Kevin Jacob Willy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kevin Jacob Willy has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- David J. Gladstone
Dartmouth College
2 shared publications - Aleksandra Ilina
Dartmouth College
1 shared publication Brian W Pogue
Dartmouth College
1 shared publication- Corbin Narita
Dartmouth College Thayer School of Engineering
1 shared publication David I Hunter
Dartmouth College
1 shared publicationJason R Gunn
Dartmouth College
1 shared publication
Latest Publications
- Open Access
- 19 November 2026
- Published by IOP Publishing in Physics in Medicine & Biology
Multi-beam FLASH-RT preserves skin sparing and reveals novel tissue oxygen dynamics in a murine model
Objective. The goal of this project was to investigate whether the FLASH skin-sparing effect is preserved across multi-beam ultra-high-dose-rate (UHDR) deliveries and to characterize the accompanying in vivo tissue oxygen dynamics near a 5-second total treatment window previously shown to maintain sparing. Approach. Mice were irradiated at three dose levels (23.6, 25.2, and 25.9 Gy) across five experimental groups: single-beam UHDR, two-beam UHDR, six beam UHDR, twelve-beam UHDR, and conventional dose rate (CDR). To evaluate normal tissue toxicity, a skin damage cohort was monitored photographically for four weeks post-irradiation, with acute reactions evaluated by a trained observer. In a separate cohort, real-time tissue oxygenation (pO2) was tracked via a fiber-optic phosphorometer using the phosphorescent probe Oxyphor PtG4 to evaluate physiological kinetics independently of the longitudinal toxicity study. Main results. The FLASH skin-sparing effect was statistically indistinguishable for all experimentally tested UHDR configurations at the 23.6 Gy and 25.2 Gy dose levels. Mixed-effects regression analysis demonstrated that all four UHDR groups developed significantly lower skin toxicity scores compared to the CDR group (p < 0.05). At the highest dose level (25.9 Gy), no significant differences were observed among any radiation groups, which was attributed to a saturation effect of the visual skin score assay at severe damage thresholds. In vivo oximetry showed that tissue oxygen resupply accelerated during UHDR treatment, driven by localized concentration gradients and amplified post-RT by acute biological mechanisms. Significance. This study represents a promising step toward UHDR multi-beam delivery, a prerequisite for clinical conformal treatment planning. Multiple UHDR beams delivered within five seconds provide a statistically indistinguishable degree of normal tissue sparing as a single UHDR beam. Furthermore, the observed tissue oxygen dynamics reveal an acute biological response potentially unique to UHDR delivery, shedding light on a novel physiological component of the FLASH mechanism.
- 19 November 2026
- Published by IOP Publishing in Physics in Medicine & Biology
Open AccessMulti-beam FLASH-RT preserves skin sparing and reveals novel tissue oxygen dynamics in a murine model
Objective. The goal of this project was to investigate whether the FLASH skin-sparing effect is preserved across multi-beam ultra-high-dose-rate (UHDR) deliveries and to characterize the accompanying in vivo tissue oxygen dynamics near a 5-second total treatment window previously shown to maintain sparing. Approach. Mice were irradiated at three dose levels (23.6, 25.2, and 25.9 Gy) across five experimental groups: single-beam UHDR, two-beam UHDR, six beam UHDR, twelve-beam UHDR, and conventional dose rate (CDR). To evaluate normal tissue toxicity, a skin damage cohort was monitored photographically for four weeks post-irradiation, with acute reactions evaluated by a trained observer. In a separate cohort, real-time tissue oxygenation (pO2) was tracked via a fiber-optic phosphorometer using the phosphorescent probe Oxyphor PtG4 to evaluate physiological kinetics independently of the longitudinal toxicity study. Main results. The FLASH skin-sparing effect was statistically indistinguishable for all experimentally tested UHDR configurations at the 23.6 Gy and 25.2 Gy dose levels. Mixed-effects regression analysis demonstrated that all four UHDR groups developed significantly lower skin toxicity scores compared to the CDR group (p < 0.05). At the highest dose level (25.9 Gy), no significant differences were observed among any radiation groups, which was attributed to a saturation effect of the visual skin score assay at severe damage thresholds. In vivo oximetry showed that tissue oxygen resupply accelerated during UHDR treatment, driven by localized concentration gradients and amplified post-RT by acute biological mechanisms. Significance. This study represents a promising step toward UHDR multi-beam delivery, a prerequisite for clinical conformal treatment planning. Multiple UHDR beams delivered within five seconds provide a statistically indistinguishable degree of normal tissue sparing as a single UHDR beam. Furthermore, the observed tissue oxygen dynamics reveal an acute biological response potentially unique to UHDR delivery, shedding light on a novel physiological component of the FLASH mechanism.
- Open Access
- 6 November 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (22) , 225009
Pulse-width-specific phase space modeling and reference beam characterization for UHDR electron LINAC in FLASH-RT
Objective: FLASH radiotherapy requires ultra-high dose rates (>40 Gy/s), yet commercial treatment planning systems are currently unavailable. Monte Carlo (MC) simulation offers high transport accuracy, but full-head modeling for every setup is computationally prohibitive. This work establishes a methodology for generating pulse-width-specific phase-space files for the Mobetron UHDR (9 MeV), accounting for systematic beam quality shifts caused by RF waveguide loading across pulse widths of 1.2-4.0 μs. Approach: Using GAMOS 6.2.0 MC simulations, voxelized dose distributions were post-processed via an iterative script to refine source-level parameters against experimental targets. Mean energy was optimized by matching phantom-measured R50, while energy spread was refined using surface dose and build-up gradients. Relationships derived from a mid-range 6 cm applicator were applied across clinical apertures (2.5-10 cm) to test aperture-independence. The geometric mean of experimental pulse widths (2.28 μs) was evaluated as a single reference condition. Main Results: Phase space files were generated across pulse widths and apertures. For the A6I6 reference, mean energy decreased monotonically from 9.58±0.24 to 9.04±0.24 MeV with pulse width, best described by a logarithmic model (LOO-RMSE=0.033 MeV). Energy spread increased linearly from 0.173±0.020 to 0.287±0.020 MeV (LOO-RMSE=0.005 MeV). Cross-aperture validation confirmed these shifts occur upstream of collimation. Evaluating the 2.28 μs reference predicted 9.30 MeV mean energy and 0.215 MeV energy spread, yielding depth-dose deviations ≤1.3 mm across experimental extremes and satisfying AAPM TG-106 tolerances (≤2.0 mm). Significance: This work provides pulse-width-specific phase-space characterization for Mobetron FLASH commissioning. Cross-validated regression models enable beam parameter prediction within 1.2-4.0 μs, and the 2.28 μs reference phase space streamlines routine planning while maintaining clinical accuracy.
- 6 November 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (22) , 225009
Open AccessPulse-width-specific phase space modeling and reference beam characterization for UHDR electron LINAC in FLASH-RT
Objective: FLASH radiotherapy requires ultra-high dose rates (>40 Gy/s), yet commercial treatment planning systems are currently unavailable. Monte Carlo (MC) simulation offers high transport accuracy, but full-head modeling for every setup is computationally prohibitive. This work establishes a methodology for generating pulse-width-specific phase-space files for the Mobetron UHDR (9 MeV), accounting for systematic beam quality shifts caused by RF waveguide loading across pulse widths of 1.2-4.0 μs. Approach: Using GAMOS 6.2.0 MC simulations, voxelized dose distributions were post-processed via an iterative script to refine source-level parameters against experimental targets. Mean energy was optimized by matching phantom-measured R50, while energy spread was refined using surface dose and build-up gradients. Relationships derived from a mid-range 6 cm applicator were applied across clinical apertures (2.5-10 cm) to test aperture-independence. The geometric mean of experimental pulse widths (2.28 μs) was evaluated as a single reference condition. Main Results: Phase space files were generated across pulse widths and apertures. For the A6I6 reference, mean energy decreased monotonically from 9.58±0.24 to 9.04±0.24 MeV with pulse width, best described by a logarithmic model (LOO-RMSE=0.033 MeV). Energy spread increased linearly from 0.173±0.020 to 0.287±0.020 MeV (LOO-RMSE=0.005 MeV). Cross-aperture validation confirmed these shifts occur upstream of collimation. Evaluating the 2.28 μs reference predicted 9.30 MeV mean energy and 0.215 MeV energy spread, yielding depth-dose deviations ≤1.3 mm across experimental extremes and satisfying AAPM TG-106 tolerances (≤2.0 mm). Significance: This work provides pulse-width-specific phase-space characterization for Mobetron FLASH commissioning. Cross-validated regression models enable beam parameter prediction within 1.2-4.0 μs, and the 2.28 μs reference phase space streamlines routine planning while maintaining clinical accuracy.