SHSteven Haworth

Steven Haworth

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Steven Haworth has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Occupational Radiation Exposure During Robotic-Assisted Navigational Bronchoscopy

    by Vishwajit Hegde, Tariq Odeh, Samuel L. Windham, Steven Haworth, Ross Crawford, Lucas Pitts, Maykol Postigo

    Background: Robotic-assisted bronchoscopy (RAB) uses fluoroscopy and cone-beam CT (CBCT), which can expose procedural staff to ionizing radiation. Real-time, role-specific occupational dosimetry data from live RAB procedures remain limited. Methods: We prospectively collected continuous personal dosimetry from attending physicians, anesthesia providers, and scrub nurses during 51 consecutive RAB procedures at a single academic center using a standardized low-dose imaging protocol and shielding. Collar-badge readings were converted to estimated effective dose using a conservative upper-bound conversion factor. Role-specific dose distributions were compared, and scenario-based annual estimates were generated by bootstrap resampling. Results: Median per-procedure estimated dose was 1.27 µSv for attending physicians, 0.58 µSv for anesthesia providers, and 0.55 µSv for scrub nurses. Exposure differed by role, with the primary operator receiving the highest dose. CBCT cases were associated with higher staff and patient radiation measures but also involved smaller lesions and longer fluoroscopy times, indicating confounding by procedural complexity. Patient BMI was independently associated with physician exposure. Projected annual exposures remained well below the ICRP 20 mSv occupational limit across all roles. Conclusion: Occupational radiation exposure during RAB was low across all staff roles under an optimized imaging workflow. Role-specific dosimetry captures exposure differences across the procedural team and supports standardized low-dose imaging and shielding as core safety practices.

  • Diagnostic Yield and Molecular Testing Adequacy of Transbronchial Cryoprobe Biopsy Versus Needle Aspiration in Robotic Bronchoscopy

    by Tariq Odeh, Vishwajit Hegde, Maggie Chen, Steven Haworth, Maykol Postigo

    Background: In the AQuIRE trial, most cases (83.6%) did not involve transbronchial needle aspiration (TBNA), often underutilized due to challenges in accessing peripheral pulmonary lesions (PPLs). Advances in robotic bronchoscopy with shape-sensing technology (ssRAB) have mitigated these challenges, but the optimal number of needle and cryoprobe passes for reliable diagnosis remains undefined. Methods: This retrospective study compares the diagnostic yield (DY) of TBNA and transbronchial cryoprobe biopsy (TBCB) and their adequacy for molecular testing in PPLs. We performed a retrospective analysis of 166 patients who underwent ssRAB with both TBNA and TBCB from May to August 2024. Fisher exact tests and McNemar χ 2 tests were used to compare prevalence differences in DY and molecular testing adequacy between discordant cases. Odds ratios (OR) and 95% CIs of associations between the number of passes and diagnostic yield and rates of obtaining adequate samples for molecular testing were obtained using generalized linear mixed models (GLMMs) with a logit link. Results: TBCB demonstrated a higher diagnostic rate than TBNA (89% vs. 80%, OR=2.04, 95% CI=1.06-4.03; P =0.032), as well as better rates of obtaining samples adequate for molecular testing (60% vs. 20%, OR=5.94, 95% CI=2.31-16.38, P χ 2 =9.33, P =0.002) of cases where TBNA failed to provide a diagnosis and was able to obtain adequate samples for molecular testing in 42% ( χ 2 =15.06, P <0.001) of cases where TBNA was unable to. Conclusion: TBCB suggests a higher diagnostic yield and higher cellular adequacy for molecular testing compared with TBNA, underscoring its potential value as a reliable and versatile diagnostic tool in PPLs.