Shijie Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Shijie Yang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Chenyang Xue
Laoshan Laboratory, Qingdao 266237, China
1 shared publication - Libo Gao
Pen-Tung Sah Institute of Micro-Nano Science and Technology, Xiamen University, Xiamen, 361102, China
1 shared publication - Rushan Xie
Laoshan Laboratory, Qingdao 266237, China
1 shared publication - Zhonggang Zhang
Marine Engineering Institute, Jimei University, Xiamen 361021, China
1 shared publication - Ziming Ren
Laoshan Laboratory, Qingdao 266237, China
1 shared publication
Latest Publications
- Open Access
- 6 September 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (9) , 1061
Design and Implementation of a Quartz Cilia MEMS Vector Hydrophone
The cilium avoids energy loss due to bending deformation during vibration, thereby efficiently transmitting the acoustic driving force to the cross-beam. Meanwhile, a hollow cylindrical structure is adopted instead of the traditional solid one. While maintaining the same external geometry, this hollow design not only increases the effective acoustic area to enhance the acoustic driving force but also reduces the added mass of the cilium. This material–structure synergistic optimization improves the acoustic-to-mechanical transfer efficiency of the cilium in low-frequency acoustic fields, thus enhancing the device’s acoustic sensitivity in the low-frequency range. Parametric simulations are conducted using the COMSOL Multiphysics 6.3 platform to systematically optimize key geometric parameters such as the outer radius and height of the quartz cilium, and the optimal dimensions are determined. The sensitivity and directivity of the prototype are measured in the 20–1000 Hz frequency range using the standard hydrophone comparison method. Experimental results show that the quartz cilium vector hydrophone achieves a sensitivity of –179.1 dB (1 kHz, 0 dB = 1 V/μPa) at 1000 Hz. The frequency response curve exhibits good flatness in the low-frequency range and agrees well with the theoretical 6 dB per octave increase characteristic of pressure gradient sensors. Directivity tests reveal a typical figure-8 pattern at both 315 Hz and 630 Hz, with null depths exceeding 30 dB, demonstrating excellent vector detection capability. This study provides an effective approach for improving the low-frequency sensitivity of MEMS (Micro-Electromechanical System) vector hydrophones, and the designed device meets the requirements for underwater target detection with promising prospects for engineering applications.
- 6 September 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (9) , 1061
Open AccessDesign and Implementation of a Quartz Cilia MEMS Vector Hydrophone
The cilium avoids energy loss due to bending deformation during vibration, thereby efficiently transmitting the acoustic driving force to the cross-beam. Meanwhile, a hollow cylindrical structure is adopted instead of the traditional solid one. While maintaining the same external geometry, this hollow design not only increases the effective acoustic area to enhance the acoustic driving force but also reduces the added mass of the cilium. This material–structure synergistic optimization improves the acoustic-to-mechanical transfer efficiency of the cilium in low-frequency acoustic fields, thus enhancing the device’s acoustic sensitivity in the low-frequency range. Parametric simulations are conducted using the COMSOL Multiphysics 6.3 platform to systematically optimize key geometric parameters such as the outer radius and height of the quartz cilium, and the optimal dimensions are determined. The sensitivity and directivity of the prototype are measured in the 20–1000 Hz frequency range using the standard hydrophone comparison method. Experimental results show that the quartz cilium vector hydrophone achieves a sensitivity of –179.1 dB (1 kHz, 0 dB = 1 V/μPa) at 1000 Hz. The frequency response curve exhibits good flatness in the low-frequency range and agrees well with the theoretical 6 dB per octave increase characteristic of pressure gradient sensors. Directivity tests reveal a typical figure-8 pattern at both 315 Hz and 630 Hz, with null depths exceeding 30 dB, demonstrating excellent vector detection capability. This study provides an effective approach for improving the low-frequency sensitivity of MEMS (Micro-Electromechanical System) vector hydrophones, and the designed device meets the requirements for underwater target detection with promising prospects for engineering applications.