Jordan Squair
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jordan Squair has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Alessandro Pesaresi
Neurosurgery Unit, University of Turin, A.O.U. Città della Salute e della Scienza, Turin, Italy
1 shared publication - Amine Mellal
Department of Neurosurgery, Lausanne University Hospital, Lausanne, Switzerland
1 shared publication - Daniele Starnoni
Department of Clinical Neurosciences, Neurosurgery Service and Gamma Knife Center, Centre Hospitalier Universitaire Vaudois (CHUV), Lausanne, Switzerland
1 shared publication - Diego Garbossa
Neurosurgery Unit, Department of Neuroscience “Rita Levi-Montalcini”, University of Turin, Turin, Italy
1 shared publication - Fumihiro Matano
Department of Neurological Surgery, Nippon Medical School, Tokyo, Japan
1 shared publication - Giulia Cossu
Department of Neurosurgery, University Hospital of Lausanne and University of Lausanne, Lausanne, Switzerland
1 shared publication
Latest Publications
- Open Access
- 11 November 2026
- Published by Wolters Kluwer Health in Operative Neurosurgery
Anatomic and Ergonomic Impact of C1 Transversectomy on the Anterolateral OA–V3 Bypass Corridor: A Cadaveric Study
BACKGROUND AND OBJECTIVES: The occipital artery–vertebral artery (OA–VA) bypass of the V3 segment has been described as a possible feasible revascularization strategy through the anterolateral approach. However, the impact of C1 transverse process removal on surgical corridor expansion, VA mobility, and microsurgical ergonomics has not been evaluated. In this cadaveric study, we assessed the anatomic and ergonomic effect of C1 transversectomy for OA–V3 bypass. METHODS: Five injected cadaveric specimens (10 sides) were subjected to paired analysis comparing standard anterolateral exposure (baseline) vs the same approach with C1 transversectomy and VA skeletonization. Quantitative end points included surgical working area, exposed VA length, working depth, and instrument divergence angle. Paired statistical analysis was calculated. RESULTS: C1 transversectomy resulted in a significant improvement in all major parameters of surgical exposure. The working area increased by 130% (from 226.1 to 519.1 mm 2 , P < .001), whereas the exposed VA length increased by 84% (from 12.7 to 23.4 mm, P = .002). VA mobility demonstrated the greatest relative gain, increasing by 207% (from 1.5 to 4.6 mm, P < .001). The instrument divergence angle also significantly improved, increasing by 109% (from 18.2° to 38.1°, P < .001). No statistically significant changes were observed in working depth. CONCLUSION: C1 transversectomy markedly enhances exposure, mobility, and operative ergonomics within the anterolateral OA–V3 corridor. These findings provide quantitative anatomic validation of a technical refinement that may improve reproducibility and safety of OA–VA bypass in selected clinical scenarios.
- 11 November 2026
- Published by Wolters Kluwer Health in Operative Neurosurgery
Open AccessAnatomic and Ergonomic Impact of C1 Transversectomy on the Anterolateral OA–V3 Bypass Corridor: A Cadaveric Study
BACKGROUND AND OBJECTIVES: The occipital artery–vertebral artery (OA–VA) bypass of the V3 segment has been described as a possible feasible revascularization strategy through the anterolateral approach. However, the impact of C1 transverse process removal on surgical corridor expansion, VA mobility, and microsurgical ergonomics has not been evaluated. In this cadaveric study, we assessed the anatomic and ergonomic effect of C1 transversectomy for OA–V3 bypass. METHODS: Five injected cadaveric specimens (10 sides) were subjected to paired analysis comparing standard anterolateral exposure (baseline) vs the same approach with C1 transversectomy and VA skeletonization. Quantitative end points included surgical working area, exposed VA length, working depth, and instrument divergence angle. Paired statistical analysis was calculated. RESULTS: C1 transversectomy resulted in a significant improvement in all major parameters of surgical exposure. The working area increased by 130% (from 226.1 to 519.1 mm 2 , P < .001), whereas the exposed VA length increased by 84% (from 12.7 to 23.4 mm, P = .002). VA mobility demonstrated the greatest relative gain, increasing by 207% (from 1.5 to 4.6 mm, P < .001). The instrument divergence angle also significantly improved, increasing by 109% (from 18.2° to 38.1°, P < .001). No statistically significant changes were observed in working depth. CONCLUSION: C1 transversectomy markedly enhances exposure, mobility, and operative ergonomics within the anterolateral OA–V3 corridor. These findings provide quantitative anatomic validation of a technical refinement that may improve reproducibility and safety of OA–VA bypass in selected clinical scenarios.