Wadha Humaid Said Al Mamari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wadha Humaid Said Al Mamari has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Amal Yousif Al-Yasiri
Department of Basic Sciences, College of Dentistry, University of Baghdad, Baghdad, Iraq
1 shared publication - Ammar A. Hasan
Department of Computer Engineering, College of Engineering, University of Baghdad, Baghdad, Iraq
1 shared publication - Asma Saif Yahya Al-Hadabi
Midwifery and Nursing Tutor at Oman College of Health Science and Higher Institute of Health Specialties, Muscat, Oman
1 shared publication - Eshaq Aziz Awadh Al Mandhari
Graduate School of Technology, Asia Pacific University of Technology and Innovation (APU), Kuala Lumpur, Malaysia
1 shared publication - Issa Nasser Salim Al-Ghatrifi
College of Economics, Management and Information Systems, University of Nizwa, Nizwa, Oman
1 shared publication - Mohamed Abdulnabi
Asia Pacific University of Technology and Innovation
1 shared publication
Latest Publications
- Open Access
- 15 October 2026
- Published by Springer Nature in Discover Artificial Intelligence
- Vol. 6 (1) , 1502
A modified dual-task DenseNet121 with Grad-CAM interpretability for brain tumor classification from MRI
Diagnosing brain tumors from MRI scans is technically challenging but necessary. Early and correct characterization provides direct indications for subsequent treatment of and survival of the patient. While deep learning models show accuracy, most of them focus on just one classification task lacking practical tools for clinical use. We introduce Modified DenseNet121 (Dual-Task framework built on a modified DenseNet121 with a custom regularization stack. This is important to detect abnormalities (Normal vs. Abnormal) and identify three tumor types (Glioma, Meningioma, and Pituitary) in a single architecture. The model incorporates Gradient-weighted Class Activation Mapping (Grad-CAM) for qualitative spatial interpretability, and the model is set up within a PyQt5 desktop research prototype illustrating real-time dual prediction with typical inference latency of 80–130 ms (mean: 185.80 ± 402.83 ms; median: 127.99 ms; 95th percentile: 134.65 ms), probability visualization, Grad-CAM heatmap overlay, and feedback recording from the physician. Elaborate benchmarking experiments were performed against six competing CNN architectures DenseNet121 (baseline), ConvNeXtSmall, ConvNeXtTiny, EfficientNetB0, NASNetMobile and Xception over two large, publicly available MRI datasets: dataset 1, Kaggle, holding 7023 images; and dataset 2, Mendeley, having 12,064 images. Modified DenseNet121 achieved 99.85% binary accuracy and 99.00% multiclass accuracy on dataset 1, and 99.62% binary accuracy and 99.00% multiclass accuracy on dataset 2, achieving competitive performance with all benchmark architectures across both datasets. The zero-shot evaluation on an additional publicly available external MRI dataset achieved 99.75% binary accuracy and 99.20% multiclass accuracy, demonstrating transfer performance under an external evaluation setting. However, because dedicated image-level overlap analysis was not performed, these results are interpreted as evidence of external transfer performance rather than definitive evidence of complete dataset independence. The experimental results demonstrate high predictive performance across two large publicly available datasets and verify the technical feasibility of Modified DenseNet121 as a robust research prototype. This study offers reproducible, interpretable, and research prototype foundation for future clinical translation of neuro-oncological computer-aided diagnosis systems.
- 15 October 2026
- Published by Springer Nature in Discover Artificial Intelligence
- Vol. 6 (1) , 1502
Open AccessA modified dual-task DenseNet121 with Grad-CAM interpretability for brain tumor classification from MRI
Diagnosing brain tumors from MRI scans is technically challenging but necessary. Early and correct characterization provides direct indications for subsequent treatment of and survival of the patient. While deep learning models show accuracy, most of them focus on just one classification task lacking practical tools for clinical use. We introduce Modified DenseNet121 (Dual-Task framework built on a modified DenseNet121 with a custom regularization stack. This is important to detect abnormalities (Normal vs. Abnormal) and identify three tumor types (Glioma, Meningioma, and Pituitary) in a single architecture. The model incorporates Gradient-weighted Class Activation Mapping (Grad-CAM) for qualitative spatial interpretability, and the model is set up within a PyQt5 desktop research prototype illustrating real-time dual prediction with typical inference latency of 80–130 ms (mean: 185.80 ± 402.83 ms; median: 127.99 ms; 95th percentile: 134.65 ms), probability visualization, Grad-CAM heatmap overlay, and feedback recording from the physician. Elaborate benchmarking experiments were performed against six competing CNN architectures DenseNet121 (baseline), ConvNeXtSmall, ConvNeXtTiny, EfficientNetB0, NASNetMobile and Xception over two large, publicly available MRI datasets: dataset 1, Kaggle, holding 7023 images; and dataset 2, Mendeley, having 12,064 images. Modified DenseNet121 achieved 99.85% binary accuracy and 99.00% multiclass accuracy on dataset 1, and 99.62% binary accuracy and 99.00% multiclass accuracy on dataset 2, achieving competitive performance with all benchmark architectures across both datasets. The zero-shot evaluation on an additional publicly available external MRI dataset achieved 99.75% binary accuracy and 99.20% multiclass accuracy, demonstrating transfer performance under an external evaluation setting. However, because dedicated image-level overlap analysis was not performed, these results are interpreted as evidence of external transfer performance rather than definitive evidence of complete dataset independence. The experimental results demonstrate high predictive performance across two large publicly available datasets and verify the technical feasibility of Modified DenseNet121 as a robust research prototype. This study offers reproducible, interpretable, and research prototype foundation for future clinical translation of neuro-oncological computer-aided diagnosis systems.