Erilane de Souza Marinho
Research Subjects
Erilane de Souza Marinho has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Eliana Cristina Barreto Monteiro
Universidade de Pernambuco
1 shared publication - Eudes de Arimatéa Rocha
Universidade de Pernambuco
1 shared publication - Roberta Richard Pinto
Laboratório de Diversidade de Anfíbios e Répteis; Museu de Arqueologia e Ciências Naturais da Universidade Católica de Pernambuco; Av. Oliveria Lima; 824; 50050-390; Recife; PE; Brazil.; Museu Nacional; Universidade Federal do Rio de Janeiro; Quinta da Boa Vista; São Cristóvão; Rio de Janeiro; 20940-040; Rio de Janeiro; Brazil
1 shared publication - Rômulo Pereira1 shared publication
- Victor Marcelo Estolano de Lima
Polytechnic School, University of Pernambuco, Rua Benfica 455, Recife 50720-001, Brazil
1 shared publication - Willames de Albuquerque Soares
Universidade de Pernambuco
1 shared publication
Latest Publications
- Open Access
- 9 October 2026
- Published by Springer Nature in Journal of Building Pathology and Rehabilitation
- Vol. 11 (5) , 241
Mapping, characterization and quantification of damage in the conservation of built heritage
The Soledade Palace (Palácio da Soledade), a historic building listed by IPHAN in Recife, Brazil, exhibits an advanced state of deterioration on its Northwest and Southwest façades, requiring systematic technical diagnosis to support restoration and conservation interventions. This study mapped, characterized, and quantified the pathological manifestations affecting these façades through an integrated methodological approach, comprising a technical survey with elaboration of a damage map, random statistical sampling with a 50 × 50 cm grid overlay and calculation of the Damage Factor (DF), infrared thermography using a FLIR camera, and prioritization of pathologies through the GUT Method. Statistical treatment employed the Shapiro-Wilk, Mann-Whitney U, and Spearman Correlation tests (α = 0.05). Seven typologies of pathological manifestations were identified on each façade, with moisture and infiltration presenting the highest Damage Factors, 16.33% on the Northwest façade and 30.21% on the Southwest façade, as well as the highest GUT scores. Thermography revealed three predominant thermal-anomaly patterns, roof-related infiltration, generalized subsurface moisture, and rising damp, showing that the actual extent of the damage is considerably greater than that detectable by direct visual inspection. Statistical analysis identified no significant difference between the distributions of the two façades (Mann-Whitney U: p > 0.60) and no correlation between severity and extent of the pathologies (Spearman: ρ ≈ 0.33; p > 0.47), confirming the indispensability of the GUT method as a multicriteria prioritization tool. The integrated approach proved effective and replicable for diagnosing historic buildings in high-humidity climatic contexts.
- 9 October 2026
- Published by Springer Nature in Journal of Building Pathology and Rehabilitation
- Vol. 11 (5) , 241
Open AccessMapping, characterization and quantification of damage in the conservation of built heritage
The Soledade Palace (Palácio da Soledade), a historic building listed by IPHAN in Recife, Brazil, exhibits an advanced state of deterioration on its Northwest and Southwest façades, requiring systematic technical diagnosis to support restoration and conservation interventions. This study mapped, characterized, and quantified the pathological manifestations affecting these façades through an integrated methodological approach, comprising a technical survey with elaboration of a damage map, random statistical sampling with a 50 × 50 cm grid overlay and calculation of the Damage Factor (DF), infrared thermography using a FLIR camera, and prioritization of pathologies through the GUT Method. Statistical treatment employed the Shapiro-Wilk, Mann-Whitney U, and Spearman Correlation tests (α = 0.05). Seven typologies of pathological manifestations were identified on each façade, with moisture and infiltration presenting the highest Damage Factors, 16.33% on the Northwest façade and 30.21% on the Southwest façade, as well as the highest GUT scores. Thermography revealed three predominant thermal-anomaly patterns, roof-related infiltration, generalized subsurface moisture, and rising damp, showing that the actual extent of the damage is considerably greater than that detectable by direct visual inspection. Statistical analysis identified no significant difference between the distributions of the two façades (Mann-Whitney U: p > 0.60) and no correlation between severity and extent of the pathologies (Spearman: ρ ≈ 0.33; p > 0.47), confirming the indispensability of the GUT method as a multicriteria prioritization tool. The integrated approach proved effective and replicable for diagnosing historic buildings in high-humidity climatic contexts.