Paul Elias Panizo-Olivos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Paul Elias Panizo-Olivos has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Adlin López-Díaz
Universidad de La Frontera
1 shared publication - Cecilia Querebalu Garcia
Facultad de Ciencias Físicas
1 shared publication - Eduardo Garnique-Millones
Nuclear Medicine Center, Hospital de Alta Complejidad Virgen de la Puerta , EsSALUD, M. Bastidas 309, La Esperanza 13013, Trujillo
1 shared publication - Jhonny Antonio Benavente Castillo
Postgraduate Unit in Medical Physics, Faculty of Sciences, Universidad Nacional de Ingeniería (UNI) , Av. Túpac Amaru 210, Rímac, Lima
1 shared publication Jorge Lázaro Delgado-Morales
Department of Mathematics-Physics, Agrarian University of Havana , Carretera Tapaste y Autopista Nacional km 23 1/2, San José de las Lajas, Mayabeque
1 shared publication
Latest Publications
- 4 June 2026
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 202 (15) , 1180-1191
Establishing typical diagnostic reference levels in a Peruvian nuclear medicine centre: a retrospective study
Diagnostic reference levels (DRLs) are tools for optimizing medical exposures. We performed a retrospective analysis of 898 adult scintigraphic examinations acquired between 2018 and 2024 at a Peruvian hospital to establish institutional DRLs for eight procedures. Typical values were defined as the median administered activity, and the 75th percentiles were used as institutional action levels to trigger protocol review. Median weight-normalized activities ranged from 0.1 MBq·kg−1 for 131I thyroid uptake testing to 14.5 MBq·kg−1 for three-phase bone scintigraphy; corresponding derived effective dose estimates were ~1–45 mSv and are reported only for population-level benchmarking. Comparison with international DRLs showed broad concordance; however, bone scintigraphy exceeded several reference values by >25%, indicating opportunities for optimization. These results provide the first institutional DRLs reported in Peru, identify priorities for local quality improvement, and support periodic review within an optimization cycle.
- 4 June 2026
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 202 (15) , 1180-1191
Establishing typical diagnostic reference levels in a Peruvian nuclear medicine centre: a retrospective study
Diagnostic reference levels (DRLs) are tools for optimizing medical exposures. We performed a retrospective analysis of 898 adult scintigraphic examinations acquired between 2018 and 2024 at a Peruvian hospital to establish institutional DRLs for eight procedures. Typical values were defined as the median administered activity, and the 75th percentiles were used as institutional action levels to trigger protocol review. Median weight-normalized activities ranged from 0.1 MBq·kg−1 for 131I thyroid uptake testing to 14.5 MBq·kg−1 for three-phase bone scintigraphy; corresponding derived effective dose estimates were ~1–45 mSv and are reported only for population-level benchmarking. Comparison with international DRLs showed broad concordance; however, bone scintigraphy exceeded several reference values by >25%, indicating opportunities for optimization. These results provide the first institutional DRLs reported in Peru, identify priorities for local quality improvement, and support periodic review within an optimization cycle.