ZZZhenxin Zhao

Zhenxin Zhao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhenxin Zhao has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Preclinical Safety and Efficacy Evaluation of A Novel Phosphorylcholine-Modified Flow Diverter

    by Zhenxin Zhao, Shengzhang Wang

    Background: Flow diverters are widely used to treat intracranial aneurysms, but thrombus formation triggered by foreign-body irritation remains a major complication. SkyVega is a new-generation flow diverter with phosphorylcholine surface modification designed to improve aneurysm occlusion and hemocompatibility. We evaluated aneurysm occlusion, branch vessel preservation, and long-term vascular tissue responses to the phosphorylcholine-modified SkyVega flow diverter in an elastase-induced rabbit aneurysm model. Methods: Twenty-six New Zealand white rabbits were assigned to 30-day, 90-day and 180-day follow-up cohorts. The modified flow diverters were implanted in the parent arteries and abdominal aortas in the experimental group. Unmodified flow diverters implanted in parent arteries served as the 180-day control. Aneurysm occlusion and vessel patency were assessed by digital subtraction angiography (DSA), and biocompatibility was evaluated by histopathology. Results: DSA showed progressive aneurysm occlusion in the experimental group. Parent arteries and covered branches remained patent for up to 180 days, and local tissue reactions were mild in all groups. Phosphorylcholine-modified flow diverters were associated with thinner, concentric, and uniform neointimal growth, whereas controls showed eccentric neointimal hyperplasia and one case of in-stent thrombosis. Conclusion: SkyVega achieves stable, progressive aneurysm occlusion with favorable branch vessel preservation. The phosphorylcholine coating promotes orderly concentric endothelialization and may reduce the risk of thrombosis.

  • Open Access

    Patient-Specific Hemodynamic and Angiographic Evaluation of a Novel Flow-Diverting Device for Intracranial Aneurysms

    by Zhenxin Zhao, Qimin Zhang, Xinzhuo Li, Shengzhang Wang

    Objective: Flow-diverting devices treat intracranial aneurysms by modifying blood exchange between the parent artery and aneurysm. We quantified local flow changes after implantation using patient-specific Computational Fluid Dynamics (CFD). Methods: Three patients were evaluated: two treated with a flow-diverting device alone and one with adjunctive coiling. Patient-specific vascular models were reconstructed from clinical images. Devices and coils were virtually deployed, and steady-state CFD with explicit device geometry compared untreated and treated conditions. Findings were descriptively compared with immediate and 12-month angiography. Results: Device implantation redistributed lesion-region flow and reduced mean velocity by 11.9%, 29.4%, and 6.7% in Cases 1–3. In the giant aneurysm, adjunctive coiling produced additional reductions of 65.1% in sac-averaged velocity and 17.7% in neck-plane velocity. Immediate angiography showed contrast stasis in all cases. At 12 months, all lesions were completely occluded, and parent arteries remained patent, consistent with the direction of flow suppression observed by CFD. Conclusion: Across these representative patient-specific configurations, the device produced local flow redirection while preserving parent-artery patency. Adjunctive coiling provided additional intra-saccular flow suppression in the giant aneurysm case.

  • Open Access

    Patient-Specific Hemodynamic and Angiographic Evaluation of a Novel Flow-Diverting Device for Intracranial Aneurysms

    by Zhenxin Zhao, Qimin Zhang, Xinzhuo Li, Shengzhang Wang

    Objective: Flow-diverting devices treat intracranial aneurysms by modifying blood exchange between the parent artery and aneurysm. We quantified local flow changes after implantation using patient-specific Computational Fluid Dynamics(CFD). Methods: Three patients were evaluated: two treated with a flow-diverting device alone and one with adjunctive coiling. Patient-specific vascular models were reconstructed from clinical images. Devices and coils were virtually deployed, and steady-state CFD with explicit device geometry compared untreated and treated conditions. Findings were descriptively compared with immediate and 12-month angiography. Results: Device implantation redistributed lesion-region flow and reduced mean velocity by 11.9%, 29.4%, and 6.7% in Cases 1-3. In the giant aneurysm, adjunctive coiling produced additional reductions of 65.1% in sac-averaged velocity and 17.7% in neck-plane velocity. Immediate angiography showed contrast stasis in all cases. At 12 months, all lesions were completely occluded and parent arteries remained patent, consistent with the direction of flow suppression observed by CFD. Conclusion: Across these representative patient-specific configurations, the device produced local flow redirection while preserving parent-artery patency. Adjunctive coiling provided additional intra-saccular flow suppression in the giant aneurysm case.