ETEduard G. Tuns

Eduard G. Tuns

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Eduard G. Tuns has a total of 2 co-authors. Here are the top co-authors by number of shared publications:

  • Mircea Nasui

    Centre for Superconductivity, Spintronics and Surface Science, Physics and Chemistry Department, Technical University of Cluj-Napoca, Str. Memorandumului No. 28, 400028 Cluj-Napoca, Romania

    2 shared publications
  • Răzvan Păcurar

    Department of Manufacturing Engineering, Faculty of Industrial Engineering, Robotics and Production Management, Technical University of Cluj-Napoca, Blv. Muncii, No. 103-105, 400641 Cluj-Napoca, Romania

    2 shared publications

Latest Publications

  • Open Access

    Masked Stereolithography of a Metacarpal Fixation Plate Prototype with a Low-Temperature Barium Titanate Coating

    by Eduard G. Tuns, Razvan Pǎcurar, Mircea Nǎsui

    Fifth metacarpal shaft fractures account for a large share of hand trauma and often require operative internal fixation, yet conventional dorsal plates and cannulated screws present a stiffness mismatch with native bone and the insertion of screws can shear surface coatings. This study presents the design, fabrication, and preliminary characterisation of a low-profile, BaTiO3-coated dorsal fixation plate prototype for the fifth metacarpal bone. A curved, 0.5 mm plate was modelled in SolidWorks and overlaid with a randomised Delaunay lattice in Meshmixer, achieving 73.6% porosity with a 70% mesh reduction strategy. A linear static finite element study of a simplified periodic surrogate of the plate (nominal polymer properties, 300 N load) is reported only as an illustrative response, not as evidence of mechanical suitability. Plates were manufactured by masked stereolithography in a water-washable resin not intended for implantation (not MED610), with an average accuracy of 98.77% on three features measured before coating; the dimensions after the 120 °C and 180 °C coating steps were not remeasured. A barium titanate precursor was synthesised via the propionate route and deposited through a three-cycle, low-temperature (120 °C) submersion process followed by a solvothermal treatment at 180 °C for 1 h. Optical microscopy and SEM/EDS showed qualitative surface coverage with barium and titanium and open pores, and XRD showed reflections consistent with perovskite BaTiO3; the polymorph, thickness, adhesion, uniformity and mechanical stability of the coating were not quantified. Under cyclic compressive loading (1–2 N), a coated plate dried at 120 °C, before the solvothermal step was introduced, generated an alternating open-circuit voltage of 0.62 ± 0.08 V at 1 N and 0.93 ± 0.10 V at 2 N (peak-to-peak), much larger than that of an uncoated plate; its origin remains to be established. This is a fabrication and preliminary characterisation study of a non-biocompatible prototype: mechanical testing of the printed structure, poled and replicate electrical measurements, and biological evaluation have not yet been performed and are the next steps.

  • Open Access

    A 4D Smart Metacarpal Implant with a Barium Titanate Piezoelectric Coating Manufactured via Masked Stereolithography

    by E.G. Tuns, R. Pǎcurar, M. Nǎsui

    Fifth metacarpal shaft fractures account for a large share of hand trauma and often re-quire operative internal fixation, yet conventional dorsal plates and cannulated screws present a stiffness mismatch with native bone and mechanically preclude active, piezo-electric coatings. This study presents the design, fabrication, and functional characteri-sation of a low-profile, 4D piezoelectric dorsal plate for the fifth metacarpal bone. A curved, 0.5 mm plate was modelled in SolidWorks and overlaid with a randomised De-launay lattice in Meshmixer, achieving 73.6% porosity and quasi-isotropic yield behav-iour via a 70% mesh-reduction strategy. Finite element analysis under a 300 N load, using MED610 biocompatible resin properties, confirmed structural integrity with a 4.083 mm peak deflection and no localised buckling. Implants were manufactured by masked stereolithography (Anycubic Photon Mono, 20 μm layers), achieving 98.75% average dimensional accuracy. A barium titanate precursor was synthesised via the propionate route and deposited through a three-cycle, low-temperature submersion process. FTIR confirmed molecular bonding between cations and the polymer matrix, while micros-copy verified a continuous, pore-preserving coating. Under cyclic compressive loading (1–2 N), the implant generated an alternating open-circuit voltage of 0.3–0.7 V. These results demonstrate an accessible stereolithography route to active, self-stimulating or-thopaedic hardware.