Xi Chen
Xi Chen has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Weixiang Huang
Electric Power Research Institute of Guangxi Power Grid Co., Ltd., Guangxi Power Grid Equipment Monitoring and Diagnosis Engineering Technology Research Center, Nanning 530023, China
2 shared publications - Bo Feng
Guangxi Key Laboratory of Intelligent Control and Operation and Maintenance of Power Equipment, Electric Power Research Institute of Guangxi Power Grid Co., Ltd., Nanning 530023, China
1 shared publication - Chenying Yi
Electric Power Research Institute of Guangxi Power Grid Co., Ltd., Guangxi Power Grid Equipment Monitoring and Diagnosis Engineering Technology Research Center, Nanning 530023, China
1 shared publication - Shan Li
Guangxi Power Grid Equipment Monitoring and Diagnosis Engineering Technology Research Center, Electric Power Research Institute of Guangxi Power Grid Co., Ltd., Nanning 530023, China
1 shared publication - Wei Zhang
Guangxi Power Grid Equipment Monitoring and Diagnosis Engineering Technology Research Center, Electric Power Research Institute of Guangxi Power Grid Co., Ltd., Nanning 530023, China
1 shared publication - Weijun Hu
Fangchenggang Power Bureau of Guangxi Power Grid Co., Ltd., Fangchenggang 538000, China
1 shared publication
Latest Publications
- Open Access
Lightning Risk Assessment and Improvement of 110 kV Double-Circuit Transmission Lines on Shared Towers
A single lightning strike on a double-circuit transmission line with shared towers may affect both circuits, while lightning risk varies among towers along the line. This study examines a 110 kV line in Guangxi, China, using lightning monitoring and operational records. Multi-wave-impedance models of representative tower types were developed in ATP-EMTP, and lightning withstand levels were determined using an insulator voltage–time characteristic criterion implemented in MODELS. An electrogeometric model was then used to estimate tower-level shielding-failure and backflashover trip-out rates, classify lightning risk, and propose a line surge arrester configuration. Thirty-three towers were identified for priority protection. In a model-based preliminary assessment, the estimated lightning-induced trip-out rate decreased from 9.747 to 2.579 trips per 100 km per year, a reduction of 73.54%. This case study provides a reference for differentiated lightning protection of similar lines.
Open AccessLightning Risk Assessment and Improvement of 110 kV Double-Circuit Transmission Lines on Shared Towers
A single lightning strike on a double-circuit transmission line with shared towers may affect both circuits, while lightning risk varies among towers along the line. This study examines a 110 kV line in Guangxi, China, using lightning monitoring and operational records. Multi-wave-impedance models of representative tower types were developed in ATP-EMTP, and lightning withstand levels were determined using an insulator voltage–time characteristic criterion implemented in MODELS. An electrogeometric model was then used to estimate tower-level shielding-failure and backflashover trip-out rates, classify lightning risk, and propose a line surge arrester configuration. Thirty-three towers were identified for priority protection. In a model-based preliminary assessment, the estimated lightning-induced trip-out rate decreased from 9.747 to 2.579 trips per 100 km per year, a reduction of 73.54%. This case study provides a reference for differentiated lightning protection of similar lines.
- Open Access
- 14 September 2026
- Published by MDPI AG in Atmosphere
- Vol. 17 (9) , 894
A Downscaling Method for Cloud-to-Ground Stroke Density and Its Improvement on Tower-Level Lightning Hazard Risk Identification
Cloud-to-ground (CG) stroke density is key for lightning hazard risk assessment, but conventional grid-cell methods face an inherent trade-off between spatial resolution and statistical confidence. To address this issue, this study takes Fangchenggang City, Guangxi, as the study area and proposes an extreme gradient boosting (XGBoost) regression model integrating high-resolution terrain features to estimate CG stroke density at the hundred-meter scale. The results show that the model produces a 0.001° × 0.001° density distribution that reproduces the spatial pattern of lightning activity. Within the ±30% error interval, the average confidence level of the model output is approximately 44.75%, while that of the grid-cell method is only 0.0163%. The two-dimensional information entropy reaches 10.70 bits, approximately 33.9% higher than that of the grid-cell method. SHAP analysis indicates that the XGBoost model successfully performed smooth interpolation on the raw data to obtain a high-resolution density map showing the effects of topographical factors. Furthermore, a case study of a lightning-induced trip-out event on a 220 kV transmission line illustrates the method’s potential applicability. Compared with kilometer-scale density data, the high-resolution data yield an identified faulty tower that is more consistent with the actual accident location. In summary, we have proposed an effective downscaling method for Cloud-to-Ground stroke density. It is worth noting, however, that independent validation remains limited and that the confidence calculation does not incorporate model uncertainty.
- 14 September 2026
- Published by MDPI AG in Atmosphere
- Vol. 17 (9) , 894
Open AccessA Downscaling Method for Cloud-to-Ground Stroke Density and Its Improvement on Tower-Level Lightning Hazard Risk Identification
Cloud-to-ground (CG) stroke density is key for lightning hazard risk assessment, but conventional grid-cell methods face an inherent trade-off between spatial resolution and statistical confidence. To address this issue, this study takes Fangchenggang City, Guangxi, as the study area and proposes an extreme gradient boosting (XGBoost) regression model integrating high-resolution terrain features to estimate CG stroke density at the hundred-meter scale. The results show that the model produces a 0.001° × 0.001° density distribution that reproduces the spatial pattern of lightning activity. Within the ±30% error interval, the average confidence level of the model output is approximately 44.75%, while that of the grid-cell method is only 0.0163%. The two-dimensional information entropy reaches 10.70 bits, approximately 33.9% higher than that of the grid-cell method. SHAP analysis indicates that the XGBoost model successfully performed smooth interpolation on the raw data to obtain a high-resolution density map showing the effects of topographical factors. Furthermore, a case study of a lightning-induced trip-out event on a 220 kV transmission line illustrates the method’s potential applicability. Compared with kilometer-scale density data, the high-resolution data yield an identified faulty tower that is more consistent with the actual accident location. In summary, we have proposed an effective downscaling method for Cloud-to-Ground stroke density. It is worth noting, however, that independent validation remains limited and that the confidence calculation does not incorporate model uncertainty.