Fabián Gómez-Santiago
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Fabián Gómez-Santiago has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Angelina Aguilar-Guzmán
Instituto de Diagnóstico y Referencia Epidemiológicos, Secretaría de Salud, Francisco de P Miranda 177, Lomas de Plateros, Álvaro Obregón, Mexico City 01480, Mexico
1 shared publication - Atenea Estela Andrés-Dionicio
Instituto de Diagnóstico y Referencia Epidemiológicos, Secretaría de Salud, Francisco de P Miranda 177, Lomas de Plateros, Álvaro Obregón, Mexico City 01480, Mexico
1 shared publication - David Esaú Fragoso-Fonseca
Instituto de Diagnóstico y Referencia Epidemiológicos, Secretaría de Salud, Francisco de P Miranda 177, Lomas de Plateros, Álvaro Obregón, Mexico City 01480, Mexico
1 shared publication - Gerardo Andrés Tapia-Flores
Instituto de Diagnóstico y Referencia Epidemiológicos, Secretaría de Salud, Francisco de P Miranda 177, Lomas de Plateros, Álvaro Obregón, Mexico City 01480, Mexico
1 shared publication - Heidi Lizbeth Terán-Vega
Instituto de Diagnóstico y Referencia Epidemiológicos, Secretaría de Salud, Francisco de P Miranda 177, Lomas de Plateros, Álvaro Obregón, Mexico City 01480, Mexico
1 shared publication - Herlinda García-Lozano
Instituto de Diagnóstico y Referencia Epidemiológicos, Secretaría de Salud, Francisco de P Miranda 177, Lomas de Plateros, Álvaro Obregón, Mexico City 01480, Mexico
1 shared publication
Latest Publications
- Open Access
- 16 November 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (22) , 3804
Analytical Comparison of Two Real-Time RT-PCR Assays and Development of an External Positive Control for Rotavirus A Laboratory Surveillance in Mexico
Background: Rotavirus A causes diarrhea mainly in children under the age of five. Diarrhea is often nonspecific, so rotavirus detection is necessary to provide appropriate clinical care. Real-time reverse transcription-polymerase chain reaction (RT-PCR) is a sensitive, specific method that provides rapid, reliable results. Methods: Two real-time RT-PCR protocols targeting the highly conserved region of the NSP3 gene and widely used for rotavirus A detection were compared based on their analytical verification parameters. An in-house external positive control (consisting of plasmid DNA containing the viral NSP3 gene) was employed throughout the analytical verification of both real-time RT-PCR assays. Results: Reactivity results were consistent across both real-time RT-PCR protocols, showing repeatable and reproducible Ct values, with no statistically significant differences observed in the precision assays (repeatability: ∝ = 0.05, t = −1.6903, p = 0.1218; reproducibility: ∝ = 0.05, t = −1.1246, p = 0.2870). Both real-time RT-PCR protocols also detected between 14.89 and 21.65 copies of the NSP3 gene per reaction. Conclusions: These findings demonstrate equivalent performance of both assays for rotavirus A detection. Therefore, they represent robust and suitable options for technology transfer to National Public Health Laboratories, supporting efforts to strengthen rotavirus surveillance in Mexico.
- 16 November 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (22) , 3804
Open AccessAnalytical Comparison of Two Real-Time RT-PCR Assays and Development of an External Positive Control for Rotavirus A Laboratory Surveillance in Mexico
Background: Rotavirus A causes diarrhea mainly in children under the age of five. Diarrhea is often nonspecific, so rotavirus detection is necessary to provide appropriate clinical care. Real-time reverse transcription-polymerase chain reaction (RT-PCR) is a sensitive, specific method that provides rapid, reliable results. Methods: Two real-time RT-PCR protocols targeting the highly conserved region of the NSP3 gene and widely used for rotavirus A detection were compared based on their analytical verification parameters. An in-house external positive control (consisting of plasmid DNA containing the viral NSP3 gene) was employed throughout the analytical verification of both real-time RT-PCR assays. Results: Reactivity results were consistent across both real-time RT-PCR protocols, showing repeatable and reproducible Ct values, with no statistically significant differences observed in the precision assays (repeatability: ∝ = 0.05, t = −1.6903, p = 0.1218; reproducibility: ∝ = 0.05, t = −1.1246, p = 0.2870). Both real-time RT-PCR protocols also detected between 14.89 and 21.65 copies of the NSP3 gene per reaction. Conclusions: These findings demonstrate equivalent performance of both assays for rotavirus A detection. Therefore, they represent robust and suitable options for technology transfer to National Public Health Laboratories, supporting efforts to strengthen rotavirus surveillance in Mexico.