E. A. Baizhunussov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
E. A. Baizhunussov has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Aiman Ozhikenova
Satbayev University
1 shared publication - Assylbek Ozhiken
RSE “Institute of Mechanics and Engineering named after Academician U.A. Dzholdasbekova”, Kazakhstan
1 shared publication - Ayaulym Assylbekova1 shared publication
- Darkhan Zholtayev
Nazarbayev University, Kazakhstan
1 shared publication - Kuandyk Askarov
National Center for Public Health
1 shared publication - Sain Shaikhiyev
Salidat Kairbekova National Scientific Center for Health Development
1 shared publication
Latest Publications
- Open Access
- 31 October 2026
- Published by Federal Research Institute for Health Organization and Informatics in The CIS Healthcare
- Vol. 2 (3) , 25‑33
Transformation of the operational center of emergency situations of public health of Kazakhstan
Relevance. Modern public health systems are facing an increasing number of complex threats, including infectious diseases, climate-related hazards, environmental exposures, chemical incidents and technological emergencies. The COVID-19 pandemic demonstrated the limitations of predominantly reactive response mechanisms and emphasized the need for systems based on early warning, risk assessment, forecasting and evidence-based decision-making. The purpose of the study: was to develop a conceptual model for transforming the Public Health Emergency Operations Centre of the Republic of Kazakhstan into an integrated analytical and coordination mechanism for managing public health risks. Materials and methods. The study included an analysis of Kazakhstan’s regulatory framework, international WHO approaches to Public Health Emergency Operations Centres, and an assessment of the current functional capacity of the national emergency operations system. Comparative analysis, gap analysis, SWOT analysis, expert assessment and conceptual modelling were applied. Results. The analysis demonstrated that the existing system provides essential emergency monitoring and response functions but faces several structural limitations, including fragmented data sources, insufficient digital integration, lack of standardized risk assessment procedures and limited multidisciplinary workforce capacity. Based on these findings, the authors developed the Integrated Risk-Oriented Public Health Emergency Operations Model. The proposed model integrates five core components: an early warning system, a risk assessment unit, forecasting and scenario modelling, a multi-level response mechanism (L0-L3), and a digital decision-support platform. A key innovation of the model is the introduction of the “3–8–24-hour risk assessment algorithm”, designed to accelerate threat evaluation and decision-making. Conclusion. Implementation of the IMR framework may strengthen Kazakhstan’s public health emergency preparedness by improving early detection, predictive capacity, intersectoral coordination and evidence-based decision-making. The proposed model provides a conceptual foundation for transforming the national emergency operations center into a proactive risk governance platform aligned with global health security principles.
- 31 October 2026
- Published by Federal Research Institute for Health Organization and Informatics in The CIS Healthcare
- Vol. 2 (3) , 25‑33
Open AccessTransformation of the operational center of emergency situations of public health of Kazakhstan
Relevance. Modern public health systems are facing an increasing number of complex threats, including infectious diseases, climate-related hazards, environmental exposures, chemical incidents and technological emergencies. The COVID-19 pandemic demonstrated the limitations of predominantly reactive response mechanisms and emphasized the need for systems based on early warning, risk assessment, forecasting and evidence-based decision-making. The purpose of the study: was to develop a conceptual model for transforming the Public Health Emergency Operations Centre of the Republic of Kazakhstan into an integrated analytical and coordination mechanism for managing public health risks. Materials and methods. The study included an analysis of Kazakhstan’s regulatory framework, international WHO approaches to Public Health Emergency Operations Centres, and an assessment of the current functional capacity of the national emergency operations system. Comparative analysis, gap analysis, SWOT analysis, expert assessment and conceptual modelling were applied. Results. The analysis demonstrated that the existing system provides essential emergency monitoring and response functions but faces several structural limitations, including fragmented data sources, insufficient digital integration, lack of standardized risk assessment procedures and limited multidisciplinary workforce capacity. Based on these findings, the authors developed the Integrated Risk-Oriented Public Health Emergency Operations Model. The proposed model integrates five core components: an early warning system, a risk assessment unit, forecasting and scenario modelling, a multi-level response mechanism (L0-L3), and a digital decision-support platform. A key innovation of the model is the introduction of the “3–8–24-hour risk assessment algorithm”, designed to accelerate threat evaluation and decision-making. Conclusion. Implementation of the IMR framework may strengthen Kazakhstan’s public health emergency preparedness by improving early detection, predictive capacity, intersectoral coordination and evidence-based decision-making. The proposed model provides a conceptual foundation for transforming the national emergency operations center into a proactive risk governance platform aligned with global health security principles.
- Open Access
- 28 October 2026
- Published by National Scientific Center of Traumatology and Orthopaedics named after Academician N.D. Batpenov in Traumatology and Orthopаedics of Kazakhstan
- p. jto067
Participant-Specific Recognition of Grasp Type and Self-Scaled Effort Using Surface Electromyography: A Proof-of-Concept Study for Prosthetic Control in People with Congenital or Acquired Upper-Limb Absence
Objective. To assess participant-specific recognition of grasp type and subjectively scaled effort using surface electromyography in adults without upper-limb amputation, and unintended outputs during ordinary movements. This study is a preliminary step toward prosthetic control for people with congenital or acquired upper-limb absence. Methods. Four adults without upper-limb amputation performed eight command states: rest, open hand, and power grasp and tip pinch at low, medium and high verbally instructed effort. Effort categories were subjective; mechanical force was not measured. A separate linear discriminant analysis model was trained for each participant using time-domain features from consecutive signal windows, followed by causal majority voting over twenty windows. Evaluation comprised held-out trials separated from model fitting, newly recorded command trials processed causally, and ordinary movements without control intent; a confidence threshold of 0.60 was applied retrospectively to the latter. All recordings were obtained during one visit. No physical prosthesis was actuated. Results were summarized descriptively. Results. On held-out trials, mean balanced accuracy was 0.810 for raw windows, 0.823 after majority voting, and 0.875 for trial-level decisions. Among outputs with correctly recognized grasp type, effort recognition was more accurate for power grasp (0.970) than tip pinch (0.706). On newly recorded command trials, mean balanced accuracy was 0.902 and trial accuracy was 0.939; at the confidence threshold, coverage was 0.925 and end-to-end accuracy was 0.862. During ordinary movements, the mean proportion of unintended active outputs was 35.6% and decreased to 22.3% after confidence rejection, which retained 81.3% of outputs. The longest uninterrupted active-output episode after rejection lasted 7.25 seconds. Conclusion. The participant-specific decoder recognized instructed grasp and effort categories under controlled conditions. Unintended outputs during ordinary movements remain a concern for potential prosthetic use. These results do not establish clinical benefit or prosthesis control; evaluation with intended users, physical devices and functional tasks is needed.
- 28 October 2026
- Published by National Scientific Center of Traumatology and Orthopaedics named after Academician N.D. Batpenov in Traumatology and Orthopаedics of Kazakhstan
- p. jto067
Open AccessParticipant-Specific Recognition of Grasp Type and Self-Scaled Effort Using Surface Electromyography: A Proof-of-Concept Study for Prosthetic Control in People with Congenital or Acquired Upper-Limb Absence
Objective. To assess participant-specific recognition of grasp type and subjectively scaled effort using surface electromyography in adults without upper-limb amputation, and unintended outputs during ordinary movements. This study is a preliminary step toward prosthetic control for people with congenital or acquired upper-limb absence. Methods. Four adults without upper-limb amputation performed eight command states: rest, open hand, and power grasp and tip pinch at low, medium and high verbally instructed effort. Effort categories were subjective; mechanical force was not measured. A separate linear discriminant analysis model was trained for each participant using time-domain features from consecutive signal windows, followed by causal majority voting over twenty windows. Evaluation comprised held-out trials separated from model fitting, newly recorded command trials processed causally, and ordinary movements without control intent; a confidence threshold of 0.60 was applied retrospectively to the latter. All recordings were obtained during one visit. No physical prosthesis was actuated. Results were summarized descriptively. Results. On held-out trials, mean balanced accuracy was 0.810 for raw windows, 0.823 after majority voting, and 0.875 for trial-level decisions. Among outputs with correctly recognized grasp type, effort recognition was more accurate for power grasp (0.970) than tip pinch (0.706). On newly recorded command trials, mean balanced accuracy was 0.902 and trial accuracy was 0.939; at the confidence threshold, coverage was 0.925 and end-to-end accuracy was 0.862. During ordinary movements, the mean proportion of unintended active outputs was 35.6% and decreased to 22.3% after confidence rejection, which retained 81.3% of outputs. The longest uninterrupted active-output episode after rejection lasted 7.25 seconds. Conclusion. The participant-specific decoder recognized instructed grasp and effort categories under controlled conditions. Unintended outputs during ordinary movements remain a concern for potential prosthetic use. These results do not establish clinical benefit or prosthesis control; evaluation with intended users, physical devices and functional tasks is needed.