Daor Hayu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Daor Hayu has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Alon Schwartz
Department of Neurosurgery, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel
1 shared publication - Amit Wolfovitz
Department of Otolaryngology, Sheba Medical Center, Ramat Gan
1 shared publication - Dana Niry
Department of Radiology, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel
1 shared publication - David L. Horn
Department of Otolaryngology-Head and Neck Surgery, Virginia Merrill Bloedel Hearing Research Center, University of Washington, Box 357923, Seattle, Washington 98195, USA
1 shared publication - David Saltz
SUNY Downstate Health Sciences University, College of Medicine, Brooklyn, New York
1 shared publication Gladys Sanda
Welbeck, 1 Welbeck Street, London, United Kingdom
1 shared publication
Latest Publications
- 6 October 2026
- Published by Springer Nature in Neuroradiology
- p. 1-12
ABC/2 versus computer-assisted volumetric analysis for epidural hematoma: measurement variability, and the influence of hematoma morphology; a retrospective, multicenter, cohort study
Objective Accurate estimation of epidural hematoma (EDH) volume is critical for clinical decision-making, as current traumatic brain injury guidelines recommend surgical evacuation for EDH volumes exceeding 30 cm³. The manual ABC/2 method is widely used for rapid estimation, but its accuracy for EDH remains incompletely defined. This study evaluated the accuracy of ABC/2 compared with computer-assisted volumetric analysis (CAVA) in a large, multicenter cohort. Methods A retrospective analysis was performed on adult patients with traumatic EDH treated at two tertiary neurosurgical centers between 2017 and 2025. Hematoma volumes were calculated using the ABC/2 method and compared with CAVA using brainlab® or 3D-Slicer software. Correlation and agreement were assessed using Pearson correlation, paired testing, and Bland-Altman analysis, while inter-rater and intra-software reliability were assessed using intraclass correlation coefficients (ICC). Results A total of 191 patients were included (mean age 40.0 ± 15.9 years). Bland-Altman analysis showed systematic overestimation by ABC/2 (mean bias − 13.45 mL) with wide limits of agreement. Log-transformed analysis confirmed substantial proportional variability (geometric mean ratio 0.72, 95% LoA 0.15–3.44), despite a strong overall correlation (r = 0.897, p < 0.001). Overestimation was greater in classic than irregular hematomas (16 vs. 8 mL), and classification discordance occurred in 56 patients (29.3%), including 28 (14.7%) crossing the 30-mL threshold. Conclusions Although the ABC/2 method provides a rapid, practical estimate of EDH volume, it systematically overestimates hematoma size compared with CAVA and shows substantial shape- and patient-level variability. The two methods are not interchangeable, and volumes near commonly referenced operative thresholds should be interpreted cautiously. As CAVA tools become increasingly accessible, future studies should evaluate how CAVA-based measurements correlate with clinical presentation, treatment decisions, and patient outcomes, and determine how historical volume thresholds translate to modern volumetric techniques.
- 6 October 2026
- Published by Springer Nature in Neuroradiology
- p. 1-12
ABC/2 versus computer-assisted volumetric analysis for epidural hematoma: measurement variability, and the influence of hematoma morphology; a retrospective, multicenter, cohort study
Objective Accurate estimation of epidural hematoma (EDH) volume is critical for clinical decision-making, as current traumatic brain injury guidelines recommend surgical evacuation for EDH volumes exceeding 30 cm³. The manual ABC/2 method is widely used for rapid estimation, but its accuracy for EDH remains incompletely defined. This study evaluated the accuracy of ABC/2 compared with computer-assisted volumetric analysis (CAVA) in a large, multicenter cohort. Methods A retrospective analysis was performed on adult patients with traumatic EDH treated at two tertiary neurosurgical centers between 2017 and 2025. Hematoma volumes were calculated using the ABC/2 method and compared with CAVA using brainlab® or 3D-Slicer software. Correlation and agreement were assessed using Pearson correlation, paired testing, and Bland-Altman analysis, while inter-rater and intra-software reliability were assessed using intraclass correlation coefficients (ICC). Results A total of 191 patients were included (mean age 40.0 ± 15.9 years). Bland-Altman analysis showed systematic overestimation by ABC/2 (mean bias − 13.45 mL) with wide limits of agreement. Log-transformed analysis confirmed substantial proportional variability (geometric mean ratio 0.72, 95% LoA 0.15–3.44), despite a strong overall correlation (r = 0.897, p < 0.001). Overestimation was greater in classic than irregular hematomas (16 vs. 8 mL), and classification discordance occurred in 56 patients (29.3%), including 28 (14.7%) crossing the 30-mL threshold. Conclusions Although the ABC/2 method provides a rapid, practical estimate of EDH volume, it systematically overestimates hematoma size compared with CAVA and shows substantial shape- and patient-level variability. The two methods are not interchangeable, and volumes near commonly referenced operative thresholds should be interpreted cautiously. As CAVA tools become increasingly accessible, future studies should evaluate how CAVA-based measurements correlate with clinical presentation, treatment decisions, and patient outcomes, and determine how historical volume thresholds translate to modern volumetric techniques.
- 20 July 2026
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 47 (9) , 1196-1204
Quality of Tinnitus Information From Generative AI Systems and Web Search: An Expert‑Rated Comparative Study
Objective: To compare the quality of tinnitus-related information generated by multiple generative artificial intelligence (GenAI) systems and web search using expert evaluation. Study design: Cross-sectional comparative study. Setting: Digital platforms evaluated in their native public interfaces. Patients: Not applicable. Thirty commonly searched tinnitus-related questions derived from United States Google Trends data (2020–2025). Intervention(s): Questions were submitted to 6 GenAI systems (OpenEvidence, Claude, DeepSeek, GPT-5, Gemini, GPT-4) and Google Search (first organic result). Responses were independently rated by 6 experts using the QAMAI framework. Main outcome measure(s): Mean expert-rated quality scores across 5 domains (accuracy, clarity, relevance, completeness, and usefulness). Results: Overall quality differed significantly across systems (Friedman P r =0.49–0.86). Inter-rater reliability was high (ICC=0.82). Readability demonstrated an inverse pattern relative to expert-rated quality. OpenEvidence demonstrated the lowest readability (Flesch-Kincaid Grade Level 17.5; Flesch Reading Ease 2.2), corresponding to a postgraduate reading level, whereas general-purpose LLMs produced more accessible responses at a sixth–seventh grade reading level. Conclusions: The quality of tinnitus information varies substantially across digital platforms. While GenAI systems generally outperform web search, deficiencies in completeness persist. Readability analysis revealed an inverse relationship between expert-rated quality and response accessibility, suggesting that clinician and patient assessments of informational value may not always align. These findings highlight the need for continued evaluation and clinician oversight to ensure safe, comprehensive, and accessible patient-facing information.
- 20 July 2026
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 47 (9) , 1196-1204
Quality of Tinnitus Information From Generative AI Systems and Web Search: An Expert‑Rated Comparative Study
Objective: To compare the quality of tinnitus-related information generated by multiple generative artificial intelligence (GenAI) systems and web search using expert evaluation. Study design: Cross-sectional comparative study. Setting: Digital platforms evaluated in their native public interfaces. Patients: Not applicable. Thirty commonly searched tinnitus-related questions derived from United States Google Trends data (2020–2025). Intervention(s): Questions were submitted to 6 GenAI systems (OpenEvidence, Claude, DeepSeek, GPT-5, Gemini, GPT-4) and Google Search (first organic result). Responses were independently rated by 6 experts using the QAMAI framework. Main outcome measure(s): Mean expert-rated quality scores across 5 domains (accuracy, clarity, relevance, completeness, and usefulness). Results: Overall quality differed significantly across systems (Friedman P r =0.49–0.86). Inter-rater reliability was high (ICC=0.82). Readability demonstrated an inverse pattern relative to expert-rated quality. OpenEvidence demonstrated the lowest readability (Flesch-Kincaid Grade Level 17.5; Flesch Reading Ease 2.2), corresponding to a postgraduate reading level, whereas general-purpose LLMs produced more accessible responses at a sixth–seventh grade reading level. Conclusions: The quality of tinnitus information varies substantially across digital platforms. While GenAI systems generally outperform web search, deficiencies in completeness persist. Readability analysis revealed an inverse relationship between expert-rated quality and response accessibility, suggesting that clinician and patient assessments of informational value may not always align. These findings highlight the need for continued evaluation and clinician oversight to ensure safe, comprehensive, and accessible patient-facing information.