Nurol Efe Alptekin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nurol Efe Alptekin has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Alper Şükrü Kendirci
Istanbul University, Istanbul Faculty of Medicine, Department of Orthopedics and Traumatology, Istanbul, Turkey
1 shared publication - Cengiz Şen
Department of Orthopedics and Traumatology, Istanbul Faculty of Medicine, Istanbul University, Istanbul 34093, Türkiye
1 shared publication - Halil İbrahim Balcı
Department of Orthopaedics and Traumatology, Istanbul University, Istanbul School of Medicine, Istanbul, Turkey
1 shared publication - Oğuzhan Günbatar
Department of Orthopedics and Traumatology, Istanbul Faculty of Medicine, Istanbul University, Istanbul 34093, Türkiye
1 shared publication - Yavuz Sağlam
Department of Orthopedics and Traumatology, Istanbul Faculty of Medicine, Istanbul University, Istanbul 34093, Türkiye
1 shared publication - İsmail Tarık Atasoy
Department of Orthopedics and Traumatology, Istanbul Faculty of Medicine, Istanbul University, Istanbul 34093, Türkiye
1 shared publication
Latest Publications
- Open Access
Artificial Intelligence-Based Lower-Limb Alignment Measurement in Pediatric and Adult Patients: Clinical Validation of Automated and Physician-Supervised Workflows
Background/Objectives: Standing full-length radiographs support pediatric lower-limb deformity assessment and preoperative evaluation. Manual alignment measurement is time-consuming and observer-dependent. We evaluated an author-developed artificial intelligence (AI) system that provides automated measurements and reviewable anatomical landmarks. Methods: This single-center retrospective study used 240 training, 80 validation, and 80 independent test radiographs, partitioned by patient. The test cohort included 80 patients (22 pediatric) and 160 limbs (44 pediatric). Six alignment angles were assessed against the mean of three measurements by an experienced deformity surgeon. Fully automated AI, unassisted physician workflows, and an AI-assisted resident workflow were compared using intraclass correlation coefficients (ICCs), mean absolute error (MAE), Bland–Altman analysis, and measurement time. Results: Fully automated AI achieved ICCs of 0.728–0.966 and MAEs of 0.52–1.26° across the six angles. In pediatric limbs, average-measure ICCs were 0.936–0.975 for five major alignment angles; the single-measure ICC for joint line convergence angle was 0.825. For the resident evaluated, AI-assisted MAEs were 0.57–1.41°, compared with 1.22–6.83° without assistance. Mean measurement time per radiograph was 2.7 ± 0.4 s for fully automated AI and 10.5 ± 3.4 s for physician-reviewed AI, compared with 77.9–100.5 s for unassisted physician workflows. Conclusions: The AI system provided angle-specific agreement with the expert reference and substantially faster measurement than unassisted workflows. Physician-supervised AI was associated with lower measurement error for the resident evaluated. The findings suggest potential utility as a physician-reviewed measurement aid. Pediatric results are encouraging and should be interpreted as descriptive evidence within the evaluated age range.
Open AccessArtificial Intelligence-Based Lower-Limb Alignment Measurement in Pediatric and Adult Patients: Clinical Validation of Automated and Physician-Supervised Workflows
Background/Objectives: Standing full-length radiographs support pediatric lower-limb deformity assessment and preoperative evaluation. Manual alignment measurement is time-consuming and observer-dependent. We evaluated an author-developed artificial intelligence (AI) system that provides automated measurements and reviewable anatomical landmarks. Methods: This single-center retrospective study used 240 training, 80 validation, and 80 independent test radiographs, partitioned by patient. The test cohort included 80 patients (22 pediatric) and 160 limbs (44 pediatric). Six alignment angles were assessed against the mean of three measurements by an experienced deformity surgeon. Fully automated AI, unassisted physician workflows, and an AI-assisted resident workflow were compared using intraclass correlation coefficients (ICCs), mean absolute error (MAE), Bland–Altman analysis, and measurement time. Results: Fully automated AI achieved ICCs of 0.728–0.966 and MAEs of 0.52–1.26° across the six angles. In pediatric limbs, average-measure ICCs were 0.936–0.975 for five major alignment angles; the single-measure ICC for joint line convergence angle was 0.825. For the resident evaluated, AI-assisted MAEs were 0.57–1.41°, compared with 1.22–6.83° without assistance. Mean measurement time per radiograph was 2.7 ± 0.4 s for fully automated AI and 10.5 ± 3.4 s for physician-reviewed AI, compared with 77.9–100.5 s for unassisted physician workflows. Conclusions: The AI system provided angle-specific agreement with the expert reference and substantially faster measurement than unassisted workflows. Physician-supervised AI was associated with lower measurement error for the resident evaluated. The findings suggest potential utility as a physician-reviewed measurement aid. Pediatric results are encouraging and should be interpreted as descriptive evidence within the evaluated age range.