LXLuiyue Xiong

Luiyue Xiong

*This is an algorithmically generated author record based on publicly available information.

Luiyue Xiong has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Thermodynamic-exergy Analysis and Adaptive Load Control of a Recuperated Micro Gas Turbine Generator for Turboelectric Propulsion

    by Richard Amankwa Adjei, Luiyue Xiong, Tai Zhu, Yong Ren

    Recuperated micro gas turbine generators are attractive for turboelectric propulsion because they retain liquid-fuel energy density, but steady-state fuel savings do not necessarily preserve transient shaft-speed margin. This paper proposes an uncertainty-informed adaptive model predictive control (MPC) strategy for transient load management, built on a reduced-order thermodynamic, exergy and shaft-dynamic model benchmarked against a matched GasTurb turboshaft case. The controller uses scheduled load preview and online updates of turbine-lag and shaft-power-balance parameters to compensate component-map uncertainty. The benchmark gives close agreement in fuel flow (2.4%) and main state variables, while the generator-power difference falls to 3.7% when shaft-friction loss is treated consistently. For the baseline case (ϵ = 0.8), the model predicts 44.24 kW shaft power before friction, 37.48 kW electrical output and 23.19% fuel-to-electric efficiency. Exergy analysis identifies combustion and exhaust rejection as the dominant losses, with 50.89 kW destruction and 39.58 kW physical exergy loss. The recuperator tradeoff shows that higher effectiveness reduces fuel flow, but pressure losses erode electrical output, motivating joint recuperator and control assessment. Under the proportional governor, shaft-speed droop increases from 354 to 708 rpm across 10-20 kW load steps. For the 30-50 kW case, fixed MPC reduces droop from 708.37 to 18.92 rpm using exact preview, while adaptive MPC gives 16.77 rpm. Under dynamic and map perturbations, adaptive MPC reduces mean droop by 32.8% relative to fixed MPC and by 33.0% in a robustness case. Preview gives the main nominal benefit; adaptation preserves performance under uncertainty.

  • Open Access

    Battery-assisted Transient Operability and Electrical-buffer Sizing for a Recuperated Micro Gas Turbine Turbogenerator under Inlet Distortion

    by Richard Amankwa Adjei, Luiyue Xiong, Moses M. Solomon, Anthony Kwasi Martey

    Recuperated micro gas turbine turbogenerators couple relatively slow thermal power conversion to rapidly varying electrical loads, creating a transient mismatch between generator demand and turbine response. Simultaneous inlet distortion reduces compressor operability reserve and can move the operating point toward a degraded surge boundary. This study determines the electrical-buffer power and energy authority required to maintain a prescribed reserve during combined inlet-distortion and propulsive-load transients. A map-aware reduced-order model couples a recuperated thermodynamic cycle, single-shaft dynamics, prescribed total-pressure distortion, distortion-dependent compressor limits, generator loading, and a battery-connected DC bus. Proportional governing and rule-based battery assistance are compared with predictive battery control, joint turbine-battery model predictive control (MPC), and adaptive joint control. For a 30-50 kW transient with 5% total-pressure distortion, proportional governing yields a predicted minimum distorted map margin of 1.06% and remains below the declared 2.35% reserve for 3.10 s. Rule-based assistance reduces shaft-speed droop from 947 to 377 rpm but remains below the reserve for 2.70 s. Predictive battery control and joint MPC limit peak generator demand to 46.7 kW, reduce droop to approximately 236 rpm, and retain about 2.40% predicted minimum margin in the nominal simulation. The successful 20 kW-rated buffer case uses approximately 19 kW peak discharge and 151 kJ energy. The severe transient is therefore primarily power-constrained rather than energy-constrained under the tested conditions. Operability envelopes show that required buffer authority rises with load severity, distortion magnitude, and disturbance duration, while distortion-response uncertainty and preview accuracy become increasingly influential near the declared reserve. These results provide a controloriented basis for buffer sizing without claiming certification-level validation of compressor stability.