Steven Haworth
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Steven Haworth has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Maykol Postigo Jasahui
Division of Pulmonary and Critical Care Medicine, University of Kansas Medical Center
2 shared publications - Lucas R. Pitts
Division of Pulmonary and Critical Care Medicine, University of Kansas Medical Center
1 shared publication - Maggie Chen
Department of Medicine, University of Kansas Medical Center, Kansas City, KS
1 shared publication - Ross Crawford
Department of Radiation Safety, University of Kansas Health System, Kansas City, KS
1 shared publication Samuel L. Windham
Division of Pulmonary and Critical Care Medicine, University of Kansas Medical Center
1 shared publication- Tariq Odeh
Department of Medicine, Division of Pulmonary and Critical Care
1 shared publication
Latest Publications
- 27 October 2026
- Published by Wolters Kluwer Health in Journal of Bronchology & Interventional Pulmonology
- Vol. 34 (1)
Occupational Radiation Exposure During Robotic-Assisted Navigational Bronchoscopy
Background: Robotic-assisted bronchoscopy (RAB) uses fluoroscopy and cone-beam CT (CBCT), which can expose procedural staff to ionizing radiation. Real-time, role-specific occupational dosimetry data from live RAB procedures remain limited. Methods: We prospectively collected continuous personal dosimetry from attending physicians, anesthesia providers, and scrub nurses during 51 consecutive RAB procedures at a single academic center using a standardized low-dose imaging protocol and shielding. Collar-badge readings were converted to estimated effective dose using a conservative upper-bound conversion factor. Role-specific dose distributions were compared, and scenario-based annual estimates were generated by bootstrap resampling. Results: Median per-procedure estimated dose was 1.27 µSv for attending physicians, 0.58 µSv for anesthesia providers, and 0.55 µSv for scrub nurses. Exposure differed by role, with the primary operator receiving the highest dose. CBCT cases were associated with higher staff and patient radiation measures but also involved smaller lesions and longer fluoroscopy times, indicating confounding by procedural complexity. Patient BMI was independently associated with physician exposure. Projected annual exposures remained well below the ICRP 20 mSv occupational limit across all roles. Conclusion: Occupational radiation exposure during RAB was low across all staff roles under an optimized imaging workflow. Role-specific dosimetry captures exposure differences across the procedural team and supports standardized low-dose imaging and shielding as core safety practices.
- 27 October 2026
- Published by Wolters Kluwer Health in Journal of Bronchology & Interventional Pulmonology
- Vol. 34 (1)
Occupational Radiation Exposure During Robotic-Assisted Navigational Bronchoscopy
Background: Robotic-assisted bronchoscopy (RAB) uses fluoroscopy and cone-beam CT (CBCT), which can expose procedural staff to ionizing radiation. Real-time, role-specific occupational dosimetry data from live RAB procedures remain limited. Methods: We prospectively collected continuous personal dosimetry from attending physicians, anesthesia providers, and scrub nurses during 51 consecutive RAB procedures at a single academic center using a standardized low-dose imaging protocol and shielding. Collar-badge readings were converted to estimated effective dose using a conservative upper-bound conversion factor. Role-specific dose distributions were compared, and scenario-based annual estimates were generated by bootstrap resampling. Results: Median per-procedure estimated dose was 1.27 µSv for attending physicians, 0.58 µSv for anesthesia providers, and 0.55 µSv for scrub nurses. Exposure differed by role, with the primary operator receiving the highest dose. CBCT cases were associated with higher staff and patient radiation measures but also involved smaller lesions and longer fluoroscopy times, indicating confounding by procedural complexity. Patient BMI was independently associated with physician exposure. Projected annual exposures remained well below the ICRP 20 mSv occupational limit across all roles. Conclusion: Occupational radiation exposure during RAB was low across all staff roles under an optimized imaging workflow. Role-specific dosimetry captures exposure differences across the procedural team and supports standardized low-dose imaging and shielding as core safety practices.
- 3 August 2026
- Published by Wolters Kluwer Health in Journal of Bronchology & Interventional Pulmonology
- Vol. 33 (4)
Diagnostic Yield and Molecular Testing Adequacy of Transbronchial Cryoprobe Biopsy Versus Needle Aspiration in Robotic Bronchoscopy
Background: In the AQuIRE trial, most cases (83.6%) did not involve transbronchial needle aspiration (TBNA), often underutilized due to challenges in accessing peripheral pulmonary lesions (PPLs). Advances in robotic bronchoscopy with shape-sensing technology (ssRAB) have mitigated these challenges, but the optimal number of needle and cryoprobe passes for reliable diagnosis remains undefined. Methods: This retrospective study compares the diagnostic yield (DY) of TBNA and transbronchial cryoprobe biopsy (TBCB) and their adequacy for molecular testing in PPLs. We performed a retrospective analysis of 166 patients who underwent ssRAB with both TBNA and TBCB from May to August 2024. Fisher exact tests and McNemar χ 2 tests were used to compare prevalence differences in DY and molecular testing adequacy between discordant cases. Odds ratios (OR) and 95% CIs of associations between the number of passes and diagnostic yield and rates of obtaining adequate samples for molecular testing were obtained using generalized linear mixed models (GLMMs) with a logit link. Results: TBCB demonstrated a higher diagnostic rate than TBNA (89% vs. 80%, OR=2.04, 95% CI=1.06-4.03; P =0.032), as well as better rates of obtaining samples adequate for molecular testing (60% vs. 20%, OR=5.94, 95% CI=2.31-16.38, P χ 2 =9.33, P =0.002) of cases where TBNA failed to provide a diagnosis and was able to obtain adequate samples for molecular testing in 42% ( χ 2 =15.06, P <0.001) of cases where TBNA was unable to. Conclusion: TBCB suggests a higher diagnostic yield and higher cellular adequacy for molecular testing compared with TBNA, underscoring its potential value as a reliable and versatile diagnostic tool in PPLs.
- 3 August 2026
- Published by Wolters Kluwer Health in Journal of Bronchology & Interventional Pulmonology
- Vol. 33 (4)
Diagnostic Yield and Molecular Testing Adequacy of Transbronchial Cryoprobe Biopsy Versus Needle Aspiration in Robotic Bronchoscopy
Background: In the AQuIRE trial, most cases (83.6%) did not involve transbronchial needle aspiration (TBNA), often underutilized due to challenges in accessing peripheral pulmonary lesions (PPLs). Advances in robotic bronchoscopy with shape-sensing technology (ssRAB) have mitigated these challenges, but the optimal number of needle and cryoprobe passes for reliable diagnosis remains undefined. Methods: This retrospective study compares the diagnostic yield (DY) of TBNA and transbronchial cryoprobe biopsy (TBCB) and their adequacy for molecular testing in PPLs. We performed a retrospective analysis of 166 patients who underwent ssRAB with both TBNA and TBCB from May to August 2024. Fisher exact tests and McNemar χ 2 tests were used to compare prevalence differences in DY and molecular testing adequacy between discordant cases. Odds ratios (OR) and 95% CIs of associations between the number of passes and diagnostic yield and rates of obtaining adequate samples for molecular testing were obtained using generalized linear mixed models (GLMMs) with a logit link. Results: TBCB demonstrated a higher diagnostic rate than TBNA (89% vs. 80%, OR=2.04, 95% CI=1.06-4.03; P =0.032), as well as better rates of obtaining samples adequate for molecular testing (60% vs. 20%, OR=5.94, 95% CI=2.31-16.38, P χ 2 =9.33, P =0.002) of cases where TBNA failed to provide a diagnosis and was able to obtain adequate samples for molecular testing in 42% ( χ 2 =15.06, P <0.001) of cases where TBNA was unable to. Conclusion: TBCB suggests a higher diagnostic yield and higher cellular adequacy for molecular testing compared with TBNA, underscoring its potential value as a reliable and versatile diagnostic tool in PPLs.