ASAryaman Srivastav

Aryaman Srivastav

*This is an algorithmically generated author record based on publicly available information.

Aryaman Srivastav has a total of 3 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Natural Circulation in the Gallium Thermal-hydraulic Experiment: Effect of multiple cooling loops

    by Broderick Michael Sieh, Stefano Vitello, Aryaman Srivastav, Hitesh Bindra

    The continued development of liquid metal-cooled fast reactor (LMFR) systems remains a significant goal for the advanced reactor community. A central concern for these systems is the capability of the primary coolant to circulate naturally in the event of a coolant pump failure or station blackout. Confidence in that capability rests on experimental data of sufficient spatial and thermal resolution to support verification and validation of predictive models, and the available liquid metal (LM) database remains sparse relative to its water counterpart. To address this gap, the Gallium Thermal-hydraulic Experiment (GaTE) has been reconfigured as a closed buoyancy-driven loop. GaTE employs molten gallium as a surrogate for other low-Prandtl number coolants such as liquid sodium, permitting laboratory-scale operation and comprehensive instrumentation while preserving the governing heat transfer and flow physics. Two features of the facility make these natural circulation experiments unique: two parallel cooling circuits supported by two heat exchangers and a scaled plenum above the heater. The facility has been enhanced through the installation of additional sensors for data collection during natural circulation experiments, including thermocouples and flow meters on the secondary coolant side as well as a distributed temperature sensor secured in a U-tube within the plenum; together these apparatuses allow GaTE to be operated under conditions analogous to an LMFR primary loop. Experiments were conducted with both cooling loops in service (symmetric) and with one cooling circuit isolated (asymmetric) to understand the difference. Steady-state loop mass flow rates, hot- and cold-leg temperatures, system thermal power, and distributed plenum temperature fields are reported across a range of heater powers and coolant flow rates resulting in hot-to-cold-leg temperature differences of 40, 75, 100, and 130°C. While changes in the plenum temperature field are not perceived, limit cycle oscillations are observed when two loops are in service for the tests with temperature differences across the heater of 40 and 75°C. Additionally, chaotic flow behavior is observed for tests with higher temperature differences. For tests with asymmetric cooling, no periodic oscillations are perceived and stable natural circulation is observed.