Ashok Kumar
Ashok Kumar has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Kuldeep Sharma
Maharshi Dayanand University Rohtak (Haryana)
1 shared publication - Ravindra Singh Raghuvanshi
IT, Independent Researcher, Minneapolis, USA, USA
1 shared publication - Sambit Dhar
Independent Researcher, Little Rock, USA, USA
1 shared publication - Vineet Yadav
Quality, Born Inc., Tulsa, USA, USA
1 shared publication
Latest Publications
- Open Access
- 9 October 2026
- Published by MDPI AG in Preprints.org
Measurement Assurance for NDE 4.0: Uncertainty, Traceability, Qualification and Decision Governance
Nondestructive evaluation (NDE) is moving from manually interpreted indications toward connected measurement systems in which sensing, imaging, automated processing, artificial intelligence (AI), and engineering decisions are coupled through a digital thread. This transition increases information availability but also introduces additional points at which measurement meaning, uncertainty, or traceability can be lost. This critical integrative review reframes NDE 4.0 as a metrological-assurance problem and proposes a six-layer architecture spanning the physical measurand, instrument, signal, information, inference, and decision layers. The architecture is combined with an uncertainty map for hybrid physical-digital inspection, a minimum digital evidence record, and a qualification V-model linking intended use to verification, representative validation, bounded autonomy, and post-deployment surveillance. A worked ultrasonic-sizing example illustrates how classical measurement contributions and model-inference uncertainty can be combined without treating AI confidence as a substitute for measurement uncertainty. The synthesis distinguishes metrological traceability from digital provenance, probability of detection from classification metrics, and probabilistic calibration from measurement uncertainty. Cross-sector analysis of aerospace, nuclear, rail, civil infrastructure, and additive manufacturing shows that increasing autonomy raises both information value and evidential burden. The central conclusion is that, for measurement-based engineering decisions, especially in higher-consequence applications, the defensibility of an NDE 4.0 system depends on an adequately traceable, uncertainty-aware, intended-use validation, and auditable sensor-to-decision chain.
- 9 October 2026
- Published by MDPI AG in Preprints.org
Open AccessMeasurement Assurance for NDE 4.0: Uncertainty, Traceability, Qualification and Decision Governance
Nondestructive evaluation (NDE) is moving from manually interpreted indications toward connected measurement systems in which sensing, imaging, automated processing, artificial intelligence (AI), and engineering decisions are coupled through a digital thread. This transition increases information availability but also introduces additional points at which measurement meaning, uncertainty, or traceability can be lost. This critical integrative review reframes NDE 4.0 as a metrological-assurance problem and proposes a six-layer architecture spanning the physical measurand, instrument, signal, information, inference, and decision layers. The architecture is combined with an uncertainty map for hybrid physical-digital inspection, a minimum digital evidence record, and a qualification V-model linking intended use to verification, representative validation, bounded autonomy, and post-deployment surveillance. A worked ultrasonic-sizing example illustrates how classical measurement contributions and model-inference uncertainty can be combined without treating AI confidence as a substitute for measurement uncertainty. The synthesis distinguishes metrological traceability from digital provenance, probability of detection from classification metrics, and probabilistic calibration from measurement uncertainty. Cross-sector analysis of aerospace, nuclear, rail, civil infrastructure, and additive manufacturing shows that increasing autonomy raises both information value and evidential burden. The central conclusion is that, for measurement-based engineering decisions, especially in higher-consequence applications, the defensibility of an NDE 4.0 system depends on an adequately traceable, uncertainty-aware, intended-use validation, and auditable sensor-to-decision chain.