lowered PFJCF during mid-stance and increased and slightly advanced the second peak of KJCF. Fast walking increased PFJCF during loading response, while slow walking decreased it. Figure 1B shows that all gait deviations except forefoot and slow walking shifted HJCF orientation anteriorly, while these two shifted it posteriorly. Discussion Measuring subject-specific joint loading and identifying abnormal loading patterns supports movement diagnostics across all populations to detect potential risks early. This study demonstrated that coachable gait cues alter joint loads and may influence bone development. Kinematic and kinetic results agreed with Schwartz et al.(2008) for slow, preferred and fast walking. Further studies incorporating finite element simulations are needed to determine the effect of these deviations on femoral growth. Conclusion Recent studies emphasize the need for model personalization and individualized assessment. We showed that gait modifications induce measurable changes in hip and knee joint loading. The effect of gait alterations on longitudinal bone growth remains to be determined. References Carter, D.R. & Wong, M. (1988), The role of mechanical loading histories in the development of diarthrodial joints. J. Orthop. Res., 6: 804-816. https://doi.org/10.1002/jor.1100060604 De Groote, F., Kinney, A.L., Rao, A.V. & Fregly, B.J. (2016). Evaluation of Direct Collocation Optimal Control Problem Formulations for Solving the Muscle Redundancy Problem. Ann Biomedl Eng, 44. https://doi.org/10.1007/s10439-016-1591-9 Delp, S. L., Anderson, F. C., Arnold, A. S., Loan, P., Habib, A., John, C. T., Guendelman, E., Thelen, D. G. (2007). OpenSim: Open-source Software to Create and Analyze Dynamic Simulations of Movement. IEEE Transactions on Biomedical Engineering. (2007). https://doi.org/10.1109/TBME.2007.901024 Diamond, L. E., Devaprakash, D., Cornish, B., Plinsinga, M. L., Hams, A., Hall, M., et al. (2022). Feasibility of personalised hip load modification using real-time biofeedback in hip osteoarthritis: a pilot study. Osteoarthr. Cartil. Open 4, Article 100230. https://doi.org/10.1016/j.ocarto.2021.100230 Frost, H.M. (2001), From Wolff's law to the Utah paradigm: Insights about bone physiology and its clinical applications. Anat. Rec., 262: 398-419. https://doi.org/10.1002/ar.1049 Jiang L., Iwamoto, Y., Ezumi, S., Ishii, Y., Kita, S., Takahashi, M. (2025). Effect of wider step-width gait on hip joint contact force. Journal of Biomechanics 186, 112742. https://doi. org/10.1016/j.jbiomech.2025.112742 Kainz, H., Killen, B. A., Wesseling, M., Perez-Boerema, F., Pitto, L., Garcia Aznar, J. M., et al. (2020). A multi-scale modelling framework combining musculoskeletal rigid-body simulations with adaptive finite element analyses, to evaluate the impact of femoral geometry on hip joint contact forces and femoral bone growth. PLoS ONE 15, Article 7: e0235966. https://doi.org/10.1371/journal.pone.0235966 Kewley, A., van Beesel, J., & Seth, A. (2026). OpenSim creator: an interactive user interface for building OpenSim musculoskeletal models. J. Open Source Softw. 11, Article 8284. https://doi.org/10.21105/joss.08284 Koller, W., Wallnöfer, E., Holder, J., Kranzl, A., Mindler, G., Baca, A., et al. (2024). ESMAC best paper award 2023: increased knee flexion in participants with cerebral palsy results in altered stresses at the distal femoral growth plate compared to a typically developing cohort. Gait Posture 113, 158–166. https://doi.org/10.1016/j.gaitpost.2024.06.012 Koller, W. (2026). MRI2MSK. GitHub repository,...
- Open Access
- 3 September 2026
- Published by University of Bern in Current Issues in Sport Science (CISS)
- Vol. 11 (5) , 047
Musculoskeletal Models from Sparse Medical Images – Towards Personalized Load Management in Sports and Medicine
Introduction & Purpose Internal musculoskeletal loads (e.g. muscle-forces, joint-moments, and joint-contact-forces) are key indicators of locomotor loading, relevant to sports medicine and rehabilitation. Since many such variables cannot be measured directly, they are estimated using musculoskeletal modelling, driven by 3D-gait-analysis (3DGA) (marker trajectories, electromyography, ground reaction forces). Personalization of musculoskeletal models ranges from simple scaling of a generic model to fully personalized medical-image-based models; more personalization is assumed to improve accuracy but increases time/resources (Kainz & Jonkers, 2023; Modenese et al., 2021; Stansfield et al., 2025). We present a semi-automatic workflow that personalizes models from sparse images typically collected in clinical settings and evaluate muscle-lengths against a scaled-generic model and a full-image-based model during gait. Methods 3DGA and magnetic-resonance-imaging (MRI) data were collected for one individual (female, age: 16years, mass: 52.1kg, height: 172cm) with ethics approval and parental consent. Gait condition: overground-walking, barefoot, self-selected speed. Bones (pelvis, femur, tibia/fibula) were segmented from MRI using 3Dslicer. To imitate sparse clinical images, we retained proximal/distal 15% of femur/tibia/fibula and distal 45% of pelvis. A Statistical Shape Model (SSM) (Carman et al., 2022) was fit to the sparse segmentations using a genetic algorithm in MATLAB (Conn et al., 1991, 1997; Goldberg, 1989) to reconstruct full bones automatically. Three OpenSim models were generated based on the RajagopalLaiUhlrich-model (Rajagopal et al., 2016; Uhlrich et al., 2022): (1) Generic-scaled: using OpenSim’s Scaling Tool (Delp et al., 2007) (automated); (2) Full-personalized: via OpenSim Creator’s Model Warper (Kewley et al., 2026) using full segmentations, as previously described by Koller et al., 2026 (semi-automatic involving manual landmark setting); (3) Sparse-personalized: same warping pipeline applied to SSM-reconstructed bones (Figure 1). Inverse Kinematics and Muscle Analysis yielded joint-angles and muscle-tendon-lengths. Similarity was assessed qualitatively and by root mean squared difference (RMSD) over the gait cycle. Results Waveforms of muscle-tendon-lengths showed similar patterns for all models (Figure 1). Sparse-model was more similar in magnitudes (lower RMSD) to the Full-model than the Generic-model for 85% of muscles. Exceptions were found predominantly in adductors and hip flexors, for which the Generic was closer to the Full than the Sparse-model (Figure 1), likely reflecting pelvis reconstruction challenges when proximal anatomy is missing. Maximum RMSD was 2.5cm for Full-vs.-Sparse-comparison (iliacus), and 5.3cm for Full-vs.-Generic-comparison (tensor fasciae latae). Discussion Our sparse-image-based personalization approximated full-image models for most muscle-tendon-length waveforms using routine-like MRI subsets. Remaining errors highlight the need for stronger pelvis constraints/proximal landmarks. Relative to prior work, we: (i) reconstruct subject-specific bones from sparse MRI via SSM; (ii) integrate this with a semi-automatic OpenSim warping pipeline; and (iii) benchmark against generic and fully image-based models. Upon validation on larger datasets, reconstructing full bone geometry from sparse clinical images enables retrospective modelling in cohorts lacking research-grade scans. As an N=1 pilot, findings are preliminary. Conclusion Sparse-image-based personalization primarily advances retrospective musculoskeletal modeling from routine clinical imaging, broadening applicability across sites and age groups. Further work will validate in a larger, diverse cohort and extend outcomes (joint-kinematics, joint-contact-forces, muscle-forces), with targeted improvements to pelvis/hip reconstruction. References Carman, L., Besier, T. F., & Choisne, J. (2022). Morphological variation in paediatric lower limb bones. Scientific Reports, 12(1), 3251. https://doi.org/10.1038/s41598-022-07267-4 Conn, A. R., Gould, N. I. M., & Toint, P. (1991). A Globally Convergent Augmented Lagrangian Algorithm for Optimization with General Constraints and Simple Bounds. SIAM Journal on Numerical Analysis, 28(2), 545–572. https://doi.org/10.1137/0728030 Conn, A. R., Gould, N., & Toint, Ph. L. (1997). A globally convergent Lagrangian barrier algorithm for optimization with general inequality constraints and simple bounds. Mathematics of Computation, 66(217), 261–289. https://doi.org/10.1090/S0025-5718-97-00777-1 Delp, S. L., Anderson, F. C., Arnold, A. S., Loan, P., Habib, A., John, C. T., Guendelman, E., & Thelen, D. G. (2007). OpenSim: Open-Source Software to Create and Analyze Dynamic Simulations of Movement. IEEE Transactions on Biomedical Engineering, 54(11), 1940–1950. https://doi.org/10.1109/TBME.2007.901024 Goldberg, D. E. (1989). Genetic Algorithms in Search, Optimization & Machine Learning. Addison-Wesley. Kainz, H., & Jonkers, I. (2023). Imaging-based musculoskeletal models alter muscle and joint contact forces but do not improve the agreement with experimentally measured electromyography signals in children with cerebral palsy. Gait & Posture, 100, 91–95. https://doi.org/10.1016/j.gaitpost.2022.11.019 Kewley, A., Van Beesel, J., & Seth, A. (2026). OpenSim Creator: An Interactive User Interface for Building OpenSim Musculoskeletal Models. Journal of Open Source Software, 11(117), 8284. https://doi.org/10.21105/joss.08284 Koller, W., Wallnöfer, E., Rathmair, L., Egner, C., Kitir, K., & Kainz, H. (2026). Foot progression angle modifications alter hip joint contact forces and femoral growth plate mechanics in children. Frontiers in Bioengineering and Biotechnology, 14, 1799347. https://doi.org/10.3389/fbioe.2026.1799347 Modenese, L., Barzan, M., & Carty, C. P. (2021). Dependency of lower limb joint reaction forces on femoral...
- 3 September 2026
- Published by University of Bern in Current Issues in Sport Science (CISS)
- Vol. 11 (5) , 047
Open AccessMusculoskeletal Models from Sparse Medical Images – Towards Personalized Load Management in Sports and Medicine
Introduction & Purpose Internal musculoskeletal loads (e.g. muscle-forces, joint-moments, and joint-contact-forces) are key indicators of locomotor loading, relevant to sports medicine and rehabilitation. Since many such variables cannot be measured directly, they are estimated using musculoskeletal modelling, driven by 3D-gait-analysis (3DGA) (marker trajectories, electromyography, ground reaction forces). Personalization of musculoskeletal models ranges from simple scaling of a generic model to fully personalized medical-image-based models; more personalization is assumed to improve accuracy but increases time/resources (Kainz & Jonkers, 2023; Modenese et al., 2021; Stansfield et al., 2025). We present a semi-automatic workflow that personalizes models from sparse images typically collected in clinical settings and evaluate muscle-lengths against a scaled-generic model and a full-image-based model during gait. Methods 3DGA and magnetic-resonance-imaging (MRI) data were collected for one individual (female, age: 16years, mass: 52.1kg, height: 172cm) with ethics approval and parental consent. Gait condition: overground-walking, barefoot, self-selected speed. Bones (pelvis, femur, tibia/fibula) were segmented from MRI using 3Dslicer. To imitate sparse clinical images, we retained proximal/distal 15% of femur/tibia/fibula and distal 45% of pelvis. A Statistical Shape Model (SSM) (Carman et al., 2022) was fit to the sparse segmentations using a genetic algorithm in MATLAB (Conn et al., 1991, 1997; Goldberg, 1989) to reconstruct full bones automatically. Three OpenSim models were generated based on the RajagopalLaiUhlrich-model (Rajagopal et al., 2016; Uhlrich et al., 2022): (1) Generic-scaled: using OpenSim’s Scaling Tool (Delp et al., 2007) (automated); (2) Full-personalized: via OpenSim Creator’s Model Warper (Kewley et al., 2026) using full segmentations, as previously described by Koller et al., 2026 (semi-automatic involving manual landmark setting); (3) Sparse-personalized: same warping pipeline applied to SSM-reconstructed bones (Figure 1). Inverse Kinematics and Muscle Analysis yielded joint-angles and muscle-tendon-lengths. Similarity was assessed qualitatively and by root mean squared difference (RMSD) over the gait cycle. Results Waveforms of muscle-tendon-lengths showed similar patterns for all models (Figure 1). Sparse-model was more similar in magnitudes (lower RMSD) to the Full-model than the Generic-model for 85% of muscles. Exceptions were found predominantly in adductors and hip flexors, for which the Generic was closer to the Full than the Sparse-model (Figure 1), likely reflecting pelvis reconstruction challenges when proximal anatomy is missing. Maximum RMSD was 2.5cm for Full-vs.-Sparse-comparison (iliacus), and 5.3cm for Full-vs.-Generic-comparison (tensor fasciae latae). Discussion Our sparse-image-based personalization approximated full-image models for most muscle-tendon-length waveforms using routine-like MRI subsets. Remaining errors highlight the need for stronger pelvis constraints/proximal landmarks. Relative to prior work, we: (i) reconstruct subject-specific bones from sparse MRI via SSM; (ii) integrate this with a semi-automatic OpenSim warping pipeline; and (iii) benchmark against generic and fully image-based models. Upon validation on larger datasets, reconstructing full bone geometry from sparse clinical images enables retrospective modelling in cohorts lacking research-grade scans. As an N=1 pilot, findings are preliminary. Conclusion Sparse-image-based personalization primarily advances retrospective musculoskeletal modeling from routine clinical imaging, broadening applicability across sites and age groups. Further work will validate in a larger, diverse cohort and extend outcomes (joint-kinematics, joint-contact-forces, muscle-forces), with targeted improvements to pelvis/hip reconstruction. References Carman, L., Besier, T. F., & Choisne, J. (2022). Morphological variation in paediatric lower limb bones. Scientific Reports, 12(1), 3251. https://doi.org/10.1038/s41598-022-07267-4 Conn, A. R., Gould, N. I. M., & Toint, P. (1991). A Globally Convergent Augmented Lagrangian Algorithm for Optimization with General Constraints and Simple Bounds. SIAM Journal on Numerical Analysis, 28(2), 545–572. https://doi.org/10.1137/0728030 Conn, A. R., Gould, N., & Toint, Ph. L. (1997). A globally convergent Lagrangian barrier algorithm for optimization with general inequality constraints and simple bounds. Mathematics of Computation, 66(217), 261–289. https://doi.org/10.1090/S0025-5718-97-00777-1 Delp, S. L., Anderson, F. C., Arnold, A. S., Loan, P., Habib, A., John, C. T., Guendelman, E., & Thelen, D. G. (2007). OpenSim: Open-Source Software to Create and Analyze Dynamic Simulations of Movement. IEEE Transactions on Biomedical Engineering, 54(11), 1940–1950. https://doi.org/10.1109/TBME.2007.901024 Goldberg, D. E. (1989). Genetic Algorithms in Search, Optimization & Machine Learning. Addison-Wesley. Kainz, H., & Jonkers, I. (2023). Imaging-based musculoskeletal models alter muscle and joint contact forces but do not improve the agreement with experimentally measured electromyography signals in children with cerebral palsy. Gait & Posture, 100, 91–95. https://doi.org/10.1016/j.gaitpost.2022.11.019 Kewley, A., Van Beesel, J., & Seth, A. (2026). OpenSim Creator: An Interactive User Interface for Building OpenSim Musculoskeletal Models. Journal of Open Source Software, 11(117), 8284. https://doi.org/10.21105/joss.08284 Koller, W., Wallnöfer, E., Rathmair, L., Egner, C., Kitir, K., & Kainz, H. (2026). Foot progression angle modifications alter hip joint contact forces and femoral growth plate mechanics in children. Frontiers in Bioengineering and Biotechnology, 14, 1799347. https://doi.org/10.3389/fbioe.2026.1799347 Modenese, L., Barzan, M., & Carty, C. P. (2021). Dependency of lower limb joint reaction forces on femoral...