Chen Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chen Li has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Baoyun Qiu
College of Electrical, Energy and Power Engineering, Yangzhou University, Yangzhou 225127, China
1 shared publication - Guipeng Qi
College of Hydraulic Science and Engineering, Yangzhou University, Yangzhou 225009, China
1 shared publication - Huijie Wang
College of Electrical and Automotive Engineering, Yangzhou Polytechnic University, Yangzhou 225009, China
1 shared publication - Lihua Qian
Jiangsu Jiangdu Water Conservancy Engineering Management Office, Yangzhou 225200, China
1 shared publication - Tianxu Yan
College of Electrical, Energy and Power Engineering, Yangzhou University, Yangzhou 225127, China
1 shared publication - Yuyang Che
Jiangsu Surveying and Design Institute of Water Resources Co., Ltd., Yangzhou 225127, China
1 shared publication
Latest Publications
- Open Access
Optimal Variable-Angle Operation and Blade Adjustment Force Analysis for a Large Low-Head Vertical Axial-Flow Pump System
Large low-head pumping stations are critical for water transfer and irrigation, but their blade adjustment mechanisms suffer from deformation and damage during variable-angle operation, impairing control accuracy and system reliability. This study investigates a centralized hydraulic blade adjustment mechanism to improve variable-angle precision and reliability. The blade angle–head function at maximum efficiency was fitted from performance curves. Numerical simulations of 25 operating conditions were conducted using the k-ε model with hydrostatic pressure boundaries specified from the measured upstream and downstream water levels to calculate the hydraulic torque on the blades about the blade shaft. A method based on no-load oil-pressure measurements was proposed to determine friction and self-weight. The predicted adjustment forces were validated against field measurements at a pump-system head of 1.08 m over five blade angles. For upward adjustment, the mean relative error was 3.00%; for downward adjustment, larger relative deviations occurred in the low-force range, mainly due to the small baseline force. According to the fitted performance curves, variable-angle operation increases efficiency by 5.31 percentage points at a head of 1.5 m. The numerical results show that the adjustment force is dominated by hydraulic torque, with head as the primary factor, followed by blade angle; the maximum absolute adjustment force is 259,974.19 N. A numerical design analysis further predicts that lengthening the rocker arm can reduce the adjustment force by up to 20.16%. This study can provide a reference for variable-angle operation of large low-head pumping stations and structural optimization design of blade adjustment mechanisms.
Open AccessOptimal Variable-Angle Operation and Blade Adjustment Force Analysis for a Large Low-Head Vertical Axial-Flow Pump System
Large low-head pumping stations are critical for water transfer and irrigation, but their blade adjustment mechanisms suffer from deformation and damage during variable-angle operation, impairing control accuracy and system reliability. This study investigates a centralized hydraulic blade adjustment mechanism to improve variable-angle precision and reliability. The blade angle–head function at maximum efficiency was fitted from performance curves. Numerical simulations of 25 operating conditions were conducted using the k-ε model with hydrostatic pressure boundaries specified from the measured upstream and downstream water levels to calculate the hydraulic torque on the blades about the blade shaft. A method based on no-load oil-pressure measurements was proposed to determine friction and self-weight. The predicted adjustment forces were validated against field measurements at a pump-system head of 1.08 m over five blade angles. For upward adjustment, the mean relative error was 3.00%; for downward adjustment, larger relative deviations occurred in the low-force range, mainly due to the small baseline force. According to the fitted performance curves, variable-angle operation increases efficiency by 5.31 percentage points at a head of 1.5 m. The numerical results show that the adjustment force is dominated by hydraulic torque, with head as the primary factor, followed by blade angle; the maximum absolute adjustment force is 259,974.19 N. A numerical design analysis further predicts that lengthening the rocker arm can reduce the adjustment force by up to 20.16%. This study can provide a reference for variable-angle operation of large low-head pumping stations and structural optimization design of blade adjustment mechanisms.