Anhelina Buzhak
Research Subjects
Anhelina Buzhak has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Andriy Sverstiuk
I. HORBACHEVSKY TERNOPIL NATIONAL MEDICAL UNIVERSITY, TERNOPIL, UKRAINE
1 shared publication - Daryna Mruga
Institute of Molecular Biology and Genetics, NAS of Ukraine
1 shared publication - Kseniia Berketa
Institute of Molecular Biology and Genetics, The National Academy of Sciences of Ukraine, 150 Zabolotnoho Str., 03143 Kyiv, Ukraine
1 shared publication - Oleksandr O. Soldatkin
Інститут молекулярної біології і генетики НАН України; Національний технічний університет України «Київський політехнічний інститут імені Ігоря Сікорського», Україна
1 shared publication - Olha V. Soldatkina
Institute of Molecular Biology and Genetics, The National Academy of Sciences of Ukraine, 150 Zabolotnoho Str., 03143 Kyiv, Ukraine
1 shared publication - Yevhen Vakhovskyi
Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine, 150 Zabolotnoho Str., 03680 Kyiv, Ukraine
1 shared publication
Latest Publications
- Open Access
- 30 September 2026
- Published by Odesa I.I. Mechnikov National University in Sensor Electronics and Microsystem Technologies
- Vol. 23 (3) , 37-52
AMPEROMETRIC BIOSENSOR BASED ON A SEMIPERMEABLE POLY-META-PHENYLENEDIAMINE MEMBRANE AND IMMOBILIZED LACTATE OXIDASE FOR HIGHLY ACCURATE L-LACTATE DETERMINATION IN BLOOD SERUM
This paper presents the development and optimization of a biosensor for the accurate and rapid determination of L-lactate concentration in human serum samples. The biosensor uses lactate oxidase (LOx) immobilized in a bovine serum albumin matrix on a platinum transducer, modified with a semipermeable poly-meta-phenylenediamine (PPD) membrane. The PPD membrane minimizes influence from solution parameters like ionic strength and protein content, as well as interferents in blood serum on an analysis result. The biosensor offers a broad linear range (7–1000 μM), low detection limit (7 μM), and short analysis time (less than 10 min), making it suitable for real serum samples measurement. Results showed high correlation with reference methods, with a correlation coefficient of 0.982 in comparison with standard analysis method. Stability tests indicated an RSD of 1.5% and 5.4% for model and real samples analysis, with functionality sustained over 5 days with continuous use. This biosensor is promising for clinical diagnostics due to its speed, accuracy, and stability in measuring L-lactate.
- 30 September 2026
- Published by Odesa I.I. Mechnikov National University in Sensor Electronics and Microsystem Technologies
- Vol. 23 (3) , 37-52
Open AccessAMPEROMETRIC BIOSENSOR BASED ON A SEMIPERMEABLE POLY-META-PHENYLENEDIAMINE MEMBRANE AND IMMOBILIZED LACTATE OXIDASE FOR HIGHLY ACCURATE L-LACTATE DETERMINATION IN BLOOD SERUM
This paper presents the development and optimization of a biosensor for the accurate and rapid determination of L-lactate concentration in human serum samples. The biosensor uses lactate oxidase (LOx) immobilized in a bovine serum albumin matrix on a platinum transducer, modified with a semipermeable poly-meta-phenylenediamine (PPD) membrane. The PPD membrane minimizes influence from solution parameters like ionic strength and protein content, as well as interferents in blood serum on an analysis result. The biosensor offers a broad linear range (7–1000 μM), low detection limit (7 μM), and short analysis time (less than 10 min), making it suitable for real serum samples measurement. Results showed high correlation with reference methods, with a correlation coefficient of 0.982 in comparison with standard analysis method. Stability tests indicated an RSD of 1.5% and 5.4% for model and real samples analysis, with functionality sustained over 5 days with continuous use. This biosensor is promising for clinical diagnostics due to its speed, accuracy, and stability in measuring L-lactate.