Kabir Khanuja
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kabir Khanuja has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Kavya Bhand
Vishwakarma Institute of Technology, India
1 shared publication - Pranav Rana
Vishwakarma Institute of Technology, India
1 shared publication - Shilpa Katikar
Vishwakarma Institute of Technology, India
1 shared publication
Latest Publications
- Open Access
- 24 November 2026
- Published by MDPI AG in Preprints.org
Arogya: Interpretable Joint-Angle Templates for Camera-Based Assessment of Home Rehabilitation Exercises
Home exercise programmes are central to rehabilitation, but patients mostly perform them unsupervised, and clinicians learn little about how the exercises were actually done. We present Arogya, a camera-only home rehabilitation system in which each exercise is described by a template of named joint-angle ranges that a physiotherapist can read and adjust for an individual patient. A repetition is scored by how far its measured angles fall outside those ranges, so every warning refers to a specific joint and a specific size of deviation. We evaluated the measurement and decision stages on the public REHAB24-6 dataset (10 participants, six exercises, 1,057 labelled repetitions), using MediaPipe Pose on ordinary RGB video and synchronised optical motion capture as the reference. Repetition-level trunk, hip and knee angles agreed with motion capture with mean absolute errors of 5.1°, 8.9° and 10.8° (r = 0.88–0.94). Elbow angles were less reliable (20.9°), and a camera at half-profile gave the best agreement for most angles. In leave-one-subject-out evaluation, the templates detected incorrect repetitions with a mean balanced accuracy of 0.58 (AUC 0.62). The same templates reached 0.60 on motion-capture angles, and a random forest trained on the same features reached 0.63. Pose estimation and template evaluation together ran at 25 frames per second on four CPU cores. For this task a single camera comes close to motion capture; the main limitation is what joint-angle extremes can express. We discuss what this implies for per-patient, clinician-set criteria.
- 24 November 2026
- Published by MDPI AG in Preprints.org
Open AccessArogya: Interpretable Joint-Angle Templates for Camera-Based Assessment of Home Rehabilitation Exercises
Home exercise programmes are central to rehabilitation, but patients mostly perform them unsupervised, and clinicians learn little about how the exercises were actually done. We present Arogya, a camera-only home rehabilitation system in which each exercise is described by a template of named joint-angle ranges that a physiotherapist can read and adjust for an individual patient. A repetition is scored by how far its measured angles fall outside those ranges, so every warning refers to a specific joint and a specific size of deviation. We evaluated the measurement and decision stages on the public REHAB24-6 dataset (10 participants, six exercises, 1,057 labelled repetitions), using MediaPipe Pose on ordinary RGB video and synchronised optical motion capture as the reference. Repetition-level trunk, hip and knee angles agreed with motion capture with mean absolute errors of 5.1°, 8.9° and 10.8° (r = 0.88–0.94). Elbow angles were less reliable (20.9°), and a camera at half-profile gave the best agreement for most angles. In leave-one-subject-out evaluation, the templates detected incorrect repetitions with a mean balanced accuracy of 0.58 (AUC 0.62). The same templates reached 0.60 on motion-capture angles, and a random forest trained on the same features reached 0.63. Pose estimation and template evaluation together ran at 25 frames per second on four CPU cores. For this task a single camera comes close to motion capture; the main limitation is what joint-angle extremes can express. We discuss what this implies for per-patient, clinician-set criteria.