Da-Gyeong Shin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Da-Gyeong Shin has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Byung-Dong Hahn
Nano Materials Research Division, Korea Institute of Materials Science (KIMS), Changwon 51508, Republic of Korea
1 shared publication - Cheol-Woo Ahn
Nano Materials Research Division, Korea Institute of Materials Science (KIMS), Changwon 51508, Republic of Korea
1 shared publication - Hyun-Ae Cha
Nano Materials Research Division, Korea Institute of Materials Science (KIMS), Changwon 51508, Republic of Korea
1 shared publication - Jong-Jin Choi
Korea Institute of Materials Science (KIMS), Changwon 51508, Korea
1 shared publication - Jung Woo Lee
Department of Materials Science and Engineering Pusan National University Busan Republic of Korea
1 shared publication - Ki Beom Kim
Department of Materials Science and Engineering, Korea University, Seoul 02841, Republic of Korea
1 shared publication
Latest Publications
- Open Access
Selective ppb-Level NO Detection Under High-Humidity Conditions Using Trace Pt-Functionalized WO3 Gas Sensors
Direct and selective detection of nitric oxide (NO) in exhaled breath is essential for non-invasive asthma assessment, but remains challenging because of its low concentration, high humidity, and the presence of interfering gases. Herein, WO3 nanoparticles functionalized with trace amounts of Pt (0.05–0.3 at%) were prepared for selective ppb-level NO detection. The effects of Pt loading and sensing temperature on the gas-sensing characteristics were systematically investigated using 25 ppb NO and representative breath interferents at their typical concentrations in exhaled breath (0.5 ppm acetone, 1 ppm ethanol, 5 ppm CO, 20 ppm H2, and 0.1 ppm H2S) in a highly humid atmosphere (RH 80%). The 0.1 at% Pt-loaded WO3 sensor exhibited a relatively high response (S = 3.0) and selectivity (SNO/SH2S = 4.8) to 25 ppb NO at a low sensing temperature of 100 °C, together with a low detection limit of 0.14 ppb and stable sensing performance for 15 days. Notably, precise control of Pt loading was critical for enhancing NO sensitivity while suppressing responses to interfering gases. The sensing behavior was further analyzed in terms of receptor, transducer, and utility functions, providing insights into the bell-shaped temperature dependence of the NO response and the distinct optimal sensing temperatures of NO and interfering H2S. These findings highlight trace noble-metal functionalization as an effective strategy for achieving selective NO detection under humid conditions and provide a promising foundation for developing chemiresistive breath sensors for asthma diagnosis.
Open AccessSelective ppb-Level NO Detection Under High-Humidity Conditions Using Trace Pt-Functionalized WO3 Gas Sensors
Direct and selective detection of nitric oxide (NO) in exhaled breath is essential for non-invasive asthma assessment, but remains challenging because of its low concentration, high humidity, and the presence of interfering gases. Herein, WO3 nanoparticles functionalized with trace amounts of Pt (0.05–0.3 at%) were prepared for selective ppb-level NO detection. The effects of Pt loading and sensing temperature on the gas-sensing characteristics were systematically investigated using 25 ppb NO and representative breath interferents at their typical concentrations in exhaled breath (0.5 ppm acetone, 1 ppm ethanol, 5 ppm CO, 20 ppm H2, and 0.1 ppm H2S) in a highly humid atmosphere (RH 80%). The 0.1 at% Pt-loaded WO3 sensor exhibited a relatively high response (S = 3.0) and selectivity (SNO/SH2S = 4.8) to 25 ppb NO at a low sensing temperature of 100 °C, together with a low detection limit of 0.14 ppb and stable sensing performance for 15 days. Notably, precise control of Pt loading was critical for enhancing NO sensitivity while suppressing responses to interfering gases. The sensing behavior was further analyzed in terms of receptor, transducer, and utility functions, providing insights into the bell-shaped temperature dependence of the NO response and the distinct optimal sensing temperatures of NO and interfering H2S. These findings highlight trace noble-metal functionalization as an effective strategy for achieving selective NO detection under humid conditions and provide a promising foundation for developing chemiresistive breath sensors for asthma diagnosis.