YLYang Liu

Yang Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yang Liu has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Power System Zoning and Regional Minimum Inertia Requirement Assessment Based on an Improved Spectral Clustering Approach

    by Meng Zhu, Yang Liu, Di An, Xin Hui, Kexin Li, Mo Zhou, Yibo Zhou, Xiaotian Zhang, Chuanliang Cao, Ziyun Wang

    With the large-scale integration of renewable-energy generating units, power-system inertia continues to decline and becomes unevenly distributed in space. Consequently, frequency responses differ markedly among regions following a disturbance, and assessment based on a single center-of-inertia (COI) frequency may conceal local frequency-security risks. This paper proposes a regional inertia assessment and minimum-inertia calculation method based on linearized analysis. First, a generalized relative correlation gain matrix is constructed from a linearized multi-machine model to quantify the dynamic correlation of generator frequency responses. Spectral clustering and the Calinski–Harabasz (CH) index are then used to determine the system partition. Next, synchronous-machine inertia, load-voltage characteristics, virtual inertia, and primary frequency control are considered in stages. The minimum regional inertia requirements are calculated under rate-of-change-of-frequency (RoCoF) and frequency-nadir constraints, and the larger value is taken as the regional inertia threshold. Simulations on the IEEE 10-machine 39-bus system show that the proposed partitions capture regional differences in frequency response and that the estimated values agree closely with the actual aggregated inertia after synchronous machines are replaced. When inertia is configured according to the calculated thresholds, the RoCoF and frequency nadir in every region satisfy the security constraints. Further analysis shows that the minimum inertia requirements under both constraints increase with disturbance magnitude. At a stringent RoCoF limit, the requirement is dominated by the RoCoF constraint; as the limit is relaxed, the frequency-nadir constraint progressively becomes dominant. The proposed method provides a reference for regional inertia assessment and frequency-security control in power systems with high renewable penetration.

  • Open Access

    Coordinated Wind–Storage Frequency Regulation Strategy for Suppressing Frequency Fluctuations

    by Zengyao Tian, Chunshan Li, Rui Sun, Yang Liu, Kexin Li, Xiaotian Zhang, Mo Zhou, Junwen Dai, Tianmeng Yang

    With increasing renewable energy penetration, maintaining active power balance in power systems has become increasingly challenging. Repeated frequency crossings of the primary frequency regulation deadband may degrade frequency quality and shorten the service life of frequency regulation resources. To address this problem, a coordinated wind–storage frequency regulation strategy is proposed to suppress frequency fluctuations. First, a deadband boundary crossing model and evaluation metrics are developed to characterize crossing severity, crossing count, and repeated boundary switching. Second, a risk prediction method combining frequency deviation, rate of change of frequency, and short-term frequency forecasts is proposed to identify potential crossing periods. Based on the predicted risk, a hierarchical coordinated control strategy considering resource suitability is designed. Supercapacitor energy storage preferentially suppresses short-term fluctuations when the frequency approaches the deadband boundary, whereas wind turbines and energy storage jointly provide frequency regulation after the frequency deviation crosses the deadband boundary. Case studies demonstrate that the proposed strategy improves frequency quality, appropriately allocates frequency regulation duties among system resources, and reduces the overall operating cost.

  • Open Access

    A Sustainable Planning and Evaluation Framework for Renewable Energy Bases Under Extreme Weather

    by Zengyao Tian, He Wang, Chunshan Li, Yang Liu, Xiaotian Zhang, Mo Zhou, Zhongfu Tan

    Large-scale renewable energy bases are important for the low-carbon transition and sustainable development of power systems. However, extreme weather may cause prolonged low output or rapid fluctuations in wind and photovoltaic generation, resulting in capacity shortages, limited flexibility, and renewable energy curtailment. To address the inability of conventional planning methods to fully capture extreme-weather risks and multi-timescale flexibility requirements, this paper proposes a sustainable planning and evaluation method for renewable energy bases under extreme weather. First, typical extreme weather events are identified from wind speed and solar irradiance characteristics, and a Copula model combined with CEEMDAN-GRU is used to generate scenarios and forecast available wind and photovoltaic power. Second, a bi-level model integrating upper-level flexibility resource planning and lower-level 8760 h production simulation is developed to jointly optimize long-duration energy storage, coal-fired power, hydrogen conversion, transmission corridors, and demand response under carbon cost and emission constraints. A sustainability-oriented evaluation is then conducted from four dimensions: energy utilization, economic performance, operational flexibility, and environmental performance. Results show that under prolonged low-wind and low-solar conditions, the 48 h average combined wind and photovoltaic output decreases from 1549.11 MW to 811.70 MW, a reduction of 47.60%; during high-wind cut-out events, wind power drops from 3000 MW to 47.45 MW. The CEEMDAN-GRU model achieves average RMSEs of 243.318 MW for wind power and 113.752 MW for photovoltaic power, with R2 values of 0.8626 and 0.9356, respectively. The optimal plan includes 928.60 MW of long-duration energy storage, 536.40 MW of incremental coal-fired capacity, 183.70 MW of electrolyzer capacity, 146.80 MW of hydrogen-based generation, 138.50 MW of transmission expansion, and 48.60 MW of demand response. The proposed method can identify differentiated capacity and flexibility needs under extreme weather and support sustainable and resilient planning through coordinated multi-resource allocation.