NANurol Efe Alptekin

Nurol Efe Alptekin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nurol Efe Alptekin has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Artificial Intelligence-Based Lower-Limb Alignment Measurement in Pediatric and Adult Patients: Clinical Validation of Automated and Physician-Supervised Workflows

    by Oğuzhan Günbatar, İsmail Tarık Atasoy, Cengiz Şen, Alper Şükrü Kendirci, Nurol Efe Alptekin, Yavuz Sağlam, Halil İbrahim Balcı

    Background/Objectives: Standing full-length radiographs support pediatric lower-limb deformity assessment and preoperative evaluation. Manual alignment measurement is time-consuming and observer-dependent. We evaluated an author-developed artificial intelligence (AI) system that provides automated measurements and reviewable anatomical landmarks. Methods: This single-center retrospective study used 240 training, 80 validation, and 80 independent test radiographs, partitioned by patient. The test cohort included 80 patients (22 pediatric) and 160 limbs (44 pediatric). Six alignment angles were assessed against the mean of three measurements by an experienced deformity surgeon. Fully automated AI, unassisted physician workflows, and an AI-assisted resident workflow were compared using intraclass correlation coefficients (ICCs), mean absolute error (MAE), Bland–Altman analysis, and measurement time. Results: Fully automated AI achieved ICCs of 0.728–0.966 and MAEs of 0.52–1.26° across the six angles. In pediatric limbs, average-measure ICCs were 0.936–0.975 for five major alignment angles; the single-measure ICC for joint line convergence angle was 0.825. For the resident evaluated, AI-assisted MAEs were 0.57–1.41°, compared with 1.22–6.83° without assistance. Mean measurement time per radiograph was 2.7 ± 0.4 s for fully automated AI and 10.5 ± 3.4 s for physician-reviewed AI, compared with 77.9–100.5 s for unassisted physician workflows. Conclusions: The AI system provided angle-specific agreement with the expert reference and substantially faster measurement than unassisted workflows. Physician-supervised AI was associated with lower measurement error for the resident evaluated. The findings suggest potential utility as a physician-reviewed measurement aid. Pediatric results are encouraging and should be interpreted as descriptive evidence within the evaluated age range.