SHSeong Jong Hong

Seong Jong Hong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Seong Jong Hong has a total of 533 co-authors. Here are the top co-authors by number of shared publications:

  • Han Gyu Kang

    Department of Nuclear Medicine Science, National Institutes for Quantum and Radiological Science and Technology National Institute of Radiological Sciences, Imaging Physics Group, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba Japan, Chiba, Chiba, 263-8555, JAPAN

    10 shared publications
  • Young Been Han

    Department of Senior Healthcare, Graduate School, Eulji University, Daejeon 34824, Republic of Korea

    5 shared publications
  • Seong Hyun Song

    Department of Senior Healthcare, Graduate School, Eulji University, Daejeon 34824, Republic of Korea

    4 shared publications
  • Ho-Young Lee

    Department of Nuclear Medicine, College of Medicine Seoul National University, Seoul 13620, Republic of Korea

    3 shared publications
  • J.T. Rhee

    Department of Physics, Konkuk University, 120 Hyayang-Dong, Gwangjin-Gu, Seoul, 143-701, Republic of Korea

    3 shared publications
  • Kyeong Min Kim

    Department of Radiation Equipment, Korea Institute of Radiological and Medical Sciences, Seoul 01812, South Korea

    3 shared publications

Latest Publications

  • Multimodal laparoscopic coincidence gamma imaging system for near-infrared fluorescence guided surgery: a preclinical study

    by Seong Hyun Song, Seong Jong Hong, Ho Young Lee, Han Gyu Kang, Young Been Han

    PurposeMinimally invasive surgery has advantages in terms of quality of life and patient outcomes. Recently, near-infrared (NIR) fluorescence guided surgery has widely used for preclinical and clinical trials. However, NIR fluorescence has a maximum penetration capability of 10 mm. Radiographic imaging can be a solution to overcome the depth issue of NIR fluorescence. For this reason, the performance of the multimodal imaging system, which integrates annihilation gamma (511 keV) rays, NIR fluorescence, and color images, was evaluated.ApproachThe multimodal imaging system consisted of a laparoscopic module, containing an internal detector for annihilation gamma events and cameras for optical imaging, and a flat module for coincidence detection with the internal detector. The acquired images were integrated by an algorithm with post image processing and registration. To evaluate the performance of the proposed multimodal imaging system, the images of a resolution target, a square bar target filled with a fluorescence dye, and a sodium-22 point source were analyzed. A preclinical test for axillary sentinel lymph node (SLN) biopsy with a rat model was conducted.ResultsThe spatial resolution of color images was equivalent to 4 lp/mm. The modulation transfer function of NIR fluorescence at 1 lp/mm was 0.83. The 511 keV gamma sensitivity and spatial resolution of the point source were 0.54 cps/kBq and 2.1 mm, respectively. The image of 511 keV gamma rays showed almost the same intensity regardless of the thickness of the tissue phantom. In the preclinical test, an integrated image of the SLN sample of the rat model was obtained with the proposed multimodal imaging system.ConclusionsWith the proposed laparoscopic system, a merged image of the sample was obtained with the rat model. The annihilation gamma rays showed penetration capability with the tissue-mimicking phantom superior to that of NIR fluorescence.


  • Open Access

    SiPM-based gamma detector with a central GRIN lens for a visible/NIRF/gamma multi-modal laparoscope

    by Young Been Han, Seong Hyun Song, Han Gyu Kang, Ho-Young Lee, Seong Jong Hong

    Intraoperative imaging has been studied using conventional devices such as near infrared (NIR) optical probes and gamma probes. However, these devices have limited depth penetration and spatial resolution. In a previous study, we realized a multi-modal endoscopic system. However, charge-coupled device (CCD)-based gamma imaging required long acquisition times and lacked gamma energy information. A silicon photomultiplier (SiPM)-based gamma detector is implemented in a multi-modal laparoscope herein. A gradient index (GRIN) lens and CCD are used to transfer and readout visible and NIR photons. The feasibility of in-vivo sentinel lymph node (SLN) mapping was successfully performed with the proposed system.


  • Crystal surface and reflector optimization for the SiPM-based dual-ended readout TOF-DOI PET detector

    by Han Gyu Kang, Taiga Yamaya, Young Been Han, Seong Hyun Song, Guen Bae Ko, Jae Sung Lee, Seong Jong Hong

    Silicon photomultipliers (SiPMs) are now widely used for positron emission tomography (PET) applications because of their high gain and low noise characteristics. The PET image quality has been improved with the advancement of time-of-flight (TOF) and depth-of-interaction (DOI) measurement techniques. For brain-dedicated PET systems, both TOF and DOI information are beneficial for enhancing the reconstructed PET image quality. In a previous study, we proposed SiPM-based dual-ended readout PET detectors that used a mean time method to achieve coincidence timing resolution (CTR) of 349 ps and DOI resolution of 2.9 mm. However, the coincidence timing resolution (CTR) was worse than 300 ps since the crystal surface and the reflector type were not optimized. This study aimed at investigating the optimal crystal surface treatment and the reflector material to achieve a sub-200 ps CTR and sub-3 mm DOI resolution with a dual-ended readout PET detector using an LYSO crystal (2.9 × 2.9 × 20 mm 3 ). The scintillation light inside the LYSO crystal was read out by two SiPMs using the dual-ended readout method. The CTR and DOI resolution were measured with two different crystal surfaces (polished and saw-cut) and three different reflector material scenarios of ESR without grease (i.e., air coupling), ESR with optical grease and Teflon. We digitized the timing and energy signals by using a V775N TDC module (35 ps bit −1 ) and V965 QDC module, respectively. The combination of the saw-cut LYSO crystal and the ESR with air coupling resulted in the best CTR (188 ± 32 ps) and DOI resolution (2.9 ± 0.2 mm) with the dual-ended readout configuration. We concluded the dual-ended readout method in combination with the saw-cut crystal and the ESR reflector with air coupling can provide a sub-200 ps CTR and sub-3.0 mm DOI resolution simultaneously.


  • Open Access

    Characterization and validation of multimodal annihilation-gamma/near-infrared/visible laparoscopic system

    by Seong Hyun Song, Han Gyu Kang, Young Been Han, Ho-Young Lee, Dae-Hong Jeong, Soo Mee Kim, Seong Jong Hong

    Compared to conventional open surgery, which utilizes images acquired before the surgery from computed tomography (CT), magnetic resonance imaging (MRI), positron emission tomography (PET), and other diagnostic modalities, minimally invasive robotic surgery (MIRS) has been widely used because of advantages such as less incision, fast recovery time, and the quality of patient care.1 – 3 Recently, near-infrared (NIR) image-guided surgeries have been used for the detection of sentinel lymph nodes (SLNs) and micro tumors during surgery, because these fluorescence systems provide relatively high sensitivity and superior resolution of <1  mm.4 – 7 They have also been used for colorectal, urological, and gynecological diseases to define the margin of the target to achieve minimal damage of the normal tissue and sensitive nerves. Among various fluorescence dyes for MIRS, a U.S. Food and Drug Administration-approved indocyanine green (ICG) dye with a peak emission wavelength of 820 nm has been used for SLN mapping and medical imaging for other lesions.8 – 12 However, the fluorescence has limited penetration depth (below 10 mm) because of its absorption and scattering in tissue such as skin, fat, and blood.13 – 15 For this reason, it is difficult to find SLNs or other target tissues covered with normal tissue. To overcome the depth limitation, multimodal imaging and hybrid methods have been used with radiation, ultrasound, and other compatible modalities. High-energy photons, such as x-rays and gamma rays, have relatively longer penetration depths despite radiation exposure, relatively low sensitivity, and poor spatial resolution.


  • SiPM-based dual-ended-readout DOI-TOF PET module based on mean-time method

    by Y.B. Han, H.G. Kang, S.H. Song, G.B. Ko, J.S. Lee, S.J. Hong


  • Open Access

    Proof-of-concept of a multimodal laparoscope for simultaneous NIR/gamma/visible imaging using wavelength division multiplexing

    by Han Gyu Kang, Seong Hyun Song, Young Been Han, Ho-Young Lee, Kyeong Min Kim, Seong Jong Hong

    An optical/nuclear hybrid surgical technique using ICG-99mTc-nanocolloid can improve lesion detectability by detecting both fluorescence and gamma signals. However, a hybrid multimodal laparoscope that can obtain both NIR and gamma images is not available yet. In this work, we present a proof-of-concept study of a prototype multimodal laparoscope that can provide simultaneous NIR/gamma/visible imaging using wavelength division multiplexing. The performances of optical and gamma imaging were evaluated using a USAF 1951 negative resolution target and 99mTc-filled tumor-like sources, respectively. Simultaneous NIR/gamma/visible images of two Eppendorf tubes containing a mixture of 99mTc-ICG are presented.


  • Lens implementation on the GATE Monte Carlo toolkit for optical imaging simulation

    by Han Gyu Kang, Seong Hyun Song, Young Been Han, Kyeong Min Kim, Seong Jong Hong

    Optical imaging techniques are widely used for in vivo preclinical studies, and it is well known that the Geant4 Application for Emission Tomography (GATE) can be employed for the Monte Carlo (MC) modeling of light transport inside heterogeneous tissues. However, the GATE MC toolkit is limited in that it does not yet include optical lens implementation, even though this is required for a more realistic optical imaging simulation. We describe our implementation of a biconvex lens into the GATE MC toolkit to improve both the sensitivity and spatial resolution for optical imaging simulation. The lens implemented into the GATE was validated against the ZEMAX optical simulation using an US air force 1951 resolution target. The ray diagrams and the charge-coupled device images of the GATE optical simulation agreed with the ZEMAX optical simulation results. In conclusion, the use of a lens on the GATE optical simulation could improve the image quality of bioluminescence and fluorescence significantly as compared with pinhole optics.


  • A feasibility study of an integrated NIR/gamma/visible imaging system for endoscopic sentinel lymph node mapping

    by Han Gyu Kang, Ho‐Young Lee, Kyeong Min Kim, Seong‐Hyun Song, Gun Chul Hong, Seong Jong Hong

    Purpose The aim of this study is to integrate NIR, gamma, and visible imaging tools into a single endoscopic system to overcome the limitation of NIR using gamma imaging and to demonstrate the feasibility of endoscopic NIR/gamma/visible fusion imaging for sentinel lymph node (SLN) mapping with a small animal. Methods The endoscopic NIR/gamma/visible imaging system consists of a tungsten pinhole collimator, a plastic focusing lens, a BGO crystal (11 × 11 × 2 mm3), a fiber-optic taper (front = 11 × 11 mm2, end = 4 × 4 mm2), a 122-cm long endoscopic fiber bundle, an NIR emission filter, a relay lens, and a CCD camera. A custom-made Derenzo-like phantom filled with a mixture of 99mTc and indocyanine green (ICG) was used to assess the spatial resolution of the NIR and gamma images. The ICG fluorophore was excited using a light-emitting diode (LED) with an excitation filter (723–758 nm), and the emitted fluorescence photons were detected with an emission filter (780–820 nm) for a duration of 100 ms. Subsequently, the 99mTc distribution in the phantom was imaged for 3 min. The feasibility of in vivo SLN mapping with a mouse was investigated by injecting a mixture of 99mTc-antimony sulfur colloid (12 MBq) and ICG (0.1 mL) into the right paw of the mouse (C57/B6) subcutaneously. After one hour, NIR, gamma, and visible images were acquired sequentially. Subsequently, the dissected SLN was imaged in the same way as the in vivo SLN mapping. Results The NIR, gamma, and visible images of the Derenzo-like phantom can be obtained with the proposed endoscopic imaging system. The NIR/gamma/visible fusion image of the SLN showed a good correlation among the NIR, gamma, and visible images both for the in vivo and ex vivo imaging. Conclusion We demonstrated the feasibility of the integrated NIR/gamma/visible imaging system using a single endoscopic fiber bundle. In future, we plan to investigate miniaturization of the endoscope head and simultaneous NIR/gamma/visible imaging with dichroic mirrors and three CCD cameras.


  • A Feasibility Study of a SiPM Based Intraoperative Beta Imaging/Gamma Probe using the Depth of Interaction Measurement

    by In-Suk Kwak, Han Gyu Kang, Jeong-Whan Son, Jae Sung Lee, Seong Jong Hong

    A Feasibility Study of a SiPM Based Intraoperative Beta Imaging/Gamma Probe using the Depth of Interaction Measurement Gamma detection;Intraoperative probe;Positron detection;Radionuclide guided surgery;Silicon photomultiplier (SiPM);Sentinel lymph node (SLN); Radiopharmaceutical agents for positron emission tomography (PET), such as $^{18}F$-FDG and $^{68}Ga$, have been used not only for whole-body PET imaging but also for intraoperative radionuclide-guided surgery due to their quantitative and sensitive imaging characteristics. Current intraoperative probes detect gamma or beta particles, but not both of them. Gamma probes have low sensitivities since a collimator has to be used to reduce backgrounds. Positron probes have a high tumor-to-background ratio, but they have a 1-2 mm depth limitation from the body surface. Most of current intraoperative probes produce only audible sounds proportional to count rates without providing tumor images. This research aims to detect both positrons and annihilation photons from $^{18}F$ using plastic scintillators and a GAGG scintillation crystal attached to silicon photomultiplier (SiPM). The depth-of-interaction (DOI) along the plastic scintillator can be used to obtain the 2-D images of tumors near the body surface. The front and rear part of the intraoperative probe consists of $4{\times}1$ plastic scintillators ($2.9{\times}2.0{\times}12.0mm^3$) for positron detection and a Ce:GAGG scintillation crystal ($12.0{\times}12.0{\times}9.0mm^3$) for annihilation photon detection, respectively. The DOI resolution of $4.4{\pm}1.6mm$ along the plastic scintillator was obtained by using the 3M enhanced specular reflector (ESR) with rectangular holes between the plastic scintillators, which showed the feasibility of a 2-D image pixel size of $2.9{\times}4.4mm^2$ (X-direction ${\times}$ Y-direction).

  • Assessment of MR-compatibility of SiPM PET insert using short optical fiber bundles for small animal research

    by H.G. Kang, S.J. Hong, G.B. Ko, H.S. Yoon, I.C. Song, J.T. Rhee, J.S. Lee

    Simultaneous positron emission tomography (PET) and magnetic resonance imaging (MRI) can provide new perspectives in human disease research because of their complementary in-vivo imaging techniques. Previously, we have developed an MR-compatible PET insert based on optical fibers using silicon photomultipliers (SiPM). However when echo planar imaging (EPI) sequence was performed, signal intensity was slowly decreased by −0.9% over the 5.5 minutes and significant geometrical distortion was observed as the PET insert was installed inside an MRI bore, indicating that the PET electronics and its shielding boxes might have been too close to an MR imaging object. In this paper, optical fiber bundles with a length of 54 mm instead of 31 mm were employed to minimize PET interference on MR images. Furthermore, the LYSO crystals with a size of 1.5 × 1.5 × 7.0 mm3 were used instead of 2.47 × 2.74 × 20.0 mm3 for preclinical PET/MR applications. To improve the MR image quality, two receive-only loop coils were used. The effects of the PET insert on the SNR of the MR image either for morphological or advanced MR pulse sequences such as diffusion weighted imaging (DWI), functional MRI (fMRI), and magnetic resonance spectroscopy (MRS) were investigated. The quantitative MR compatibility such as B0 and B1 field homogeneity without PET, with `PET OFF', and with `PET ON' was also evaluated. In conclusion, B0 maps were not affected by the proposed PET insert whereas B1 maps were significantly affected by the PET insert. The advanced MRI sequences such as DWI, EPI, and MRS can be performed without a significant MR image quality degradation.