Orpan Taluckder Uthsha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Orpan Taluckder Uthsha has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Kata Sreelakshmi
Sri Padmavati Mahila Visvavidyalayam
1 shared publication - Mahbubur Rahman
Department of Mechanical Engineering, Khulna University of Engineering & Technology, Khulna 9203, Bangladesh
1 shared publication - Md. Shah Najmus Shakib
Department of Mathematics University of Barishal Barishal Bangladesh bu.ac.bd
1 shared publication - Mohammad Monjurul Ehsan
Department of Mechanical and Production Engineering (MPE), Islamic University of Technology (IUT), Board Bazaar, Gazipur 1704, Bangladesh
1 shared publication - Raza Moshwan
Materials Engineering, The University of Queensland, Brisbane, Australia
1 shared publication - Saiful Islam
Department of Mechanical Engineering Khulna University of Engineering and Technology Khulna Bangladesh kuet.ac.bd
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by Wiley in Journal of Engineering
- Vol. 2026 (1)
Numerical Investigation of Trihybrid Nanofluid Flow in Different Tube Geometries for Enhanced Thermal Management
Efficient thermal management is essential for high‐performance electronic and energy systems. This study numerically investigates the thermal‐hydraulic performance of Al 2 O 3 –Cu–MWCNT/water–ethylene glycol (60:40) trihybrid nanofluid (THNF) in smooth, internally finned, and externally finned pipes. Computational fluid dynamics (CFD) simulations were performed at Reynolds numbers of 8000–16,000 and nanoparticle volume fractions of 1%–3%, under a uniform heat flux of 8957 W/m 2 . The study systematically evaluates the combined effects of nanoparticle concentration and fin arrangement under identical operating conditions. At Re = 16,000, the internally finned pipe achieved heat transfer enhancements of 14.58% for water–EG (60:40) and 12.34% for 3% THNF compared with the smooth pipe. Increasing nanoparticle concentration improved the heat transfer coefficient, reaching a maximum of 5458.55 W/m 2 ·K for 3% THNF in the internally finned pipe at Re = 16,000. However, increased frictional resistance reduced its overall thermal‐hydraulic efficiency. The externally finned pipe with water–EG achieved the highest performance evaluation criterion (PEC), with a maximum improvement of 3.38% at Re = 16,000, compared with 2.08% for 3% THNF at Re = 16,000. Thus, the externally finned pipe with water–EG provides the best thermal‐hydraulic balance among the investigated configurations.
- 1 January 2026
- Published by Wiley in Journal of Engineering
- Vol. 2026 (1)
Open AccessNumerical Investigation of Trihybrid Nanofluid Flow in Different Tube Geometries for Enhanced Thermal Management
Efficient thermal management is essential for high‐performance electronic and energy systems. This study numerically investigates the thermal‐hydraulic performance of Al 2 O 3 –Cu–MWCNT/water–ethylene glycol (60:40) trihybrid nanofluid (THNF) in smooth, internally finned, and externally finned pipes. Computational fluid dynamics (CFD) simulations were performed at Reynolds numbers of 8000–16,000 and nanoparticle volume fractions of 1%–3%, under a uniform heat flux of 8957 W/m 2 . The study systematically evaluates the combined effects of nanoparticle concentration and fin arrangement under identical operating conditions. At Re = 16,000, the internally finned pipe achieved heat transfer enhancements of 14.58% for water–EG (60:40) and 12.34% for 3% THNF compared with the smooth pipe. Increasing nanoparticle concentration improved the heat transfer coefficient, reaching a maximum of 5458.55 W/m 2 ·K for 3% THNF in the internally finned pipe at Re = 16,000. However, increased frictional resistance reduced its overall thermal‐hydraulic efficiency. The externally finned pipe with water–EG achieved the highest performance evaluation criterion (PEC), with a maximum improvement of 3.38% at Re = 16,000, compared with 2.08% for 3% THNF at Re = 16,000. Thus, the externally finned pipe with water–EG provides the best thermal‐hydraulic balance among the investigated configurations.