Tlotlo Cassandra Setlhare
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tlotlo Cassandra Setlhare has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- George Chimowa
Department of Physics and Astronomy, Botswana International University of Science and Technology, Boseja Ward, Palapye Private Bag 16, Botswana
3 shared publications Atlang Gild Mpolokang
2 shared publicationsSomnath Bhattacharyya
2 shared publications- Atlang Gild Mpolokang
Department of Physics and Astronomy, Botswana International University of Science and Technology, Boseja Ward, Palapye Private Bag 16, Botswana
1 shared publication Atlang Gild. Mpolokang
Department of Physics and Astronomy, Botswana International University of Science and Technology, Palapye, Botswana
1 shared publicationEmmanuel Flahaut
CIRIMAT, Toulouse INP, CNR, Université de Toulouse, 118 Route de Narbonne, 31062, Toulouse Cedex 9, France
1 shared publication
Latest Publications
- Open Access
Chromium-Decorated Double-Walled Carbon Nanotubes for Preferential Room-Temperature Xylene Sensing
Room-temperature discrimination of closely related aromatic volatile organic compounds remains challenging for chemiresistive sensors. Here, chromium-modified double-walled carbon nanotubes (Cr-DWNTs) were prepared using an endohedral filling process and were investigated for preferential xylene detection. X-ray diffraction showed substantial transformation of the CrCl2 precursor to rhombohedral Cr2O3 identified as the dominant crystalline chromium-containing phase. Transmission electron microscopy and elemental analysis supported association of the chromium-containing phase with the DWNT structure. Raman spectroscopy showed retention of the characteristic D, G, and 2D bands with only a small change in the ratio, indicating preservation of the graphitic framework after chromium modification. Hall-effect measurements showed positive Hall coefficients for both pristine DWNTs and Cr-DWNTs, confirming hole-dominated transport, while Cr-DWNTs exhibited a lower apparent Hall carrier concentration together with substantially higher carrier mobility and conductivity. Cr-DWNTs exhibited a pronounced preferential response toward xylene over 0.1–10 ppm. The xylene response increased from approximately 0.96% at 0.1 ppm to 5.93% at 10 ppm and was enhanced by approximately 1.9–2.6 times relative to pristine DWNTs. Within 0.1–1 ppm, the low-concentration xylene sensitivity was 2.36% ppm−1 (), with a calculated limit of detection of approximately 37 ppb. The enhanced response is attributed to the combination of the intrinsic affinity of graphitic carbon toward methyl-substituted aromatics and interfacial electronic transduction within the DWNT network. These results demonstrate that chromium modification provides an effective strategy for amplifying room-temperature xylene selectivity in CNT-based chemiresistive sensors.Open AccessChromium-Decorated Double-Walled Carbon Nanotubes for Preferential Room-Temperature Xylene Sensing
Room-temperature discrimination of closely related aromatic volatile organic compounds remains challenging for chemiresistive sensors. Here, chromium-modified double-walled carbon nanotubes (Cr-DWNTs) were prepared using an endohedral filling process and were investigated for preferential xylene detection. X-ray diffraction showed substantial transformation of the CrCl2 precursor to rhombohedral Cr2O3 identified as the dominant crystalline chromium-containing phase. Transmission electron microscopy and elemental analysis supported association of the chromium-containing phase with the DWNT structure. Raman spectroscopy showed retention of the characteristic D, G, and 2D bands with only a small change in the ratio, indicating preservation of the graphitic framework after chromium modification. Hall-effect measurements showed positive Hall coefficients for both pristine DWNTs and Cr-DWNTs, confirming hole-dominated transport, while Cr-DWNTs exhibited a lower apparent Hall carrier concentration together with substantially higher carrier mobility and conductivity. Cr-DWNTs exhibited a pronounced preferential response toward xylene over 0.1–10 ppm. The xylene response increased from approximately 0.96% at 0.1 ppm to 5.93% at 10 ppm and was enhanced by approximately 1.9–2.6 times relative to pristine DWNTs. Within 0.1–1 ppm, the low-concentration xylene sensitivity was 2.36% ppm−1 (), with a calculated limit of detection of approximately 37 ppb. The enhanced response is attributed to the combination of the intrinsic affinity of graphitic carbon toward methyl-substituted aromatics and interfacial electronic transduction within the DWNT network. These results demonstrate that chromium modification provides an effective strategy for amplifying room-temperature xylene selectivity in CNT-based chemiresistive sensors. - Open Access
- 6 May 2026
- Published by Springer Nature in Discover Artificial Intelligence
- Vol. 6 (1)
Discriminative analysis of breath profiles in tuberculosis patients using machine learning classifiers
- 6 May 2026
- Published by Springer Nature in Discover Artificial Intelligence
- Vol. 6 (1)
Open AccessDiscriminative analysis of breath profiles in tuberculosis patients using machine learning classifiers
- Open Access
- 18 July 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 26085
Determination of lung cancer exhaled breath biomarkers using machine learning-a new analysis framework
Exhaled breath samples of lung cancer patients (LC), tuberculosis (TB) patients and asymptomatic controls (C) were analyzed using gas chromatography-mass spectrometry (GC-MS). Ten volatile organic compounds (VOCs) were identified as possible biomarkers after confounders were statistically eliminated to enhance biomarker specificity. The diagnostic potential of these possible biomarkers was evaluated using multiple machine learning models and their performance for classifying patients and controls was compared. Partial least squares-discriminant analysis (PLS-DA) emerged as the best-performing model for separating lung cancer from controls, with a recall (sensitivity) of 82%, precision of 90%, accuracy of 80% and F1-score of 86%. To further validate this model, TB data was introduced as a confounding disease, and the model achieved precision, recall, accuracy and F1-score of 88% each, in distinguishing lung cancer from TB. These findings address the inter-disease variability and underscores the reliability of the reported VOCs as potential biomarkers of lung cancer. This study establishes a new framework integrating machine learning and confounder elimination for biomarker confirmation.
- 18 July 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 26085
Open AccessDetermination of lung cancer exhaled breath biomarkers using machine learning-a new analysis framework
Exhaled breath samples of lung cancer patients (LC), tuberculosis (TB) patients and asymptomatic controls (C) were analyzed using gas chromatography-mass spectrometry (GC-MS). Ten volatile organic compounds (VOCs) were identified as possible biomarkers after confounders were statistically eliminated to enhance biomarker specificity. The diagnostic potential of these possible biomarkers was evaluated using multiple machine learning models and their performance for classifying patients and controls was compared. Partial least squares-discriminant analysis (PLS-DA) emerged as the best-performing model for separating lung cancer from controls, with a recall (sensitivity) of 82%, precision of 90%, accuracy of 80% and F1-score of 86%. To further validate this model, TB data was introduced as a confounding disease, and the model achieved precision, recall, accuracy and F1-score of 88% each, in distinguishing lung cancer from TB. These findings address the inter-disease variability and underscores the reliability of the reported VOCs as potential biomarkers of lung cancer. This study establishes a new framework integrating machine learning and confounder elimination for biomarker confirmation.
- Open Access
- 12 February 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-9
New volatile organic compounds from the exhaled breath of active tuberculosis patients
Tuberculosis (TB) remains a leading global cause of mortality, necessitating the development of innovative diagnostic approaches for early and accurate detection. Existing diagnostic methods are invasive, time-intensive, and contribute to delays in diagnosis, thereby exacerbating disease progression in patients and facilitating community transmission. To address these limitations, this study investigated human breath samples to identify volatile organic compounds (VOCs) associated with active TB as potential non-invasive biomarkers. VOCs were analysed using gas chromatography-mass spectrometry (GC-MS), supported by AMDIS and OpenChrom software for compound identification. The findings revealed the presence of previously unreported VOCs associated to breath samples from patients with active TB and multidrug-resistant TB (MDR-TB), which were absent in control participants without TB symptoms. Furthermore, the results suggest the feasibility of differentiating MDR-TB from active TB based on breath VOC profiles, marking a novel observation. These findings underpin the development of a non-invasive breathalyser diagnostic device for TB, with the potential to enhance disease management and reduce transmission.
- 12 February 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-9
Open AccessNew volatile organic compounds from the exhaled breath of active tuberculosis patients
Tuberculosis (TB) remains a leading global cause of mortality, necessitating the development of innovative diagnostic approaches for early and accurate detection. Existing diagnostic methods are invasive, time-intensive, and contribute to delays in diagnosis, thereby exacerbating disease progression in patients and facilitating community transmission. To address these limitations, this study investigated human breath samples to identify volatile organic compounds (VOCs) associated with active TB as potential non-invasive biomarkers. VOCs were analysed using gas chromatography-mass spectrometry (GC-MS), supported by AMDIS and OpenChrom software for compound identification. The findings revealed the presence of previously unreported VOCs associated to breath samples from patients with active TB and multidrug-resistant TB (MDR-TB), which were absent in control participants without TB symptoms. Furthermore, the results suggest the feasibility of differentiating MDR-TB from active TB based on breath VOC profiles, marking a novel observation. These findings underpin the development of a non-invasive breathalyser diagnostic device for TB, with the potential to enhance disease management and reduce transmission.