Lei Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lei Wang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Agudamu
Xilingol Extra-High-Voltage Power Supply Branch of Inner Mongolia Electric Power (Group) Co., Ltd., Hohhot 010020, China
1 shared publication - Caiya Chen
School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China
1 shared publication - Jianli Zhao
Inner Mongolia Power Research Institute Branch, Inner Mongolia Power (Group) Co., Ltd., Hohhot 010020, China
1 shared publication - Jingwen Dong
School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China
1 shared publication - Nan Zhang
Xilingol Extra-High-Voltage Power Supply Branch of Inner Mongolia Electric Power (Group) Co., Ltd., Hohhot 010020, China
1 shared publication - Ruiqian Zhang
School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China
1 shared publication
Latest Publications
- Open Access
- 20 October 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (20) , 10369
Aerodynamic Flow Field and Mechanical Response of a Quad-Bundle Conductor–Stockbridge Damper System Under Sustained Wind Loading
Sustained winds can induce vibration and fretting wear at the hardware connections of quad-bundle conductors fitted with Stockbridge dampers. We developed a coupled dynamic model to characterize the unsteady flow field, aerodynamic loads, structural response, load transfer, and interface wear of this system. Numerical simulations resolved the instantaneous velocity and vorticity fields around the four sub-conductors and quantified their aerodynamic forces, displacements, accelerations, and dynamic tension. A local contact model combined with Archard’s law was then used to calculate interface forces, relative slip, and cumulative wear. Pronounced wake interference produced nonuniform aerodynamic loading among the sub-conductors. Sub-conductor C3 had the largest along-wind aerodynamic-force RMS (1.836 N), while the along-wind displacement RMS values of C1–C4 were 9.95, 6.63, 10.59, and 5.68 cm, respectively. Along-wind motion dominated vertical motion. The tension of C3 varied from 24.883 to 25.445 N over 2–12 s. Dampers D2 and D4 showed the largest displacement and acceleration responses. Cumulative slips at the damper clamp–conductor interface were 10.797, 15.013, 10.645, and 14.989 μm for D1–D4, respectively, and wear was concentrated at this interface. These results link wake interference to damper-interface loading and provide a basis for optimizing damper placement and assessing transmission-line reliability under sustained winds.
- 20 October 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (20) , 10369
Open AccessAerodynamic Flow Field and Mechanical Response of a Quad-Bundle Conductor–Stockbridge Damper System Under Sustained Wind Loading
Sustained winds can induce vibration and fretting wear at the hardware connections of quad-bundle conductors fitted with Stockbridge dampers. We developed a coupled dynamic model to characterize the unsteady flow field, aerodynamic loads, structural response, load transfer, and interface wear of this system. Numerical simulations resolved the instantaneous velocity and vorticity fields around the four sub-conductors and quantified their aerodynamic forces, displacements, accelerations, and dynamic tension. A local contact model combined with Archard’s law was then used to calculate interface forces, relative slip, and cumulative wear. Pronounced wake interference produced nonuniform aerodynamic loading among the sub-conductors. Sub-conductor C3 had the largest along-wind aerodynamic-force RMS (1.836 N), while the along-wind displacement RMS values of C1–C4 were 9.95, 6.63, 10.59, and 5.68 cm, respectively. Along-wind motion dominated vertical motion. The tension of C3 varied from 24.883 to 25.445 N over 2–12 s. Dampers D2 and D4 showed the largest displacement and acceleration responses. Cumulative slips at the damper clamp–conductor interface were 10.797, 15.013, 10.645, and 14.989 μm for D1–D4, respectively, and wear was concentrated at this interface. These results link wake interference to damper-interface loading and provide a basis for optimizing damper placement and assessing transmission-line reliability under sustained winds.