Jie Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Jie Lu has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Feng Liu
Compound Semiconductor Optoelectronics Division, The 44th Research Institute Chongqing China, China
1 shared publication - Jianfeng Sun
National Key Laboratory of Laser Spatial Information, Harbin Institute of Technology, Harbin 150001, China
1 shared publication - Xianhui Yang
Institute of Optics and Electronics, Harbin Institute of Technology, Harbin, China, China
1 shared publication - Xin Zhou
Institute of Optics and Electronics, Harbin Institute of Technology, Harbin, China, China
1 shared publication
Latest Publications
- Open Access
- 3 November 2026
- Published by MDPI AG in Preprints.org
Research on a Bayesian Estimation Image Reconstruction Method for Geiger Mode Avalanche Photodiode Light Detection and Ranging (GM‐APD LiDAR) Based on Spatiotemporal Features of Sequence Data
In scenes with strong background light, three-dimensional LiDAR imaging still faces problems such as incomplete imaging and residual background noise. This paper proposes a Bayesian-estimation image reconstruction method based on sequence data. Sparse range-intensity sequence data are constructed, and the signal probability and average intensity features of the sequence data are fused to build the likelihood term, thereby highlighting the differences between signal and noise. Through spatiotemporal average-intensity gradient analysis, the MRF prior parameters are adaptively estimated, and a spatial-continuity prior with edge-preserving characteristics is constructed. Under the Bayesian maximum a posteriori estimation framework, spatiotemporal feature fusion is transformed into an energy-minimization problem. The iterative conditional modes algorithm is then used to solve the optimal range image with spatial average intensity as a constraint, and morphological filtering is used to remove isolated noise points. With a data volume of 20,000 frames, the recovery ratio of the reconstructed range image in the 730 m scene reached 82.6%. In the 2,000 m long-range scene with an extremely low signal-to-background ratio (SBR), the recovery ratio reached 56.3%, representing a 46.2% improvement over the SPIRAL method, with an RMSE of 1.77 m. Partial reconstruction can also be achieved in low-SBR regions of long-range buildings, improving target completeness under low signal-to-background ratio conditions.
- 3 November 2026
- Published by MDPI AG in Preprints.org
Open AccessResearch on a Bayesian Estimation Image Reconstruction Method for Geiger Mode Avalanche Photodiode Light Detection and Ranging (GM‐APD LiDAR) Based on Spatiotemporal Features of Sequence Data
In scenes with strong background light, three-dimensional LiDAR imaging still faces problems such as incomplete imaging and residual background noise. This paper proposes a Bayesian-estimation image reconstruction method based on sequence data. Sparse range-intensity sequence data are constructed, and the signal probability and average intensity features of the sequence data are fused to build the likelihood term, thereby highlighting the differences between signal and noise. Through spatiotemporal average-intensity gradient analysis, the MRF prior parameters are adaptively estimated, and a spatial-continuity prior with edge-preserving characteristics is constructed. Under the Bayesian maximum a posteriori estimation framework, spatiotemporal feature fusion is transformed into an energy-minimization problem. The iterative conditional modes algorithm is then used to solve the optimal range image with spatial average intensity as a constraint, and morphological filtering is used to remove isolated noise points. With a data volume of 20,000 frames, the recovery ratio of the reconstructed range image in the 730 m scene reached 82.6%. In the 2,000 m long-range scene with an extremely low signal-to-background ratio (SBR), the recovery ratio reached 56.3%, representing a 46.2% improvement over the SPIRAL method, with an RMSE of 1.77 m. Partial reconstruction can also be achieved in low-SBR regions of long-range buildings, improving target completeness under low signal-to-background ratio conditions.