Jin-Song Deng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jin-Song Deng has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
Jian-Yan Wei
Chinese Academy of Sciences
5 shared publications- Li-Ping Xin
Chinese Academy of Sciences
5 shared publications - Chao Wu
Chinese Academy of Sciences
4 shared publications - Yu-Lei Qiu
Chinese Academy of Sciences
4 shared publications Bertrand Cordier
CEA/Paris-Saclay
3 shared publicationsHong-Bo Cai
Chinese Academy of Sciences
3 shared publications
Latest Publications
- 6 October 2026
- Published by IOP Publishing in Research in Astronomy and Astrophysics
- Vol. 26 (10) , 104030
SVOM/C-GFT: Instrumentation and Performance on the SVOM Alerts
The Chinese Ground Follow-up Telescope is an optical facility upgraded to support the Space Variable Objects Monitor (SVOM) mission. Located at the Jilin Observation Station, it is capable of rapidly identifying and monitoring the optical counterparts of gamma-ray bursts. The 1.2 m telescope is equipped with two switchable focal-plane instruments: the prime-focus Large-FOV Transient Imager with CMOS and the Cassegrain-focus Camera with Three Channels. In this paper, we present a system overview, including the observatory, the telescope, the instrumentation, the automated operational framework managed by the Operation Center, and the data processing pipelines. We also report the performance results obtained over one year of SVOM’s post-launch operations. The results demonstrate that the system meets its design specifications and delivers robust observational and operational performance.
- 6 October 2026
- Published by IOP Publishing in Research in Astronomy and Astrophysics
- Vol. 26 (10) , 104030
SVOM/C-GFT: Instrumentation and Performance on the SVOM Alerts
The Chinese Ground Follow-up Telescope is an optical facility upgraded to support the Space Variable Objects Monitor (SVOM) mission. Located at the Jilin Observation Station, it is capable of rapidly identifying and monitoring the optical counterparts of gamma-ray bursts. The 1.2 m telescope is equipped with two switchable focal-plane instruments: the prime-focus Large-FOV Transient Imager with CMOS and the Cassegrain-focus Camera with Three Channels. In this paper, we present a system overview, including the observatory, the telescope, the instrumentation, the automated operational framework managed by the Operation Center, and the data processing pipelines. We also report the performance results obtained over one year of SVOM’s post-launch operations. The results demonstrate that the system meets its design specifications and delivers robust observational and operational performance.
- 6 October 2026
- Published by IOP Publishing in Research in Astronomy and Astrophysics
- Vol. 26 (10) , 104026
SVOM/VT: Real-time Onboard Data Processing
The Space-based Variable Objects Monitor (SVOM) Visible Telescope (VT) is critical for the rapid identification of gamma-ray burst (GRB) optical counterparts, particularly for high-redshift candidates that require immediate infrared spectroscopic follow-up. To address the stringent bandwidth constraints of the Very High Frequency (VHF) downlink while ensuring real-time data availability, we developed the VT Onboard Data Processing Pipeline (VOPP). This paper details the software architecture, algorithms, and hardware implementation of VOPP using a Field-Programmable Gate Array and a CPU. The pipeline performs essential real-time tasks, including image quality assessment, dark and flat-field correction, and optimized image stacking to mitigate cosmic ray contamination and variable background noise. Furthermore, it generates compact source catalogs and highly compressed 1 bit images to facilitate rapid downlink. In-flight performance analysis confirms the pipeline’s robustness, demonstrating the availability of VT VHF data for 78% of promptly slewed SVOM GRBs, with 56% leading to the identification of optical counterparts, typically within 18 minutes post-trigger.
- 6 October 2026
- Published by IOP Publishing in Research in Astronomy and Astrophysics
- Vol. 26 (10) , 104026
SVOM/VT: Real-time Onboard Data Processing
The Space-based Variable Objects Monitor (SVOM) Visible Telescope (VT) is critical for the rapid identification of gamma-ray burst (GRB) optical counterparts, particularly for high-redshift candidates that require immediate infrared spectroscopic follow-up. To address the stringent bandwidth constraints of the Very High Frequency (VHF) downlink while ensuring real-time data availability, we developed the VT Onboard Data Processing Pipeline (VOPP). This paper details the software architecture, algorithms, and hardware implementation of VOPP using a Field-Programmable Gate Array and a CPU. The pipeline performs essential real-time tasks, including image quality assessment, dark and flat-field correction, and optimized image stacking to mitigate cosmic ray contamination and variable background noise. Furthermore, it generates compact source catalogs and highly compressed 1 bit images to facilitate rapid downlink. In-flight performance analysis confirms the pipeline’s robustness, demonstrating the availability of VT VHF data for 78% of promptly slewed SVOM GRBs, with 56% leading to the identification of optical counterparts, typically within 18 minutes post-trigger.
- 5 October 2026
- Published by IOP Publishing in Research in Astronomy and Astrophysics
- Vol. 26 (10) , 104024
SVOM/VT: Preliminary Calibration Analysis
We present the in-orbit calibration of the Visible Telescope (VT), one of the key instruments aboard the Space-based multi-band Variable Objects Monitor (SVOM) mission for gamma-ray burst (GRB) studies. Using Gaia Data Release 3 (DR3) as a reference, the VT achieves an astrometric precision better than 0 . ″ 03 for bright stars, degrading to ∼0 . ″ 25 for faint targets. Shortly after launch, contamination was detected, reducing system transmission by ∼40%. An initial bake-out successfully restored performance, but gradual recontamination caused transmission to decline by ∼20% over the following 100 days before stabilizing. Despite this effect, routine standard star observations maintain precise zero-point calibration, ensuring photometric stability at the 0.02 mag level. Using synthetic stellar spectra, we derived photometric transformations to the Gaia, Sloan Digital Sky Survey, and Johnson–Cousins systems with typical residuals of 0.03 mag. These results demonstrate the VT system’s capability and reliability in calibrating observations of GRBs and other transients.
- 5 October 2026
- Published by IOP Publishing in Research in Astronomy and Astrophysics
- Vol. 26 (10) , 104024
SVOM/VT: Preliminary Calibration Analysis
We present the in-orbit calibration of the Visible Telescope (VT), one of the key instruments aboard the Space-based multi-band Variable Objects Monitor (SVOM) mission for gamma-ray burst (GRB) studies. Using Gaia Data Release 3 (DR3) as a reference, the VT achieves an astrometric precision better than 0 . ″ 03 for bright stars, degrading to ∼0 . ″ 25 for faint targets. Shortly after launch, contamination was detected, reducing system transmission by ∼40%. An initial bake-out successfully restored performance, but gradual recontamination caused transmission to decline by ∼20% over the following 100 days before stabilizing. Despite this effect, routine standard star observations maintain precise zero-point calibration, ensuring photometric stability at the 0.02 mag level. Using synthetic stellar spectra, we derived photometric transformations to the Gaia, Sloan Digital Sky Survey, and Johnson–Cousins systems with typical residuals of 0.03 mag. These results demonstrate the VT system’s capability and reliability in calibrating observations of GRBs and other transients.
- 1 June 2026
- Published by IOP Publishing in Research in Astronomy and Astrophysics
- Vol. 26 (10) , 104023
SVOM/VT: Flight Model Verification and Pre-launch Testing
This paper presents pre-launch testing and calibration results for the SVOM/VT(Space-based Variable Objects Monitor, Visible Telescope) Flight Model (FM), validating its performance under simulated space conditions through thermal vacuum cycling, energy concentration analysis, stray light suppression, and CCD/electronics calibrations (gain, noise, quantum efficiency). The results confirm full compliance with design requirements: stray light suppression achieves point-source transmittance < 10−7 at 30° off-axis, thermal control maintains stable CCD temperatures (-75°C for the red channel, -65°C for the blue channel), and detection sensitivity meets the limiting magnitude of 22.50 (SNR >3 with 300 seconds exposure). Early in-orbit tests further validate performance, yielding limiting magnitudes of 22.70 (V-band, red) and 22.78 (blue), consistent with pre-launch specifications.
- 1 June 2026
- Published by IOP Publishing in Research in Astronomy and Astrophysics
- Vol. 26 (10) , 104023
SVOM/VT: Flight Model Verification and Pre-launch Testing
This paper presents pre-launch testing and calibration results for the SVOM/VT(Space-based Variable Objects Monitor, Visible Telescope) Flight Model (FM), validating its performance under simulated space conditions through thermal vacuum cycling, energy concentration analysis, stray light suppression, and CCD/electronics calibrations (gain, noise, quantum efficiency). The results confirm full compliance with design requirements: stray light suppression achieves point-source transmittance < 10−7 at 30° off-axis, thermal control maintains stable CCD temperatures (-75°C for the red channel, -65°C for the blue channel), and detection sensitivity meets the limiting magnitude of 22.50 (SNR >3 with 300 seconds exposure). Early in-orbit tests further validate performance, yielding limiting magnitudes of 22.70 (V-band, red) and 22.78 (blue), consistent with pre-launch specifications.
- Top Cited Papers
- 1 June 2026
- Published by IOP Publishing in Research in Astronomy and Astrophysics
- Vol. 26 (10) , 104022
\textit{SVOM}/VT: Instrument Overview, Science Objectives, and First-YearPerformance
The 44-cm Visible Telescope (VT) aboard the Space-based Variable Objects Monitor (SVOM) is a dual-band (400–650 nm and 650–1000 nm) instrument designed to detect and characterize the optical counterparts of gamma-ray bursts (GRBs) and other high-energy transients. This paper presents the VT's design, scientific objectives, observation strategies, and space/ground data processing pipelines, alongside its first-year in-orbit performance. In-orbit commissioning tests confirm a sensitivity of 22.5 AB mag (300 s exposure), extendable to ~24 AB mag through stacking. This performance enables the VT to monitor over 100 GRBs in the first year with an exceptional $\sim80\%$ detection rate for SVOM/ECLAIRS-triggered bursts and promptly observed bursts from other missions (e.g., \textit{Swift, Fermi, Einstein Probe (EP)}), outperforming \textit{Swift}/UVOT’s $\sim40\%$ rate. Beyond its exceptional detection efficiency, the VT played a key role in identifying high-redshift GRBs—most notably GRB 250314A (z = 7.3). Its deep upper limits at long wavelengths (up to 1 $\mu m$) were pivotal in guiding follow-up observations with large ground-based telescopes, enabling crucial near-infrared (NIR) detections. With its rapid response, deep sensitivity, and real-time processing capabilities, the VT is a key instrument for GRB research in \textit{SVOM}-era, enabling critical studies of GRB optical afterglows, circumburst environments, relativistic jet dynamics, and the origins of optically dark bursts.- 1 June 2026
- Published by IOP Publishing in Research in Astronomy and Astrophysics
- Vol. 26 (10) , 104022
Top Cited Papers\textit{SVOM}/VT: Instrument Overview, Science Objectives, and First-YearPerformance
The 44-cm Visible Telescope (VT) aboard the Space-based Variable Objects Monitor (SVOM) is a dual-band (400–650 nm and 650–1000 nm) instrument designed to detect and characterize the optical counterparts of gamma-ray bursts (GRBs) and other high-energy transients. This paper presents the VT's design, scientific objectives, observation strategies, and space/ground data processing pipelines, alongside its first-year in-orbit performance. In-orbit commissioning tests confirm a sensitivity of 22.5 AB mag (300 s exposure), extendable to ~24 AB mag through stacking. This performance enables the VT to monitor over 100 GRBs in the first year with an exceptional $\sim80\%$ detection rate for SVOM/ECLAIRS-triggered bursts and promptly observed bursts from other missions (e.g., \textit{Swift, Fermi, Einstein Probe (EP)}), outperforming \textit{Swift}/UVOT’s $\sim40\%$ rate. Beyond its exceptional detection efficiency, the VT played a key role in identifying high-redshift GRBs—most notably GRB 250314A (z = 7.3). Its deep upper limits at long wavelengths (up to 1 $\mu m$) were pivotal in guiding follow-up observations with large ground-based telescopes, enabling crucial near-infrared (NIR) detections. With its rapid response, deep sensitivity, and real-time processing capabilities, the VT is a key instrument for GRB research in \textit{SVOM}-era, enabling critical studies of GRB optical afterglows, circumburst environments, relativistic jet dynamics, and the origins of optically dark bursts.