HHHao Huang

Hao Huang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hao Huang has a total of 98 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Characterization of a Resistively Multiplexed SiPM Readout for Position-Sensitive Scintillating Fibre Radiation Detectors

    by Klemen Žagar, Gregor Košir, Matjaž Vencelj, Eva Lovšin, Tobe Mulder, Jürgen Gerl, Hao Huang, Guang-Shun Li, Jelena Vesić

    Active stoppers based on scintillating fibres provide fast signal formation, fine segmentation and compact geometry. On the other hand, their implementation requires a readout that can handle many silicon photomultiplier channels and a wide range of light intensities. We present a laboratory characterization of a resistively multiplexed SiPM readout for the Fibre IMPlanter concept. The readout combines 16 SiPM input nodes into four analog outputs. Localized pulsed light excitation was used to scan individual SiPM positions, and the four signals were processed by baseline subtraction, charge integration and normalized charge division reconstruction. In an intermediate signal range, the reconstructed position plane shows distinguishable clusters for the individual inputs, indicating that spatial information is retained after a factor-of-four reduction in readout channels. At low amplitudes, the reconstruction is limited by baseline noise and reduced signal-to-noise ratio. At high amplitudes, the energy proxy signal response is affected by SiPM non-linearity and finite microcell occupancy, while position reconstruction accuracy is limited by distortions of the charge sharing. The results identify the signal range in which resistive multiplexing remains a practical compact readout option for SiPM-based scintillating fibre radiation detectors.

  • Open Access

    Identification of a nanosecond isomer of $^{164}$Tb

    by J. P. Bormans, J. E. L. Larsson, H. M. Albers, M. Górska, M. Polettini, D. Brugnara, N. Pietralla, Zs. Podolyák, P. H. Regan, B. Bles, et al.

    This letter reports on the identification of a new isomeric state of $$^{164}$$ 164 Tb ( $$Z=65$$ Z = 65 , $$N=99$$ N = 99 ), which was measured with the DESPEC setup at the GSI Helmholtzzentrum für Schwerionenforschung GmbH following the first relativistic fragmentation of an $$^{170}$$ 170 Er primary beam. From the time distribution and coincidences of the emitted $$\gamma $$ γ rays, the isomer is tentatively assigned to a state with spin-parity $$(7^{-})$$ ( 7 - ) at an excitation energy of $$283.3(2)~\textrm{keV}$$ 283.3 ( 2 ) keV with a half-life of $$159(11)~\textrm{ns}$$ 159 ( 11 ) ns . The isomer is interpreted as the $$\pi 7/2^{-}[523]\otimes \nu 7/2^{+}[633]$$ π 7 / 2 - [ 523 ] ⊗ ν 7 / 2 + [ 633 ] configuration from the Nilsson orbital systematics. These results represent the first report of $$\gamma $$ γ -ray spectroscopy of $$^{164}$$ 164 Tb, providing insight into the ground-state and low-lying level structure.

  • Open Access

    Characterization of a Resistively Multiplexed SiPM Readout for Position-Sensitive Scintillating-Fibre Radiation Detectors

    by K. Žagar, G. Košir, M. Vencelj, E. Lovšin, T. Mulder, J. Gerl, H. Hao, G. S. Li, J. Vesić

    Active stoppers based on scintillating fibres provide fast signal formation, fine segmentation and compact geometry. On the other hand, their implementation requires a readout that can handle many silicon photomultiplier channels and a wide range of light intensities. We present a laboratory characterization of a resistively multiplexed SiPM readout for the Fibre IMPlanter concept. The readout combines 16 SiPM input nodes into four analog outputs. Localized pulsed-light excitation was used to scan individual SiPM positions, and the four signals were processed by baseline subtraction, charge integration and normalized charge-division reconstruction. In an intermediate signal range, the reconstructed position plane shows distinguishable clusters for the individual inputs, indicating that spatial information is retained after a factor-of-four reduction in readout channels. At low amplitudes, the reconstruction is limited by baseline noise and reduced signal-to-noise ratio. At high amplitudes, it is limited by SiPM non-linearity, finite microcell occupancy and distortions of the charge sharing. The results identify the signal range in which resistive multiplexing remains a practical compact readout option for SiPM-based scintillating-fibre radiation detectors.