RMRemjohn Aron Magtaas

Remjohn Aron Magtaas

*This is an algorithmically generated author record based on publicly available information.

Remjohn Aron Magtaas has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Honey adulteration in the Philippines after the adoption of the ISCIRA method in the national standard

    by Joshua Kian Balaguer, Remjohn Aron Magtaas, Andrei Joshua Yu, Mary Margareth Bauyon-Isidro, Roland Rallos, Norman Mendoza, Angel Vii Bautista

    Honey adulteration is the addition of exogenous sugars to harvested honey, usually done for economic gains. A 2021 study determined that 76 out of 90 (84.4%) local honey products sold in the Philippine market (store and online-bought) are adulterated (Lao et al. 2021). This emphasizes the need for a robust guideline to detect fraudulent honey products for the benefit of consumers, in both economic and health terms. In response, the Philippine National Standards (PNS/BAFS 185:2022) for Honey was revised in 2022 to include stable carbon isotope ratio analysis (ISCIRA), as proposed by DOST-PNRI. This work explores the current state of honey adulteration in the Philippine market as a follow-up to the initial study conducted in 2021. The analytical process followed the validated ISCIRA utilized in the previous market survey. 102 honey samples were obtained from physical retail outlets across various regions in the Philippines, comprising 86 local and 16 imported products. Of these, 58 of 86 (67.4%) local and four of 16 (25.0%) imported samples were classified as non-compliant with the ISCIRA authenticity criteria. Overall, 62 of 102 (60.8%) samples were non-compliant, which was comparable with the 58.0% overall adulteration rate in the 2021 study. Among the non-compliant samples, 39 (62.9%) yielded no extractable protein, while 55 contained >75% apparent C4 sugar content, including 45 samples estimated to be fully substituted by C4 adulterants. These findings underscore the need to strengthen the implementation of the revised Philippine National Standard for honey through sustained market surveillance, regulatory enforcement, and complementary rapid-screening tools.

  • Accurate determination of major and trace elements in nuclear source materials using X-ray fluorescence spectrometry

    by Angel Vii Bautista, Joshua Kian Balaguer, Genie Belle Bulaong, Remjohn Aron Magtaas, Americus Perez, Rachelle Clien Reyes, Joelle Ivane Rojas, Lawrence Glen Sabaria

    Reliable characterization of nuclear source materials requires rapid and defensible methods for measuring major oxides and selected trace elements. This study evaluated portable X-ray fluorescence spectrometry (pXRF) and wavelength-dispersive X-ray fluorescence spectrometry (WDXRF) for geochemical analysis of materials relevant to nuclear source material assessment. Twenty-one certified reference materials, including igneous rocks, sedimentary rocks, sediments, and mineralized reference materials, were prepared as pressed powder pellets and analyzed using a Bruker S1 Titan pXRF and a Rigaku Supermini 200 WDXRF. Calibration performance was assessed by comparing measured and certified values using reporting coverage, linear regression, slope, intercept, and coefficient of determination (R2). For pXRF, manufacturer-provided detection limits and analysis ranges were used as screening references, while WDXRF was evaluated using CRM-based empirical calibration. The pXRF method showed good calibration performance for Cr, Ba, Cu, Ni, Pb, Rb, Sr, Y, Zn, Ca, Fe, K2O, Ti, and Mn, but had insufficient reporting coverage for Nb, Th, U, and V, and poor performance for S, MgO, and P. WDXRF showed stronger performance for major oxides and good calibration for several selected trace elements, including Cr, Cu, Ni, Rb, S, Sr, V, Y, Zn, and Zr. Overall, WDXRF is preferred for quantitative major-oxide analysis and selected elements such as S, V, and Zr, whereas pXRF is useful for rapid screening of selected trace elements. For U and Th, more sensitive complementary techniques such as ICP-MS/MS are recommended.