ShiuanCheng Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
ShiuanCheng Wang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- YungChang Yang
Department of Safety, Health and Environmental Engineering, National Kaohsiung First University of Science and Technology, No. 1, Daxue Rd., Yanchao Dist., Kaohsiung City, 82445 Taiwan
2 shared publications ChiaYuan Shih
National Kaohsiung University of Science and Technology, Kaohsiung, Taiwan, and Tainan City Government Fire Bureau, Tainan City, Taiwan
1 shared publication- ChiaYuan Shih
Department of Safety, Health and Environmental Engineering, National Kaohsiung First University of Science and Technology, No. 1, Daxue Rd., Yanchao Dist., Kaohsiung City, 82445 Taiwan
1 shared publication - ChungHwei Su
Department of Safety, Health and Environmental Engineering, National Kaohsiung First University of Science and Technology, Kaohsiung City, 82445, Taiwan
1 shared publication - ChungHwei Su
Department of Safety, Health and Environmental Engineering, National Kaohsiung University of Science and Technology, Kaohsiung City, Taiwan
1 shared publication - YaoHan Chen1 shared publication
Latest Publications
- 7 January 2019
- Published by Emerald Publishing in International Journal of Numerical Methods for Heat & Fluid Flow
- Vol. 29 (1) , 309-333
Analysis of makeup air in a natural smoke vent system in a tall space using numerical simulation and Schlieren technique
Purpose: The purpose of this paper is to analyze the phenomenon of makeup effect using numerical simulation and model experiments on seven different natural smoke extraction patterns of tall space. Airflow distribution and heat accumulation phenomenon in different cases are compared. The natural smoke exhaust system for tall spaces has many advantages, including low cost, no power and low maintenance cost. It is more advantageous than the mechanical type of exhaust. However, the internal air distribution is complicated since the large span spatial character. Effective and correct verification method is very important for the analysis of flow fields in tall spaces. Design/methodology/approach: This study used fire dynamics simulator (FDS) software to simulate the fire scene. The model experiments are conducted to determine if the numerical simulation results are reasonable. A single-mirror Schlieren system, including an 838 (H) × 736 mm (W) square concave mirror, as well as the focal length of 3,100 mm was adopted to record the dynamic flow of hot gas. Six smokeless candles were burned in a 1/12.5 model in experiments to record the distribution of inflow, accumulation and outflow of airflow in the space. In addition, the thermocouple lines were mounted in the model for temperature measurement. Findings: The results of numerical simulation and model experiments have proved that makeup air has a significant effect on the effectiveness of a natural smoke vent system. Larger areas of smoke vents will produce more heat accumulation phenomenon. In this study, the air inlet and vent installed on the same side have a better heat removal effect. Moreover, Schlieren photography technique is proved to be an accurate measurement method to record the dynamic flow of hot air immediately, directly and accurately. The dynamic flow behavior of hot gas in the model has been visualized in this paper. Originality/value: At present, there is no examination method other than checking the smoke vent area to validate the effectiveness of a natural smoke vent system in Taiwan, as well as no requirements regarding the makeup inlet. The effect of makeup air in generating the effective push-pull phenomenon of airflow has been analyzed. In addition, the post-combustion hot gas distributions were visualized by using Schlieren photography technology in the model space, compared with the FDS simulation result and thermocouple recorded temperature. A verification method in the model experiments is established to determine if the numerical simulation results are reasonable.
- 7 January 2019
- Published by Emerald Publishing in International Journal of Numerical Methods for Heat & Fluid Flow
- Vol. 29 (1) , 309-333
Analysis of makeup air in a natural smoke vent system in a tall space using numerical simulation and Schlieren technique
Purpose: The purpose of this paper is to analyze the phenomenon of makeup effect using numerical simulation and model experiments on seven different natural smoke extraction patterns of tall space. Airflow distribution and heat accumulation phenomenon in different cases are compared. The natural smoke exhaust system for tall spaces has many advantages, including low cost, no power and low maintenance cost. It is more advantageous than the mechanical type of exhaust. However, the internal air distribution is complicated since the large span spatial character. Effective and correct verification method is very important for the analysis of flow fields in tall spaces. Design/methodology/approach: This study used fire dynamics simulator (FDS) software to simulate the fire scene. The model experiments are conducted to determine if the numerical simulation results are reasonable. A single-mirror Schlieren system, including an 838 (H) × 736 mm (W) square concave mirror, as well as the focal length of 3,100 mm was adopted to record the dynamic flow of hot gas. Six smokeless candles were burned in a 1/12.5 model in experiments to record the distribution of inflow, accumulation and outflow of airflow in the space. In addition, the thermocouple lines were mounted in the model for temperature measurement. Findings: The results of numerical simulation and model experiments have proved that makeup air has a significant effect on the effectiveness of a natural smoke vent system. Larger areas of smoke vents will produce more heat accumulation phenomenon. In this study, the air inlet and vent installed on the same side have a better heat removal effect. Moreover, Schlieren photography technique is proved to be an accurate measurement method to record the dynamic flow of hot air immediately, directly and accurately. The dynamic flow behavior of hot gas in the model has been visualized in this paper. Originality/value: At present, there is no examination method other than checking the smoke vent area to validate the effectiveness of a natural smoke vent system in Taiwan, as well as no requirements regarding the makeup inlet. The effect of makeup air in generating the effective push-pull phenomenon of airflow has been analyzed. In addition, the post-combustion hot gas distributions were visualized by using Schlieren photography technology in the model space, compared with the FDS simulation result and thermocouple recorded temperature. A verification method in the model experiments is established to determine if the numerical simulation results are reasonable.
- Open Access
- 7 October 2016
- Published by Springer Nature in SpringerPlus
- Vol. 5 (1) , 1-18
Visualization of hot flows of tall space fires in model experiments with Schlieren Photography technique
The natural smoke exhaust system for tall spaces is more advantageous than the mechanical type of exhaust. In Taiwan, the effectiveness of natural smoke exhaust systems is inspected only by checking the vent area size. However, the air flow field in a tall space is very complicated, both at ordinary times or during fires. This study used Schlieren Photography technique, on the principle that light rays are refracted when penetrating materials of different densities, to test and simulate the dynamic measurement of hot air in tall space model. A single-mirror Schlieren system, including an 838 mm (H) × 736 mm (W) square concave mirror, as well as the focal length of 3100 mm was adopted. The experimental process of six smokeless candles were used for 1/12.5 model experiment to record the dynamic distribution and accumulation of air flow in the abovementioned space. FDS software was used to simulate various fire scenarios. The different locations of openings in some cases were studied with the maximum temperature scales of 40 and 45 °C, separately. The simulation results and experimental images showed highly similar hot air flow patterns. Schlieren Photography was proved capable of recording and visualizing the dynamic flow of hot air immediately, directly and accurately.
- 7 October 2016
- Published by Springer Nature in SpringerPlus
- Vol. 5 (1) , 1-18
Open AccessVisualization of hot flows of tall space fires in model experiments with Schlieren Photography technique
The natural smoke exhaust system for tall spaces is more advantageous than the mechanical type of exhaust. In Taiwan, the effectiveness of natural smoke exhaust systems is inspected only by checking the vent area size. However, the air flow field in a tall space is very complicated, both at ordinary times or during fires. This study used Schlieren Photography technique, on the principle that light rays are refracted when penetrating materials of different densities, to test and simulate the dynamic measurement of hot air in tall space model. A single-mirror Schlieren system, including an 838 mm (H) × 736 mm (W) square concave mirror, as well as the focal length of 3100 mm was adopted. The experimental process of six smokeless candles were used for 1/12.5 model experiment to record the dynamic distribution and accumulation of air flow in the abovementioned space. FDS software was used to simulate various fire scenarios. The different locations of openings in some cases were studied with the maximum temperature scales of 40 and 45 °C, separately. The simulation results and experimental images showed highly similar hot air flow patterns. Schlieren Photography was proved capable of recording and visualizing the dynamic flow of hot air immediately, directly and accurately.