Chih-Yu Hsiao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chih-Yu Hsiao has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Chia-Yu Tang
Graduate Institute of Sports Training, University of Taipei, Taipei 111036, Taiwan
1 shared publication - Fu-Shun Hsu
Department of Exercise and Health Sciences, University of Taipei, Taipei 111036, Taiwan
1 shared publication - Jing-Hsuan Chen
Graduate Institute of Sports Training, University of Taipei, Taipei 111036, Taiwan
1 shared publication - Jing-Jie Lin
Department of Exercise and Health Sciences, University of Taipei, Taipei 111036, Taiwan
1 shared publication - Szu-Kai Fu
Department of Exercise and Health Sciences, University of Taipei, Taipei 111036, Taiwan
1 shared publication - Yuh-Chuan Shih
Department of Logistics Management, National Defense University, Taipei 112305, Taiwan
1 shared publication
Latest Publications
- Open Access
MET-Based Intensity Classification Across Predefined Workload Conditions and Environmental Temperatures While Wearing Chemical Protective Clothing
Chemical protective clothing may increase metabolic demands during occupational tasks. This study examined metabolic demands and metabolic equivalent of task (MET)-based intensity classifications across predefined workload conditions and environmental temperatures while participants wore NPS-108 chemical protective clothing. Fifteen male participants completed 27 trials comprising three temperatures (15, 25, and 35 °C; 70% relative humidity) and nine workload conditions combining external loads (0, 10, and 20 kg) with locomotion speeds (4, 6, and 8 km/h). Metabolic responses during 15 min of treadmill locomotion were measured using a COSMED K5 portable metabolic system and analyzed using a two-way repeated-measures analysis of variance with pairwise comparisons. Intensity was classified based on group mean MET values. All conditions at 4 km/h were moderate intensity (3.8–5.3 METs), and all conditions at 8 km/h were vigorous intensity (9.0–12.8 METs). At 6 km/h, the no-load condition was moderate at 15 °C but vigorous at 25 °C and 35 °C, whereas both loaded conditions were vigorous at all temperatures. The repeated-measures ANOVA identified main effects of temperature and workload condition and a temperature-by-workload-condition interaction. After Bonferroni adjustment, MET values at 15 °C were lower than those at 35 °C in all nine workload conditions and lower than those at 25 °C in six conditions; 25 °C and 35 °C differed in one condition. These findings provide a practical reference for comparing the metabolic intensity of the tested workload conditions and may assist in planning training and occupational tasks performed in chemical protective clothing.
Open AccessMET-Based Intensity Classification Across Predefined Workload Conditions and Environmental Temperatures While Wearing Chemical Protective Clothing
Chemical protective clothing may increase metabolic demands during occupational tasks. This study examined metabolic demands and metabolic equivalent of task (MET)-based intensity classifications across predefined workload conditions and environmental temperatures while participants wore NPS-108 chemical protective clothing. Fifteen male participants completed 27 trials comprising three temperatures (15, 25, and 35 °C; 70% relative humidity) and nine workload conditions combining external loads (0, 10, and 20 kg) with locomotion speeds (4, 6, and 8 km/h). Metabolic responses during 15 min of treadmill locomotion were measured using a COSMED K5 portable metabolic system and analyzed using a two-way repeated-measures analysis of variance with pairwise comparisons. Intensity was classified based on group mean MET values. All conditions at 4 km/h were moderate intensity (3.8–5.3 METs), and all conditions at 8 km/h were vigorous intensity (9.0–12.8 METs). At 6 km/h, the no-load condition was moderate at 15 °C but vigorous at 25 °C and 35 °C, whereas both loaded conditions were vigorous at all temperatures. The repeated-measures ANOVA identified main effects of temperature and workload condition and a temperature-by-workload-condition interaction. After Bonferroni adjustment, MET values at 15 °C were lower than those at 35 °C in all nine workload conditions and lower than those at 25 °C in six conditions; 25 °C and 35 °C differed in one condition. These findings provide a practical reference for comparing the metabolic intensity of the tested workload conditions and may assist in planning training and occupational tasks performed in chemical protective clothing.