Joan Delpech
Research Subjects
Joan Delpech has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Damien Texier
Institut Clement Ader (ICA) - UMR CNRS 5312, Université de Toulouse, CNRS, INSA, UPS, Mines Albi, ISAE-SUPAERO, Albi Cedex 09, France
1 shared publication - Florian Bugarin
Institut Clément Ader (ICA) Université de Toulouse IMT Mines Albi INSA Toulouse ISAE-SUPAERO CNRS Toulouse France
1 shared publication Thierry Sentenac
1 shared publication- Thierry Sentenac
LAAS-CNRS and Institut Clment Ader (ICA), IMT Mines Albi, INSA, UPS, ISAE,Albi,France
1 shared publication Thomas Pottier
1 shared publication- Tom Fevrier1 shared publication
Latest Publications
- Open Access
- 22 October 2026
- Published by Elsevier in SSRN Electronic Journal
Absolute Albedo Measurement with Photometric Stereo
Photometric Stereo (PS) recovers the surface normal and the albedo of an object from several images acquired from a single viewpoint under varying illumination. In its usual form, the unknown intensity of each light source is absorbed into the estimated albedo, which is therefore recovered only up to an unknown scale factor and cannot be interpreted as a physical reflectance. This paper turns PS into a quantitative, spatially resolved reflectance measurement method. The intensity of each source is calibrated against a Spectralon® white diffuse reflectance standard of certified directional-hemispherical reflectance, independently at each pixel and each wavelength, so that the calibration coefficient also accounts for the photo-response non-uniformity of the sensor and for the spectral response of the whole imaging chain. PS is then performed with the Energy-preserving Oren–Nayar (EON) diffuse reflectance model which, unlike the Lambertian model and earlier Oren–Nayar variants, conserves energy and therefore delivers a physically meaningful albedo together with the surface normals and a diffuse roughness parameter. The method is validated on samples of increasing complexity: Spectralon® standards of nominal reflectance 99 %, 50 % and 20 %, flat samples coated with white and gray diffuse paints, spherical samples coated with the same paints, and a 3D printed replica of the ”Bear” object of the DiLiGenT dataset. The estimated albedo is compared, at 450 nm, 630 nm and 780 nm, with measurements from previous studies and with reference measurements performed with a spectrometer equipped with an integrating sphere.
- 22 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessAbsolute Albedo Measurement with Photometric Stereo
Photometric Stereo (PS) recovers the surface normal and the albedo of an object from several images acquired from a single viewpoint under varying illumination. In its usual form, the unknown intensity of each light source is absorbed into the estimated albedo, which is therefore recovered only up to an unknown scale factor and cannot be interpreted as a physical reflectance. This paper turns PS into a quantitative, spatially resolved reflectance measurement method. The intensity of each source is calibrated against a Spectralon® white diffuse reflectance standard of certified directional-hemispherical reflectance, independently at each pixel and each wavelength, so that the calibration coefficient also accounts for the photo-response non-uniformity of the sensor and for the spectral response of the whole imaging chain. PS is then performed with the Energy-preserving Oren–Nayar (EON) diffuse reflectance model which, unlike the Lambertian model and earlier Oren–Nayar variants, conserves energy and therefore delivers a physically meaningful albedo together with the surface normals and a diffuse roughness parameter. The method is validated on samples of increasing complexity: Spectralon® standards of nominal reflectance 99 %, 50 % and 20 %, flat samples coated with white and gray diffuse paints, spherical samples coated with the same paints, and a 3D printed replica of the ”Bear” object of the DiLiGenT dataset. The estimated albedo is compared, at 450 nm, 630 nm and 780 nm, with measurements from previous studies and with reference measurements performed with a spectrometer equipped with an integrating sphere.