Joana Maria Huertas‐Pons
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Joana Maria Huertas‐Pons has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Alexis García-Sarreón
Multiple Sclerosis and Neuroimmunology Unit, Neurology Department, Doctor Josep Trueta University Hospital, Girona, Spain
1 shared publication - Almudena Boix-Lago
Neuroimmunology and Multiple Sclerosis Unit, Hospital Universitari de Girona Doctor Josep Trueta Servei de Neurologia, Girona, Spain
1 shared publication - Alèxia Pardiñas Ramon
Neurodegeneration and Neuroinflammation Research Group Girona Biomedical Research Institute (IDIBGI‐CERCA) Salt Spain
1 shared publication - Ariadna Gifreu-Fraixinó
Neuroimmunology and Multiple Sclerosis Unit, Hospital Universitari de Girona Doctor Josep Trueta Servei de Neurologia, Girona, Spain
1 shared publication Carmen Martínez Follana
Neurology Department Dr. Josep Trueta University Hospital Girona Spain
1 shared publicationElena Massa Gómez
Clinical Laboratory Service Laboratori Clínic Territorial De Girona Girona Spain
1 shared publication
Latest Publications
- Open Access
- 23 November 2026
- Published by Wiley in Brain and Behavior
- Vol. 16 (11)
Neural Antibody Testing in Autoimmune and Paraneoplastic Neurological Disorders: Diagnostic Performance and Pre‐Test Probability in a Consecutive Catchment‐Based Cohort
Background: Neural antibody testing is increasingly used in suspected autoimmune encephalitis (AE) and paraneoplastic neurological syndromes (PNS), but its diagnostic value in routine practice depends on pre‐test probability and specimen strategy. We evaluated its diagnostic performance and the catchment‐referenced rate of reference‐standard autoimmune and paraneoplastic neurological disorders. Methods: We conducted a retrospective cohort study of consecutive patients who underwent neural antibody testing between 2020 and 2023 within a tertiary referral network serving approximately 900,000 inhabitants. The reference standard was established through retrospective review of the available clinical records, applying the 2016 Graus criteria for AE and the 2021 PNS‐Care criteria for PNS. Phenotype‐concordant antibody‐associated neurological disorders not adequately covered by these criteria were also included. Results: Among 219 tested patients, 20 met the reference standard (catchment‐referenced annual rate, 0.56 per 100,000 inhabitants). At the patient level, index antibody testing yielded 9 true‐positive, 1 false‐positive, 11 false‐negative and 198 true‐negative results, corresponding to a sensitivity of 45.0%, specificity of 99.5%, PPV of 90.0%, and NPV of 94.7%. The true‐positive diagnostic yield was 4.1%. No reference‐standard cases occurred in the low pre‐test probability group. Sensitivity was 53.3% with paired serum–CSF testing and 20.0% with serum‐only testing, although subgroup estimates were imprecise. Conclusions: In routine neurological practice, index antibody testing showed high specificity but limited sensitivity against the clinical reference standard. These findings are consistent with a phenotype‐guided, confirmatory role for neural antibody testing, suggest potential value of paired serum–CSF sampling when clinical suspicion is higher, and emphasize that negative results should be interpreted in the broader clinical and paraclinical context.
- 23 November 2026
- Published by Wiley in Brain and Behavior
- Vol. 16 (11)
Open AccessNeural Antibody Testing in Autoimmune and Paraneoplastic Neurological Disorders: Diagnostic Performance and Pre‐Test Probability in a Consecutive Catchment‐Based Cohort
Background: Neural antibody testing is increasingly used in suspected autoimmune encephalitis (AE) and paraneoplastic neurological syndromes (PNS), but its diagnostic value in routine practice depends on pre‐test probability and specimen strategy. We evaluated its diagnostic performance and the catchment‐referenced rate of reference‐standard autoimmune and paraneoplastic neurological disorders. Methods: We conducted a retrospective cohort study of consecutive patients who underwent neural antibody testing between 2020 and 2023 within a tertiary referral network serving approximately 900,000 inhabitants. The reference standard was established through retrospective review of the available clinical records, applying the 2016 Graus criteria for AE and the 2021 PNS‐Care criteria for PNS. Phenotype‐concordant antibody‐associated neurological disorders not adequately covered by these criteria were also included. Results: Among 219 tested patients, 20 met the reference standard (catchment‐referenced annual rate, 0.56 per 100,000 inhabitants). At the patient level, index antibody testing yielded 9 true‐positive, 1 false‐positive, 11 false‐negative and 198 true‐negative results, corresponding to a sensitivity of 45.0%, specificity of 99.5%, PPV of 90.0%, and NPV of 94.7%. The true‐positive diagnostic yield was 4.1%. No reference‐standard cases occurred in the low pre‐test probability group. Sensitivity was 53.3% with paired serum–CSF testing and 20.0% with serum‐only testing, although subgroup estimates were imprecise. Conclusions: In routine neurological practice, index antibody testing showed high specificity but limited sensitivity against the clinical reference standard. These findings are consistent with a phenotype‐guided, confirmatory role for neural antibody testing, suggest potential value of paired serum–CSF sampling when clinical suspicion is higher, and emphasize that negative results should be interpreted in the broader clinical and paraclinical context.