Sid Thatham
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sid Thatham has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Aayush Kumar
Xtended Reality (XR) Lab, Digital Futures, University of Cincinnati, Cincinnati, OH 45206, USA
2 shared publications - Mikhail Nikolaenko
Xtended Reality (XR) Lab, Digital Futures, University of Cincinnati, Cincinnati, OH 45206, USA
2 shared publications - Ming Tang
Xtended Reality (XR) Lab, Digital Futures, University of Cincinnati, Cincinnati, OH 45206, USA
2 shared publications
Latest Publications
- Open Access
- 5 November 2026
- Published by MDPI AG in Architecture
- Vol. 6 (4) , 205
AI-Powered Digital Twin for Sustainable Campus Facility Management
University campus buildings consume significant energy through chilled water (CHW) systems, yet facility and energy managers lack tools that connect sensor data to actionable, spatially grounded decisions without requiring programming expertise. We present BearcatAI, an end-to-end analytics platform developed at the University of Cincinnati (UC) that unifies machine learning demand prediction, a large language model (LLM) conversational interface, and an interactive 3D campus visualization derived from geographic information system (GIS) data. All models were trained and evaluated on 271 days of daily meter data collected across the UC building portfolio (June 2025–February 2026); ten years of monthly CHW records (July 2015–July 2025) provided long-term context only. An ensemble of XGBoost and Random Forest models achieves an in-sample , mean absolute percentage error (MAPE) (inflated by near-zero winter readings), and normalized mean bias error on DAAP (College of Design, Architecture, Art, and Planning), the priority building identified by the UC utility engineering team. Beyond building-specific models, we introduce use-type models that pool buildings by functional category (Academic, Research, Administrative, Housing, Recreation, Medical) without any building-specific identity features. Leave-One-Building-Out (LOBO) cross-validation shows that the Research type model generalizes to unseen research buildings with median , and the Academic model achieves on DAAP without having seen it during training, whereas medical and hospital types do not generalize, demonstrating the feasibility of functional type models as campus-scale benchmarking tools within the study dataset. A natural language interface powered by BearcatGPT, UC’s hosted instance of GPT-4.1, allows utility managers to query anomalies, request forecasts, and generate building charts through conversation. Anomalous buildings are automatically highlighted in a 3D campus model spanning UC Main Campus, Medical Campus, and Digital Futures. The results are limited to a single campus and observation period; user evaluation and a robotic inspection module under development remain future work.- 5 November 2026
- Published by MDPI AG in Architecture
- Vol. 6 (4) , 205
Open AccessAI-Powered Digital Twin for Sustainable Campus Facility Management
University campus buildings consume significant energy through chilled water (CHW) systems, yet facility and energy managers lack tools that connect sensor data to actionable, spatially grounded decisions without requiring programming expertise. We present BearcatAI, an end-to-end analytics platform developed at the University of Cincinnati (UC) that unifies machine learning demand prediction, a large language model (LLM) conversational interface, and an interactive 3D campus visualization derived from geographic information system (GIS) data. All models were trained and evaluated on 271 days of daily meter data collected across the UC building portfolio (June 2025–February 2026); ten years of monthly CHW records (July 2015–July 2025) provided long-term context only. An ensemble of XGBoost and Random Forest models achieves an in-sample , mean absolute percentage error (MAPE) (inflated by near-zero winter readings), and normalized mean bias error on DAAP (College of Design, Architecture, Art, and Planning), the priority building identified by the UC utility engineering team. Beyond building-specific models, we introduce use-type models that pool buildings by functional category (Academic, Research, Administrative, Housing, Recreation, Medical) without any building-specific identity features. Leave-One-Building-Out (LOBO) cross-validation shows that the Research type model generalizes to unseen research buildings with median , and the Academic model achieves on DAAP without having seen it during training, whereas medical and hospital types do not generalize, demonstrating the feasibility of functional type models as campus-scale benchmarking tools within the study dataset. A natural language interface powered by BearcatGPT, UC’s hosted instance of GPT-4.1, allows utility managers to query anomalies, request forecasts, and generate building charts through conversation. Anomalous buildings are automatically highlighted in a 3D campus model spanning UC Main Campus, Medical Campus, and Digital Futures. The results are limited to a single campus and observation period; user evaluation and a robotic inspection module under development remain future work. - Open Access
- 29 September 2026
- Published by MDPI AG in Preprints.org
AI-Powered Digital Twin for Sustainable Campus Facility Management
University campus buildings consume significant energy through chilled water (CHW) systems, yet facility and energy managers lack tools that connect sensor data to actionable, spatially grounded decisions without requiring programming expertise. We present BearcatAI, an end-to-end analytics platform developed at the University of Cincinnati that unifies machine learning demand prediction, a large language model (LLM) conversational interface, an interactive 3D GIS-derived campus visualization, and a ROS-based robotic inspection system into a single web-accessible workflow. The platform is informed by ten years of monthly CHW records (July 2015–July 2025) and validated against 271 days of daily meter data across 70 UC buildings (June 2025–February 2026). An ensemble of XGBoost and Random Forest models achieves R2=0.987 and MAPE =21.8% on DAAP, the priority building identified by the UC utility engineering team. Beyond building-specific models, we introduce use-type models that pool buildings by functional category (Academic, Research, Administrative, Housing, Recreation, Medical) and learn a transferable CHW intensity pattern without any building-specific identity features. Leave-One-Building-Out (LOBO) cross-validation shows that the Research type model generalizes to unseen research buildings with median R2=0.911, and the Academic model achieves R2=0.918 on DAAP without having seen it during training, validating the hypothesis that a functional type model can serve as a generalizable benchmark for campus CHW consumption. A natural language interface powered by BearcatGPT, UC’s hosted instance of GPT-4.1, free for students and faculty, allows utility managers to query anomalies, request forecasts, and generate building charts through conversation. Anomalous buildings are automatically highlighted in a 3D campus model spanning UC Main Campus, Medical Campus, and Digital Futures. A ROS-based inspection robot, trained in a Digital Futures digital twin via reinforcement learning, is under ongoing development and is described as a future integration target. The platform is designed for open deployment on JetStream2 academic cloud infrastructure.
- 29 September 2026
- Published by MDPI AG in Preprints.org
Open AccessAI-Powered Digital Twin for Sustainable Campus Facility Management
University campus buildings consume significant energy through chilled water (CHW) systems, yet facility and energy managers lack tools that connect sensor data to actionable, spatially grounded decisions without requiring programming expertise. We present BearcatAI, an end-to-end analytics platform developed at the University of Cincinnati that unifies machine learning demand prediction, a large language model (LLM) conversational interface, an interactive 3D GIS-derived campus visualization, and a ROS-based robotic inspection system into a single web-accessible workflow. The platform is informed by ten years of monthly CHW records (July 2015–July 2025) and validated against 271 days of daily meter data across 70 UC buildings (June 2025–February 2026). An ensemble of XGBoost and Random Forest models achieves R2=0.987 and MAPE =21.8% on DAAP, the priority building identified by the UC utility engineering team. Beyond building-specific models, we introduce use-type models that pool buildings by functional category (Academic, Research, Administrative, Housing, Recreation, Medical) and learn a transferable CHW intensity pattern without any building-specific identity features. Leave-One-Building-Out (LOBO) cross-validation shows that the Research type model generalizes to unseen research buildings with median R2=0.911, and the Academic model achieves R2=0.918 on DAAP without having seen it during training, validating the hypothesis that a functional type model can serve as a generalizable benchmark for campus CHW consumption. A natural language interface powered by BearcatGPT, UC’s hosted instance of GPT-4.1, free for students and faculty, allows utility managers to query anomalies, request forecasts, and generate building charts through conversation. Anomalous buildings are automatically highlighted in a 3D campus model spanning UC Main Campus, Medical Campus, and Digital Futures. A ROS-based inspection robot, trained in a Digital Futures digital twin via reinforcement learning, is under ongoing development and is described as a future integration target. The platform is designed for open deployment on JetStream2 academic cloud infrastructure.