Bin Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bin Zhao has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Dawei Wang
Beijing Key Laboratory of Power Supply Assurance Technology and Application for Resilient Power Grids in Megacity, Electric Power Research Institute, State Grid Beijing Electric Power Company, Beijing 100070, China
1 shared publication - Hanqi Dai
Beijing Key Laboratory of Power Supply Assurance Technology and Application for Resilient Power Grids in Megacity, Electric Power Research Institute, State Grid Beijing Electric Power Company, Beijing 100070, China
1 shared publication - Pu Wang
Beijing Key Laboratory of Power Supply Assurance Technology and Application for Resilient Power Grids in Megacity, Electric Power Research Institute, State Grid Beijing Electric Power Company, Beijing 100070, China
1 shared publication - Ruoxi Liu
Beijing Key Laboratory of Power Supply Assurance Technology and Application for Resilient Power Grids in Megacity, Electric Power Research Institute, State Grid Beijing Electric Power Company, Beijing 100070, China
1 shared publication - Zexi Chen
Beijing Key Laboratory of Power Supply Assurance Technology and Application for Resilient Power Grids in Megacity, Electric Power Research Institute, State Grid Beijing Electric Power Company, Beijing 100070, China
1 shared publication
Latest Publications
- Open Access
Voltage-Disturbance Identification and Fast Transfer Control of an IGCT-Based Hybrid Solid-State Transfer Switch
Voltage disturbances in power distribution networks can interrupt power supply to sensitive loads, thus requiring fast and reliable power switching. For low-voltage distribution networks, this study proposes a hybrid solid-state transfer switch based on IGCT, which integrates a magnetically controlled switch and combines voltage disturbance identification and fast switching control methods. The proposed method processes the acquired three-phase voltage waveforms through a hierarchical control architecture. A transient triggering strategy based on dq transform is used to detect abnormal voltage conditions and initiate the switching process, while a deep neural network model with multi-scale feature fusion identifies disturbances from transient voltage features. The identification method was evaluated under simulated noise conditions, and the switching performance was verified on a physical prototype platform. At a signal-to-noise ratio of 20 dB, the proposed model achieved a fault identification accuracy of over 95% under the tested operating conditions. Under single-phase full voltage interruption conditions, the switching time of the prototype was 4.91 ms, approximately 62.2% shorter than the 12.99 ms measured for the tested commercial thyristor-based solid-state transfer switch (Socomec). Under three-phase full voltage interruption conditions, the switching time of the prototype was 6.80 ms. The results show that the proposed hybrid solid-state transfer switch integrates voltage disturbance identification and fast switching control functions, providing a feasible solution for improving the power supply continuity of sensitive loads.
Open AccessVoltage-Disturbance Identification and Fast Transfer Control of an IGCT-Based Hybrid Solid-State Transfer Switch
Voltage disturbances in power distribution networks can interrupt power supply to sensitive loads, thus requiring fast and reliable power switching. For low-voltage distribution networks, this study proposes a hybrid solid-state transfer switch based on IGCT, which integrates a magnetically controlled switch and combines voltage disturbance identification and fast switching control methods. The proposed method processes the acquired three-phase voltage waveforms through a hierarchical control architecture. A transient triggering strategy based on dq transform is used to detect abnormal voltage conditions and initiate the switching process, while a deep neural network model with multi-scale feature fusion identifies disturbances from transient voltage features. The identification method was evaluated under simulated noise conditions, and the switching performance was verified on a physical prototype platform. At a signal-to-noise ratio of 20 dB, the proposed model achieved a fault identification accuracy of over 95% under the tested operating conditions. Under single-phase full voltage interruption conditions, the switching time of the prototype was 4.91 ms, approximately 62.2% shorter than the 12.99 ms measured for the tested commercial thyristor-based solid-state transfer switch (Socomec). Under three-phase full voltage interruption conditions, the switching time of the prototype was 6.80 ms. The results show that the proposed hybrid solid-state transfer switch integrates voltage disturbance identification and fast switching control functions, providing a feasible solution for improving the power supply continuity of sensitive loads.