Xiangyang Jiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xiangyang Jiang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Cheng Wang
School of Physics and State Key Laboratory of Nuclear Physics and Technology, Peking University, No. 5 Yiheyuan Road, Beijing 100871
1 shared publication - Cheng-En Liu
Peking University
1 shared publication - Jiawei Bian
School of Physics and State Key Laboratory of Nuclear Physics and Technology, Peking University, No. 5 Yiheyuan Road, Beijing 100871
1 shared publication - Jinning Li
Peking University
1 shared publication - Kaijie Zhou
School of Physics and State Key Laboratory of Nuclear Physics and Technology, Peking University, No. 5 Yiheyuan Road, Beijing 100871
1 shared publication - Qite Li
Peking University
1 shared publication
Latest Publications
- 1 October 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (10) , P10030
Gamma-ray response of a GAGG:Ce scintillator coupled to a 2 × 2 SiPM array
A relatively large 35 × 35 × 20 mm 3 GAGG:Ce scintillator coupled to a 2 × 2 silicon photomultiplier (SiPM) array was characterized for gamma-ray detection, including relative-gain calibration, nonlinear energy response, energy resolution, and timing resolution. The SiPM-array response was well described by a saturation-inspired nonlinear calibration function. For the gain-calibrated individual-readout configuration, energy resolutions of 5.31(9)% at 1173.2 keV and 5.05(8)% at 1332.5 keV were obtained, while offline-simulated summed readout yielded comparable values. Coincidence measurements using 60 Co yielded single-detector timing resolutions of σ = 429(9) ps for individual readout and σ = 425(9) ps for hardware-summed readout. Sensitivity to low-energy gamma rays was also demonstrated by detecting the 59.5-keV line from 24 Am. These results provide a useful performance reference for compact gamma-ray detector designs based on relatively large GAGG:Ce crystals and SiPM-array readout.
- 1 October 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (10) , P10030
Gamma-ray response of a GAGG:Ce scintillator coupled to a 2 × 2 SiPM array
A relatively large 35 × 35 × 20 mm 3 GAGG:Ce scintillator coupled to a 2 × 2 silicon photomultiplier (SiPM) array was characterized for gamma-ray detection, including relative-gain calibration, nonlinear energy response, energy resolution, and timing resolution. The SiPM-array response was well described by a saturation-inspired nonlinear calibration function. For the gain-calibrated individual-readout configuration, energy resolutions of 5.31(9)% at 1173.2 keV and 5.05(8)% at 1332.5 keV were obtained, while offline-simulated summed readout yielded comparable values. Coincidence measurements using 60 Co yielded single-detector timing resolutions of σ = 429(9) ps for individual readout and σ = 425(9) ps for hardware-summed readout. Sensitivity to low-energy gamma rays was also demonstrated by detecting the 59.5-keV line from 24 Am. These results provide a useful performance reference for compact gamma-ray detector designs based on relatively large GAGG:Ce crystals and SiPM-array readout.