Yun Chen
Research Subjects
Yun Chen has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Baojun Hui
China Southern Power Grid Electric Power Research Institute, Guangzhou 510663, China
1 shared publication - Bin Feng
CSG Electric Power Research Institute Co., Ltd., Guangzhou 510663, China
1 shared publication - Jie Liu
CSG Electric Power Research Institute Co., Ltd., Guangzhou 510663, China
1 shared publication - Mao Li
Guangzhou Power Supply Bureau, Guangdong Power Grid Co., Ltd., Guangzhou 510620, China
1 shared publication - Qichao Chen
State Key Laboratory of High-Efficiency Special Cable Technology, Harbin University of Science and Technology, Harbin 150080, China
1 shared publication - Shuai Hou
CSG Electric Power Research Institute Co., Ltd
1 shared publication
Latest Publications
- Open Access
- 12 September 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (18) , 9061
Acoustic-Vibration Attenuation Characteristics of Polymeric Insulating Materials and Distributed Feedback Fiber Laser-Based Partial Discharge Detection in Cables
Partial discharge (PD) generates transient acoustic-vibration signals that can be used for the passive monitoring of cable insulation. Unlike previous studies that separately addressed DFB-FL sensitivity, polymer-property effects, or acoustic attenuation in a particular cable, this study establishes an application-oriented cross-scale assessment that links material-level propagation loss with cable-scale detection by a distributed feedback fiber laser (DFB-FL)/fiber Bragg grating (FBG) system. This study compared the Young’s moduli of polypropylene (PP), cross-linked polyethylene (XLPE), and methyl silicone rubber (MQ), and measured their frequency-dependent attenuation coefficients along with those of insulating oil in the range of 50 to 300 kHz. Subsequently, a 250 mm-long, 220 kV XLPE cable specimen containing a needle-induced artificial cavity was tested at sensing distances of 0–7 cm and at four circumferential positions. For the three tested materials, the extrapolated initial response amplitude decreased as the Young’s modulus increased. The measured polymer attenuation coefficients were approximately 0.052–0.192 Np/cm, compared with approximately 0.018–0.033 Np/cm for insulating oil. Under the stated laboratory criteria, the lowest time-correlated apparent-charge event detected by the DFB-FL system was 16 pC. The DFB-FL peak-to-peak response decreased from 5.04 Vpp at 0 cm to 1.00 Vpp at 7 cm, crossing below the background threshold between 6 and 7 cm, which experimentally verifies the intrinsic connection among material attenuation, internal cable propagation paths, and sensor-placement constraints.
- 12 September 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (18) , 9061
Open AccessAcoustic-Vibration Attenuation Characteristics of Polymeric Insulating Materials and Distributed Feedback Fiber Laser-Based Partial Discharge Detection in Cables
Partial discharge (PD) generates transient acoustic-vibration signals that can be used for the passive monitoring of cable insulation. Unlike previous studies that separately addressed DFB-FL sensitivity, polymer-property effects, or acoustic attenuation in a particular cable, this study establishes an application-oriented cross-scale assessment that links material-level propagation loss with cable-scale detection by a distributed feedback fiber laser (DFB-FL)/fiber Bragg grating (FBG) system. This study compared the Young’s moduli of polypropylene (PP), cross-linked polyethylene (XLPE), and methyl silicone rubber (MQ), and measured their frequency-dependent attenuation coefficients along with those of insulating oil in the range of 50 to 300 kHz. Subsequently, a 250 mm-long, 220 kV XLPE cable specimen containing a needle-induced artificial cavity was tested at sensing distances of 0–7 cm and at four circumferential positions. For the three tested materials, the extrapolated initial response amplitude decreased as the Young’s modulus increased. The measured polymer attenuation coefficients were approximately 0.052–0.192 Np/cm, compared with approximately 0.018–0.033 Np/cm for insulating oil. Under the stated laboratory criteria, the lowest time-correlated apparent-charge event detected by the DFB-FL system was 16 pC. The DFB-FL peak-to-peak response decreased from 5.04 Vpp at 0 cm to 1.00 Vpp at 7 cm, crossing below the background threshold between 6 and 7 cm, which experimentally verifies the intrinsic connection among material attenuation, internal cable propagation paths, and sensor-placement constraints.