XHXinjie Huang

Xinjie Huang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xinjie Huang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Simulation Study of Seawater Tritium Measurement with Dual-Diameter Scintillating Fiber Arrays Under Variable Radionuclide Interference

    by Wenyu Cheng, Wenjie Qiu, Xinjie Huang, Husheng Wang, Songjie Shi, Zhirong Guo, Qin Zhang, Jun Yang

    This simulation study uses dual-diameter scintillating fibers and a separately read out reference channel to reduce bias in estimated tritium activity concentration caused by changes in complex seawater backgrounds. The reference signal helps correct background contributions to the tritium estimate. Geant4 responses for seven layouts are coupled to an idealized scintillation–silicon photomultiplier model. Calibration transfer is assessed using 19 literature-matched Sr/Cs pairs in a fixed natural matrix, with composition withheld from the estimator. At baseline optical collection, the 5 mm central cluster reduces absolute concentration bias by 35.5–59.0% across these compositions. For the strongest-interference composition at 100 Bq L−1 tritium, the predicted mean decreases from 133.7 to 113.8 Bq L−1, and the 4 h root mean squared error decreases from 37.0 to 21.9 Bq L−1. The cluster retains 88.8% of the conventional effective response and achieves the lowest calibrated minimum detectable activity concentration (MDA) among the dual-diameter candidates: 47.3–50.6 Bq L−1 at 4 h for the calibration and strongest-interference compositions. Its high-interference error advantage persists under alternative readout assumptions. The conventional array retains a lower calibrated MDA and better precision near calibration. These simulations identify a design compromise between tolerance of changing interference and retention of tritium sensitivity.

  • Open Access

    Seawater Tritium Measurement with Dual-Diameter Scintillating Fiber Arrays Under Variable Radionuclide Interference

    by Wenyu Cheng, Wenjie Qiu, Xinjie Huang, Husheng Wang, Songjie Shi, Zhirong Guo, Qin Zhang, Jun Yang

    Changes in radionuclide composition can bias seawater tritium measurements under fixed calibration. We evaluate dual-diameter scintillating fiber arrays combining 1 mm sensing fibers with a separately read out reference cluster. Geant4 responses for seven layouts are coupled to a scintillation–silicon photomultiplier model. Calibration transfer is assessed using 19 literature-matched Sr/Cs pairs in a fixed natural matrix, with composition withheld from the estimator. At baseline optical collection, the 5 mm central cluster reduces absolute concentration bias by 35.5–59.0% across these compositions. For the strongest-interference composition at 100 Bq L−1 tritium, the predicted mean decreases from 133.7 to 113.8 Bq L−1, and the 4 h root mean squared error decreases from 37.0 to 21.9 Bq L−1. The cluster retains 88.8% of the conventional effective response and achieves the lowest calibrated minimum detectable activity concentration (MDA) among the dual-diameter candidates: 47.3–50.6 Bq L−1 at 4 h for the calibration and strongest-interference compositions. Its high-interference error advantage persists under alternative readout assumptions. The conventional array retains lower calibrated MDA and better precision near calibration. These simulations identify a design compromise between tolerance of changing interference and retention of tritium sensitivity.