Zheng Feng Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zheng Feng Lu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Charles Shen
Advanced ConsTruction and Information techNology (ACTION) Laboratory, Columbia University, New York, NY 10027 USA
1 shared publication Feniosky Peña-Mora
Department of Civil Engineering & Engineering Mechanics, Columbia University, 500 West 120th Street, New York, NY 10027
1 shared publicationJames Mok
Spine Surgery, DuPage Medical Group, Downers Grove, Illinois, USA
1 shared publication- Nisa Cem Oren
Faculty of Medicine, Department of Radiology, University of Chicago, Chicago, USA
1 shared publication - Saad Ali
Radiology, University of Chicago Medical Center, Chicago, Illinois, USA
1 shared publication - Seon-Kyu Lee
Radiology, Montefiore Hospital and Medical Center, Bronx, New York, USA
1 shared publication
Latest Publications
- 18 January 2021
- Published by Wiley in International Journal of Energy Research
- Vol. 45 (6) , 9141-9161
Performance prediction of fuel cells using long short‐term memory recurrent neural network
- 18 January 2021
- Published by Wiley in International Journal of Energy Research
- Vol. 45 (6) , 9141-9161
Performance prediction of fuel cells using long short‐term memory recurrent neural network
- 17 June 2020
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 13 (2) , 191-195
Sacroiliac joint injections with the guidance of three-dimensional cone beam computed tomography (3D-CBCT) and fluoroscopy fusion
Background We describe our diagnostic sacroiliac joint (SIJ) injection technique under the guidance of three-dimensional cone beam computed tomography (3D-CBCT) fused with real-time fluoroscopy. Methods A retrospective review of 17 patients (mean age 55.4 (range 40–74) years) who received a total of 23 diagnostic SIJ injections between March 2016 and November 2017 were performed. Pre- and post-procedure pain scores were reviewed from the medical records and then these findings were correlated with which patients were and were not diagnosed with SIJ pain by clinical management. The final diagnosis of SIJ-related pain was made in cases with at least 50% symptomatic improvement following SIJ-specific pain treatments. Results Some 87% (n=20/23) of injections achieved more than 50% pain relief after the diagnostic SIJ injection. The final diagnosis of the target SIJ-related pain after follow-up and management was found in 90% (n=18/20) of cases. There were two cases with positive tests diagnosed as non-SIJ pain including one with the diagnosis of femuroacetabular impingement and one with pain related to loosening of knee hardware. The sensitivity, specificity, positive predictive value, and negative predicative value of diagnostic SIJ injections were 100%, 60%, 89%, and 100%, respectively, with a 40% false-positive rate. There were no procedure-related complications. Conclusion 3D-CBCT fused with real-time fluoroscopy for SIJ injection is accurate and safe.
- 17 June 2020
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 13 (2) , 191-195
Sacroiliac joint injections with the guidance of three-dimensional cone beam computed tomography (3D-CBCT) and fluoroscopy fusion
Background We describe our diagnostic sacroiliac joint (SIJ) injection technique under the guidance of three-dimensional cone beam computed tomography (3D-CBCT) fused with real-time fluoroscopy. Methods A retrospective review of 17 patients (mean age 55.4 (range 40–74) years) who received a total of 23 diagnostic SIJ injections between March 2016 and November 2017 were performed. Pre- and post-procedure pain scores were reviewed from the medical records and then these findings were correlated with which patients were and were not diagnosed with SIJ pain by clinical management. The final diagnosis of SIJ-related pain was made in cases with at least 50% symptomatic improvement following SIJ-specific pain treatments. Results Some 87% (n=20/23) of injections achieved more than 50% pain relief after the diagnostic SIJ injection. The final diagnosis of the target SIJ-related pain after follow-up and management was found in 90% (n=18/20) of cases. There were two cases with positive tests diagnosed as non-SIJ pain including one with the diagnosis of femuroacetabular impingement and one with pain related to loosening of knee hardware. The sensitivity, specificity, positive predictive value, and negative predicative value of diagnostic SIJ injections were 100%, 60%, 89%, and 100%, respectively, with a 40% false-positive rate. There were no procedure-related complications. Conclusion 3D-CBCT fused with real-time fluoroscopy for SIJ injection is accurate and safe.
- Open Access
- 1 January 2015
- Published by Elsevier in Procedia Engineering
- Vol. 123, 300-307
Social Impact Project Finance: An Innovative and Sustainable Infrastructure Financing Framework
- 1 January 2015
- Published by Elsevier in Procedia Engineering
- Vol. 123, 300-307
Open AccessSocial Impact Project Finance: An Innovative and Sustainable Infrastructure Financing Framework