Anussan Nadarasa
Anussan Nadarasa has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Aadam Ahmad
King's College London School of Medicine
1 shared publication - Behrad Vakili
Department of Trauma and Orthopaedics Surgery, Buckinghamshire Healthcare NHS Trust, Aylesbury, UK
1 shared publication - Mahsa Zolfaghari
Department of Ophthalmology, St Thomas’ Hospital, Guy’s and St Thomas’ NHS Foundation Trust, London, UK
1 shared publication - Sabeeh Syed1 shared publication
Latest Publications
- Open Access
- 18 September 2026
- Published by JMIR Publications Inc. in JMIR Preprints
Correlated Errors and the Limits of Multimodel Consensus in Radiologic Anatomy Identification by Multimodal Large Language Models: Comparative Evaluation Study (Preprint)
BACKGROUND Trainees and educators increasingly ask multimodal large language models (LLMs) to name arrowed anatomical structures on radiological images. When uncertain, they often check another LLM. That action assumes model errors are independent; this is an untested assumption for this task that learners cannot assess unaided, with risk of automation bias. OBJECTIVE We measured how accurately 5 multimodal LLMs identify indicated structures in free text, quantified the independence of their errors, and evaluated the panel as a measuring instrument to establish what its agreement licenses. METHODS In this comparative evaluation, 5 LLMs from 4 developers (4 frontier, 1 lightweight: GPT-5.5 Pro and Instant, Claude Opus 4.8, Gemini 3.1 Pro, Meta Muse Spark) answered 150 First FRCR Anatomy–style items on June 2, 2026. Responses were scored 0, 1, or 2 against the published rubric by an LLM judge and by 2 blinded radiology fellows independently, who agreed on all 750 marks. The comparator was the examination pass standard, Angoff- and Hofstee-referenced to a minimally competent first-year (ST1) trainee and met by 81.3%-94.8% of first-attempt UK candidates, 2021-2025. We quantified error independence using ensemble-diversity measures (pairwise Q, double-fault, effective number of models), generalizability theory with a decision study, and diagnostic-accuracy framing of agreement levels. RESULTS Models obtained 30%-49% (90-147/300) of available marks, none reaching 50%, below every reported pass mark (typically 75%); the 4 frontier models were not separable (Friedman χ2(4)=20.4, P<.001; adjusted P>.99). Errors were not independent: mean pairwise Q 0.58 (95% CI 0.45-0.69; 0 denotes independence), on 45 of 150 items at least 2 models gave the identical wrong answer vs 1.4 expected (P<.001), and the 5 models carried the independent information of 3.59 (95% CI 3.09-4.00). The dominant mechanism was shared fallback to high-prior textbook structures: 55 recurring strings supplied 36.7% of errors. The modal answer of all 5 therefore raised full-mark accuracy only from 48% to 57.3%, a third of the headroom to the 75.3% oracle ceiling, with no majority on 58% of items; 10 models would be needed for dependability 0.80. Unanimity was rare and imprecisely estimated (10/150 items; likelihood ratio 6.70, 95% CI 0.87-51.53); absence of a 3-model majority gave a likelihood ratio of 0.45 (0.34-0.61). CONCLUSIONS Current multimodal LLMs identify radiologic anatomy in free text far below the standard for a minimally competent ST1 trainee. Their errors are correlated, with five models containing the information of 3.59, so agreement is a dependent consensus carrying far less information than independent corroboration. The shared fallback vocabulary suggests this pattern is likely to persist while models share overlapping corpora of training data. For education, the implication is asymmetric and teachable: disagreement, specifically absence of a 3-model majority, is a reliable stopping rule to consult an authoritative source; agreement, including unanimity, is weak evidence and cannot be percieved as verification.
- 18 September 2026
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessCorrelated Errors and the Limits of Multimodel Consensus in Radiologic Anatomy Identification by Multimodal Large Language Models: Comparative Evaluation Study (Preprint)
BACKGROUND Trainees and educators increasingly ask multimodal large language models (LLMs) to name arrowed anatomical structures on radiological images. When uncertain, they often check another LLM. That action assumes model errors are independent; this is an untested assumption for this task that learners cannot assess unaided, with risk of automation bias. OBJECTIVE We measured how accurately 5 multimodal LLMs identify indicated structures in free text, quantified the independence of their errors, and evaluated the panel as a measuring instrument to establish what its agreement licenses. METHODS In this comparative evaluation, 5 LLMs from 4 developers (4 frontier, 1 lightweight: GPT-5.5 Pro and Instant, Claude Opus 4.8, Gemini 3.1 Pro, Meta Muse Spark) answered 150 First FRCR Anatomy–style items on June 2, 2026. Responses were scored 0, 1, or 2 against the published rubric by an LLM judge and by 2 blinded radiology fellows independently, who agreed on all 750 marks. The comparator was the examination pass standard, Angoff- and Hofstee-referenced to a minimally competent first-year (ST1) trainee and met by 81.3%-94.8% of first-attempt UK candidates, 2021-2025. We quantified error independence using ensemble-diversity measures (pairwise Q, double-fault, effective number of models), generalizability theory with a decision study, and diagnostic-accuracy framing of agreement levels. RESULTS Models obtained 30%-49% (90-147/300) of available marks, none reaching 50%, below every reported pass mark (typically 75%); the 4 frontier models were not separable (Friedman χ2(4)=20.4, P<.001; adjusted P>.99). Errors were not independent: mean pairwise Q 0.58 (95% CI 0.45-0.69; 0 denotes independence), on 45 of 150 items at least 2 models gave the identical wrong answer vs 1.4 expected (P<.001), and the 5 models carried the independent information of 3.59 (95% CI 3.09-4.00). The dominant mechanism was shared fallback to high-prior textbook structures: 55 recurring strings supplied 36.7% of errors. The modal answer of all 5 therefore raised full-mark accuracy only from 48% to 57.3%, a third of the headroom to the 75.3% oracle ceiling, with no majority on 58% of items; 10 models would be needed for dependability 0.80. Unanimity was rare and imprecisely estimated (10/150 items; likelihood ratio 6.70, 95% CI 0.87-51.53); absence of a 3-model majority gave a likelihood ratio of 0.45 (0.34-0.61). CONCLUSIONS Current multimodal LLMs identify radiologic anatomy in free text far below the standard for a minimally competent ST1 trainee. Their errors are correlated, with five models containing the information of 3.59, so agreement is a dependent consensus carrying far less information than independent corroboration. The shared fallback vocabulary suggests this pattern is likely to persist while models share overlapping corpora of training data. For education, the implication is asymmetric and teachable: disagreement, specifically absence of a 3-model majority, is a reliable stopping rule to consult an authoritative source; agreement, including unanimity, is weak evidence and cannot be percieved as verification.