David Borozenets
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
David Borozenets has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Farida Amenova
Higher School of Information Technology and Natural Sciences, Sarsen Amanzholov East Kazakhstan University, Ust-Kamenogorsk, Kazakhstan, Kazakhstan
1 shared publication - Karlygash Alibekkyzy
School of Information Technologies and Intelligent Systems, D. Serikbayev East Kazakhstan State Technical University, Ust-Kamenogorsk, Kazakhstan, Kazakhstan
1 shared publication - Madina Bazarova
Department of Information Technology and Natural Sciences, Sarsen Amanzholov East Kazakhstan University
1 shared publication - Saule Belginova
Higher School of Information Technology, Turan University, Almaty, Kazakhstan, Kazakhstan
1 shared publication - Talshyn Keribayeva
Department “Aviation Equipment and Technologies”, Academy of Civil Aviation, Almaty, Kazakhstan, Kazakhstan
1 shared publication - Ж.т. Рахметуллина
International Engineering School, D. Serikbayev East Kazakhstan State Technical University, Ust-Kamenogorsk, Kazakhstan, Kazakhstan
1 shared publication
Latest Publications
- Open Access
- 13 November 2026
- Published by MDPI AG in Preprints.org
Design and Technical Validation of an Acid–Base Balance Analysis Module in the Gasometry Web-Based Information System
Reliable clinical information systems require not only correct numerical calculations but also robust input validation, consistent decision logic, and reproducible performance. This study evaluated the Acid–Base Balance Analysis module of Gasometry, a React/TypeScript web platform, using source-code inspection and browser-based testing of a local production build. A set of 160 synthetic scenarios comprised 120 numerical and 40 technical-input cases; additional experiments assessed 300 repeated executions, 20 cross-browser scenario pairs, and 480 load-test operations. The implemented potassium-inclusive anion-gap expression agreed with an independent decimal-arithmetic reference in all 120 numerical cases within 0.01 mmol/L, while decision-branch concordance was 119/120. However, none of 33 invalid inputs met the predefined strict rejection criterion, and varying pH and pCO₂ did not change terminal outcomes when electrolytes were held constant, revealing a control-flow defect. All 300 repeat executions were consistent, and 19/20 cross-browser pairs matched. Median and 95th-percentile interface-transition times were 1.60 and 2.40 ms, respectively. These findings demonstrate numerical reproducibility but identify input-validation and interpretation-logic weaknesses. The results constitute technical rather than clinical validation; software corrections and clinician-reviewed testing are required before clinical deployment.
- 13 November 2026
- Published by MDPI AG in Preprints.org
Open AccessDesign and Technical Validation of an Acid–Base Balance Analysis Module in the Gasometry Web-Based Information System
Reliable clinical information systems require not only correct numerical calculations but also robust input validation, consistent decision logic, and reproducible performance. This study evaluated the Acid–Base Balance Analysis module of Gasometry, a React/TypeScript web platform, using source-code inspection and browser-based testing of a local production build. A set of 160 synthetic scenarios comprised 120 numerical and 40 technical-input cases; additional experiments assessed 300 repeated executions, 20 cross-browser scenario pairs, and 480 load-test operations. The implemented potassium-inclusive anion-gap expression agreed with an independent decimal-arithmetic reference in all 120 numerical cases within 0.01 mmol/L, while decision-branch concordance was 119/120. However, none of 33 invalid inputs met the predefined strict rejection criterion, and varying pH and pCO₂ did not change terminal outcomes when electrolytes were held constant, revealing a control-flow defect. All 300 repeat executions were consistent, and 19/20 cross-browser pairs matched. Median and 95th-percentile interface-transition times were 1.60 and 2.40 ms, respectively. These findings demonstrate numerical reproducibility but identify input-validation and interpretation-logic weaknesses. The results constitute technical rather than clinical validation; software corrections and clinician-reviewed testing are required before clinical deployment.