Lian Tu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lian Tu has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Jianxin Zhang
Dispatching Control Center, China Southern Power Grid, Guangzhou 501699, China
1 shared publication - Jinchang Chen
Electric Power Dispatching and Control Center of Guangdong Power Grid Co., Ltd., Guangzhou 510000, China
1 shared publication - Qi Wang
School of Electrical Engineering, Southeast University, Nanjing, China
1 shared publication - Shiyang Li
China Southern Power Grid Research Institute Co., Ltd., Guangzhou 510663, China
1 shared publication - Wei Tai
School of Cyber Science and Engineering, Southeast University, Nanjing 210000, China
1 shared publication
Latest Publications
- Open Access
Trustworthiness Viability of Closed-Loop Online Power-System Defense Under Evidence and Response-Time Constraints
Online power-system defense increasingly depends on automated assessment, strategy generation, and real-time implementation. However, the accuracy of a single model or controller does not establish the trustworthiness of the complete closed loop. This paper proposes a mission-level framework for closed-loop trustworthiness under physical, informational, and temporal uncertainty. Trustworthiness is defined as the lowest finite-horizon mission-success probability over all probability laws consistent with available evidence. The resulting trustworthiness viability domain contains the joint physical, evidence, dependence, and response-time states from which a required trustworthiness level remains achievable. A recursive characterization supports model-conditional certification and boundary warning. Additional evidence can reduce maintainable trustworthiness when its acquisition delay removes feasible recovery actions. Safe abnormality identifiability requires diagnostic actions to remain inside the viability domain, while a counterfactual deficit measure locates abnormalities with the largest mission-level effect. Conditions are also derived for heterogeneous redundancy and certified fallback. On a modified Reliability Test System–Grid Modernization Lab Consortium (RTS-GMLC) system, 14.3% of test states were physically secure but were not certified at the required trustworthiness level. Under the scenario-based model, 94.6% of abnormal cases met the 0.95 trustworthiness threshold with runtime selection. Texas2k tests quantified the accuracy–runtime tradeoff at a larger network scale.
Open AccessTrustworthiness Viability of Closed-Loop Online Power-System Defense Under Evidence and Response-Time Constraints
Online power-system defense increasingly depends on automated assessment, strategy generation, and real-time implementation. However, the accuracy of a single model or controller does not establish the trustworthiness of the complete closed loop. This paper proposes a mission-level framework for closed-loop trustworthiness under physical, informational, and temporal uncertainty. Trustworthiness is defined as the lowest finite-horizon mission-success probability over all probability laws consistent with available evidence. The resulting trustworthiness viability domain contains the joint physical, evidence, dependence, and response-time states from which a required trustworthiness level remains achievable. A recursive characterization supports model-conditional certification and boundary warning. Additional evidence can reduce maintainable trustworthiness when its acquisition delay removes feasible recovery actions. Safe abnormality identifiability requires diagnostic actions to remain inside the viability domain, while a counterfactual deficit measure locates abnormalities with the largest mission-level effect. Conditions are also derived for heterogeneous redundancy and certified fallback. On a modified Reliability Test System–Grid Modernization Lab Consortium (RTS-GMLC) system, 14.3% of test states were physically secure but were not certified at the required trustworthiness level. Under the scenario-based model, 94.6% of abnormal cases met the 0.95 trustworthiness threshold with runtime selection. Texas2k tests quantified the accuracy–runtime tradeoff at a larger network scale.